14
Item
number
(Figure 7)
Name
Control or
Indicator
Function
2
OK
Green LED
Indicates that sufficient oil is delivered
whether the well pump is on or off.
In the Normal (pump on) mode, this
corresponds to oil drip rates in excess of 15
dpm.
In the Pre-lube (pump off) mode, the LED
lights when the rate is between 1 and 15
dpm. The LED is off when a total lack of oil
condition occurs, and the
OIL
LED lights.
A corresponding relay contact closes when
the
OK
LED is on. The terminal for this
contact is called
O.K.
and appears in Figure 5
on page 9. This terminal can be used to
directly turn off the well pump in the Normal
(pump on) mode, when drip rates are less
than 15 dpm.
3
SB
Yellow LED
Lights in the Pre-lube (pump off) mode when
24 V DC/AC is applied to the S.B. terminals in
the connection box. The drip rate in this mode
is always 2 dpm.
4
DRIP
Yellow LED
This LED flashes whenever a drop passes
the photoelectric sensors in the Dripmaster
needle valve assembly (see Figure 11 on
page 21). In the Pre-lube (pump off) mode,
the DRIP LED flashes approximately every 30
seconds, indicating that oil is flowing to the
line shaft at a 2 dpm rate.
5
OPEN
Green LED
Lights when the motor is opening the valve.
6
Open Valve
SW16
Push button
Press to manually
open
the valve—for
troubleshooting, and can be used to shorten
the time to reach the preset drip rate.
7
UL
Yellow LED
Lights when the valve is completely open.
8
Control mode
SW17
Toggle switch
Select between manual and automatic
operation:
•
Manual (MAN): for
emergency
use only. In
this state, you can only open or close the
needle valve manually by pressing the
close valve or open valve push buttons.
•
Automatic (AUTO): the Dripmaster should
always be in this mode for full Dripmaster
functionality.
9
Manual Mode
Yellow LED
Lights in the manual mode—when the mode
switch (item 8) is in the up position
10
Close Valve
SW18
Push button
Press to manually
close
the valve—for
troubleshooting, and can be used to shorten
the time to reach the preset drip rate.