background image

 

4.Specification 

4-1.General Feature 
● 4000 count LCD display. 
●   Auto ranges. 
 ● Over-rang indication display “OL” 
●Zener diode Test 
●LED Test 
●Battery Power Test 
●Specialized SMD TEST or TEST   

DIP Component with leade. 

 

● Low Batteery Indication 
● Power Supply: 1.5V(AAA

)×2

  Battery   

 
                      - 9 -   
  

5-2.Capacitance Measurement   
[1] Set the FUNCTION Switch at “R/D/C”, 
And press

 ‘FUNC’ button    until symbol of 

 

 is displayed on LCD. 

[2]

 

Connect the Test Pins to across the 

  Capacitance under measurement. 

[3] You can get reading from LCD. 
[4] When test low value of the capacitance

 

You can press "REL" Button to clear zero, 
then testing to obtain precist volue of the   
Capacitance. 

Caution 

To avoid damage to the Meter or to the  
equipment under test, disconnect power 
 and discharge all high-voltage capacitors 
 before measurement capacitance. 
When testing large capacitance, it will take 
longer  time  before  the  final  indication(For 
100uF , it will take about 15 seconds). 

                        - 13 - 

● Operating temperature &Humidity:0-40'C 
    (32-104'F) &<80%RH 
● Storage temperature & Humidity:-10-50 
● perating temperature &Humidity:0-4

0℃

 

(32-10

4℉

) &<80%RH 

● Safety Class:IEC1010-1,CAT 

 

● Auto Power OFF:lf the Meter is idle for 
    more than 15 minutes,the Meter 
    automatically tums the power off. 
● EMC:According to CE   regulation 
     89/336. 
● Dimension(L

×W×

H) & Weight: 206 X 

      36 X 25mm,Approx.50 g 
● Environmental condition: 
    (1) Indoor use; 
    (2) Altitude up to 2000meter. 
● Accessory: 

1. Spare Test Pin: 2PCS 

2. Special 

Test Leads: electric rating 500V 10A

 

                       

  - 10 - 

 
5-3 Diode Check 
[1] Set the FUNCTION Switch to “R/D/C”, 
And press

 „FUNC‟ button    until symbol of 

 

“ ”

 is displayed on LCD. 

[2]

 

Connect 'INPUT' Test Pin to the anode, 

and    Connect    'COM'    Test Pin to the 
cathode of the diode under testing

[3] You can get reading from LCD. 

A good silicon   junction   drop between  

0.5V-0.8V. 
5-4.Continuity Check 
[1] Set the FUNCTION Switch at “R/D/C”, 

And press „FUNC‟ button until symbol of

 

“   ” is displayed on LCD. 

[2]  Connect test pins across two points of 

    the circuit under testing.   

When the resistance reading is less than  
10~60 Ω, the buzzer generates 2KHz  

beep to indicate continuity. 
 

  

                          - 14 - 

4-2.Electrical Specification 

Function. 

Range 

Resolu 

-tion 

Accuracy 

Resistance  400

Ω

/4K

Ω

 

/40K/400K/ 
4M

Ω

 

40M

Ω

 

0.1

Ω

 

±

(2.0%rdg+5dgt) 

“ 

  “ 

±

(2.5rd%+5dgt) 

Capacitance  4nF/40nF/ 

400nF/4μF/ 
40μF/200μF 

1pF 

±

(2.5%rdg+5dgt) 

“ 

±

(3%rdg+5dgt) 

Diode Test  Open Voltage : 1.5V, Testing Current : 2mA 

Continuity 

Check 

When the resistance is less than   
approx.30

Ω

,The Buzzer is sounded. 

Zener/LED  Open Voltage :      MIN    20V,   

Testing Current :    Appr. 1mA 

BATTERY 

POWER 

Loading Current: 
Approx. 10mA 

±

(1.5rd%+5dgt) 

 
–11 – 

 
5-5. Zener or LED Check 
[1] Set the FUNCTION Switch to “

” 

[2]

 

Connect 'INPUT' Test Pin to the anode, 

and Connect    'COM'    Test Pin to the   

cathode of the ZENER/LED under testing

[3]The measured value  of  Zener  Voltage 

show on the LCD, Or show LED working 
Voltage on the LCD. 

5-7 Battery Power Measure 
[1] Set the FUNCTION Switch to “

” 

[2]

 

Connect 'INPUT' Test Pin to the anode, 

and Connect 'COM' Test Pin to the 

cathode of the Battery under testing

[3]The measured value of Battery Voltage   

at DC10mA load    show on the LCD,. 

6.Maintenance

 

  6-1.Replacing The Battery 
     When meter display

 ,the battery  

must  be replace to maintain nomal 

     operaion. 
 

                             

- 15 - 

5.Testing Operation 

 

Caution

 

when measuring SMD device on the PCB, 

you must be Disconnect power and discharge 

all high-voltage capacitors. 

 
5-1. Resistance Measurement 
[1] Set the FUNCTION Switch to “R/D/C”

 

[2]

 

Connect the Test Pins to across the 

  resistance under measurement. 

[3] You can get reading from LCD. 

[4] When test low value of the 

resistance, 

 

You can short two Test Pins, And Press 

  "REL" Button to clear zero, then testing   

to obtain volue of the resisitance. 

 

- 12 - 

 

  [1]

 

Open the battery cover on the bottom 

 case by pushing the battery cover. 

[2]

 

Remove old battery and put new two  

into battery holder. 
 

 

  Note:

 

     Battery type: 1.5V(AAA

)×2 

If you do not use    the meter a long 
time, pleseRemove the batteries from 
the

 meter. 

6-2.Cleaning     

The meter can be cleaned with soft clean  

cloth to remove any oil,grease or grim. 

    Do not use liquid solvent or detergent. 

 

Above  picture  and  content  just  for  your 
reference.  Please  be  subject  to  the  actual 
products  if  anything  different  or  updated. 
Please pardon for not informing in advance. 
                                - 16 - 

Reviews: