background image

HOBO

®

 U10 Temp/RH Data Logger (Part # U10-003) 

© 2005–2012 Onset Computer Corporation 
Part #: MAN-U10-003, Doc #: 11196-B 

Inside this package: 

 

HOBO U10 Temp/RH  
Logger 

 

Mounting kit with magnet, hook-and-loop 
tape, and 3/8” double-sided tape. 

 

 

Doc # 11196-B, MAN-U10-003 
Onset Computer Corporation 

Thank you for purchasing a HOBO data 
logger. With proper care, it will give you 
years of accurate and reliable measurements. 

The HOBO U10-003 is a two-channel 
Temperature/Relative Humidity Data Logger 
with 10-bit resolution and capacity for 
52,000 measurements. The logger uses a 
direct USB interface for launching and data 
readout by a computer.  

HOBOware

®

 software is required for logger 

operation. Visit www.onsetcomp.com for 
details. 

 

 

Specifications 

Measurement 
range 

Temperature: -20° to 70°C (-4° to 158°F) 
RH: 25% to 95% RH 

Accuracy 

Temperature: ± 0.53°C from 0° to 50°C (± 0.95°F 
from 32° to 122°F), see Plot A 
RH: ± 3.5% from 25% to 85% over the range of 
15° to 45°C (59° to 113°F), see Plot B; ± 5% 
from 25% to 95% over the range of 5° to 55°C 
(41° to 131°F), see Plot B 

Resolution 

Temperature: 0.14°C at 25°C (0.25°F at 77°F), 
see Plot A 
RH: 0.07% @ 25°C and 30% RH 

Drift 

Temperature: 0.1°C/year (0.2°F/year) 
RH: <1% per year typical 

Response time in 
airflow of 1 m/s 
(2.2 mph) 

Temperature: 10 minutes, typical to 90% 
RH: 6 minutes, typical to 90% 

Time accuracy 

Approximately ± 1 minute per month at 25°C 
(77°F), see Plot C 

Operating range 

Logging: -20° to 70°C (-4° to 158°F); 0 to 95% 
RH (non-condensing) 

Battery life 

1 year typical use 

Memory 

64K bytes (52,000 10-bit measurements) 

Weight 

26 g (0.82 oz) 

Dimensions 

45 x 60 x 20 mm (1.8 x 2.38 x 0.77 inches) 

 

The CE Marking identifies this product as 
complying with the relevant directives in the 
European Union (EU). 

 

 

Plot A 

 

 

Plot B 

 

Plot C 

Connecting the logger 

The U-Series logger requires an Onset-supplied USB interface cable to 
connect to the computer. If possible, avoid connecting at temperatures 
below 0°C (32°F)

 

or above 50°C (122°F). 

1.  Plug the large end of the USB interface cable into a USB port on the 

computer.  

2.  Plug the small end of the USB interface cable into the side of the 

logger as shown in the following diagram. 

3.  Load and use logger software to operate the logger (see software 

manual). 

Not Specified 

+/- 5% 

+/-3.5% 

100% 

90% 

80% 

70% 

60% 

50% 

40% 

30% 

20% 

U10 RH Accuracy 

10 

20 

30 

40 

  50 

60 

50 

°C 