BA_PH_546-100_EN_06-22.docx
35
10.1.7
Calibrating the Planing Fence (Position 90°)
The angle of the fence should be checked regularly. If this is no longer exactly 90°, a calibration procedure is
necessary. To calibrate the fence to position 0 (
≙
90°), proceed as follows:
1.
Check the angle at the starting position 0 with a 90° stop angle (
W
) in the clamped state of lever (
24
)
(see
→
If the angle is not exactly 90°, it must be readjusted.
2.
To correct, open the clamping lever (
24
) and pull the adjusting lever (
25
) all the way forward (to 45° posi-
tion). Loosen the now accessible lock nut (
M
) with an open-end spanner SW13 (see
Figure 27). Then ad-
just the screw (
S
) either inwards or outwards (as required) until the angle is exactly 90° again (
3.
To check whether you are turning the in the right direction, push the adjustment lever (
25
) - as shown in
Figure 26 - all the way back with force (as far as it will go, the ruler must lift slightly). Then tighten the clamp-
ing lever (
24
) again. Repeat steps 1. and 2. until the angle is correct.
Note:
During adjustment, the lever (
25
) must always be moved fully forwards (towards the planing table) and
to check the angle, it must be moved backwards with force (so that the ruler lifts up slightly).
Figure 26: Check angle 90 degrees
Figure 27: Calibrate angle to 90 degrees
4.
Finally, tighten the clamping lever (24) again
→
The fence is now calibrated.
10.1.8
Calibrating the Planing Fence (Position 45°)
As with the 90° angle, it is also advisable to check the 45° angle regularly with a protractor and to calibrate it if
necessary. To adjust the 45° angle, proceed as follows:
1.
When the clamping lever (
24
) is open, move
the adjusting lever (
25
) forwards (towards
the planing table) (
→
Fence automatically folds to 45°.
2.
Check the 45° angle with a protractor.
3.
For readjustment, open the clamping lever
(
24
) and loosen the lock nut (
M
) with an
open-end spanner SW10. Then adjust the
angle using the grub screw (
S
) and an Allen
key SW3. Repeat steps 2. and 3. until the
angle is correct
Figure 28: Calibrate angle to 45 degrees
Note:
The clamping lever (
24
) must always be open during the adjustment of the screw and in the clamped
state during the angle check.
W
25
M
S
24
25
24
M
S
25