Chapter III Operation
Charging the Pods
The batteries used in the Portable Aligner Pods
are long life and do not require charging between
alignments. It is recommended to monitor the
battery condition LEDs and place them on the
charger when below 40% or when only two LEDs
are illuminated. In any case always place pods
on the charger at the end of the days work and
charge overnight.
To charge the Pods insert the connector of the
charge cord from the cabinet into the charge
receptacle on the side of the Pod.
It is OK if the Pods remain connected to the charge
cord after receiving a full charge.
The state of charge LEDs will begin flashing
indicating the level of charge.
As the Pods are discharged the LEDs will show
the amount of remaining charge as shown to the
left.
If only one LED is illuminated and flashing, less
than 10% power remains indicating the unit must
be charged.
Powering the Pods
Turn Pods On by momentarily depressing the On/
Off button.
Check battery charge by momentarily clicking the
on/off button.
Turn Pods Off by pressing and holding the On/Off
button for a few seconds until the LEDs go off.
NOTE: Pods should be turned off when
not in use.
WARNING!!!! Measuring Pods
utilize Lithium-Ion Batteries.
Should these Batteries ever
need replaced, only replace
with Factory Approved
Batteries designed for this purpose. Using
non-authorized batteries can create risks
including Fire. Replace with Battery Part
Number EAK0289J46A only.
Charge
cable from
cabinet
Page 3-26
10 to 20%
20 to 40%
40 to 60%
60 to 80%
80 to 100%
On/Off Button
State of Charge
Charge Receptacle