Warnings and Error Messages
11.7.1
Error Messages
Error messages are pop-up windows with the title
“
Error
” and
with a red background. In this case, the machine
or positioning cannot be started without first remedying the error.
Figure 45: Error message 1
Cause:
One of the existing emergency stop buttons is actuated.
Remedy:
Unlock the corresponding emergency stop button.
Figure 46: Error message 2
Cause:
There is a fault on the motor protection.
Remedy:
Check the motor protection switch and, if necessary,
the existing fuses and connections.
Figure 47: Error message 3
Cause:
A fault is present at the start/brake unit. This can be
triggered by thermal overload of the main motor or by
undervoltage.
Remedy:
Let the machine cool down and check all motor protec-
tion switches in the control cabinet. To reset the fault,
the machine must be restarted.
Figure 48: Error message 4
Cause:
The machine does not start because the feed switch is
turned to the “
ON
” position and the feed is active.
Remedy:
Turn the feed switch to the “
OFF
” position to be able to
start the machine.
Figure 49: Error message 5
Cause:
a) The fence is too far back
b) The hook-in tables are not mounted
Remedy:
a) Position the fence to the centre position
b) Mount both hook-in tables
Figure 50: Error message 6
Cause:
The selector switch (
28
), see
is set to the wrong position.
Remedy:
For planing & jointing operation, the selector
switch (
28
) must be turned to the
“
right
”
position.
Further (non-control-relevant) operating faults are described in the chapter