Insufficient Unit Weight Indication
(
)
:
cursor appears on the bottom edge of UNIT
WEIGHT LCD (above of
S.W
printed on the
display-overlay), and indicates the averaging unit
weight is too light.
The internal resolution of this scale is 30000. While
the averaging unit weight of measured subjects is
lighter than “
max capacity
/
30000
”,
cursor will
flash on UNIT WEIGHT LCD. For example:
With 30kg max capacity; and the internal resolution
is 30000. 30kg / 30000 = 1g. If the averaging unit
weight of measured subjects is lighter than 1g,
cursor will flash on UNIT WEIGHT LCD (above of
S.W
printed on the display-overlay).
Operation Instructions
Status of the Battery :
When WEIGHT LCD indicates
and the scale
sounds
beep beep beep
every thirty-minute, it
means the battery is running in low-voltage status.
LCD will indicate continuously for reminding the
user to recharge the battery. If the battery is still
running in low-voltage status without being recharged,
WEIGHT LCD will indicate
-OFF-
and the scale will
sound
beep
repeatedly. Please power of the scale
and recharge the battery (refer to page 10) as soon
as possible.
-
-