background image

HODAKA CO,. LTD.

1-6-17 Takadono, Asahi-ku, Osaka 533-31 Japan

tel +81-6-6922-5501 fax +81-6-6922-5895

e ‐ mail ; [email protected]

UPL ; http://www.hodaka-inc.co.jp

Flue gas analyzer HT-1200N

Operating Manual

ver.130101

Summary of Contents for HT-1200N

Page 1: ...KA CO LTD 1 6 17 Takadono Asahi ku Osaka 533 31 Japan tel 81 6 6922 5501 fax 81 6 6922 5895 e mail info hodaka inc co jp UPL http www hodaka inc co jp Flue gas analyzer HT 1200N Operating Manual ver 130101 ...

Page 2: ...er metal parts accessories are not to be used as electric conductors The device is not to be used in and under water The device is not to be placed near or directly at open fire or heat The indicated range of temperature of the probe is not to be exceeded as the probe temperature sensory mechanism and sensor could be destroyed Plugs of the electronic measuring device have to be avoided Caution Moi...

Page 3: ...t the connection plate the chargeing LED lights up On the display the current loading state of the battery is displayed If the battey is fully charged the HT 1200N changes to trickle charge and the LED blinks approx every 16 seconds The charging time for unloaded battery is approx 12 hours Attention No battery charge if the unit is switched ON measurement For battery charge the device has to be sw...

Page 4: ...er by means of Note the input soon munber and drivate is valid only at oil as fuel ESC ESC ESC or or or Input soot number in 1 steps Line transfer in line 1 Back to input T Boiler in line 4 Storage 6 2 Gas measurement Gas measurement View last values Zero setting Extension menu Programtype Program1 Program2 13A Wood LPG Keros 13A CO2 max 12 2 T Boiler Soot T Boiler 95 Soot1 2 Soot2 3 Soot3 1 oily ...

Page 5: ...ns of the the input of soot number and derivate follows with T Gas 120 1 O2 4 9 T Amb 24 3 Exc Air 1 31 Effic 95 0 Losses 5 0 7 Soot 1 2 Soot 2 3 Soot 3 1 oily negative Print Store Abort Stored data Device settings Service Set O2 alarm View stored data Delete data Measurem HT PC Store data Device settings Service Set O2 alarm Store data Device settings Service Set O2 alarm Store data Device settin...

Page 6: ...Select the function Start the function or Select the function Select the function Start the function or Start the function Current use of storage Select the function Start the function Data bloc was delete View stored data Delete data measurem HT PC Delete data NO Yes Stored data Device settings Service Set O2 alarm Set time and data Parameter Service menu Set time and data Parameter Service menu ...

Page 7: ...ber Yes Window Page 2 11 7 Calculation basis 7 1 Analysis and calculation Continuously measured items O2 Temperature Kthermocouple Temperature Pt 2000Ω Unit Unit Option Calculated measuring items CO2 Efficiency Losses Excess Air calcurated by ambient air temperature and flue gas temperature 12 Kcal Nm3 Kcal Nm3 Kcal Nm3 Kcal kg Kcal kg Kcal kg Kcal kg Kacl kg 13A 6C LPG Keros L oil A C Pellets 12 ...

Page 8: ... φ5 L 750mm φ6 L 750mm φ8 φ3 130L 0 950 for air liquid φ1 5 130L 0 950 for air liquid φ3 130L 0 400 for air liquid foods centric top 130L 0 400 for surface rifts air liquid φ4 130L 0 650 for surface rifts air liquid 0 450 magnetic probe for surface 0 180 Pliers probe for plates tube Probe handle Probe handle Probe tube for probe handle HT 7201G Probe tube with flue gase temp sensor 14 9 Storage 9 ...

Reviews: