background image

 

RXW Temperature Sensor (RXW-TMB-xxx) Manual 

1-800-LOGGERS 

www.onsetcomp.com 

data, then it may be damaged or worn out if it has been in use 

for several years. 

Updating Mote Firmware 

If a new firmware version is available for the mote, use 

HOBOlink to download the file to your computer. 
1.

 

In HOBOlink, go to Devices, then RX Devices, and click your 

station name. 

2.

 

On the station page, click Overview and scroll down to 

Device Information. 

3.

 

Click the Wireless tab. This icon 

 appears next to the 

mote if there is a new version of firmware available. 

4.

 

Click the firmware 

 upgrade link. Click Download and 

save the firmware .bin file to your computer. 

5.

 

Connect the mote to the computer with a USB cable (open 

the mote door and use the USB port to the right of the 

LCD). The blue LED is illuminated while connected. 

6.

 

The mote appears as a new storage device in the 

computer’s file storage manager. Copy the downloaded 

firmware file to the new storage device (the mote). The 

blue LED will blink slowly while the file is copying. 

7.

 

After the file is copied to the mote, the LED will stop 

blinking and remain a steady blue. Eject the storage device 

from the computer and disconnect the cable from the 

mote. The firmware installation process will begin 

automatically on the mote. The blue LED will blink rapidly 

while the firmware is installed. Once the firmware 

installation is complete, the LCD symbols return and the 

mote will automatically rejoin the network. 

Notes: 

 

Mac® users: A message may appear indicating the disk 

has not ejected properly when disconnecting the mote 

from the computer. The mote is operational and you can 

ignore the message. 

 

If the blue LED turns off abruptly while copying the file or 

installing the firmware, a problem has occurred. Contact 

Onset Technical Support for help. 

Battery Information 

The mote uses two 1.2 V rechargeable NiMH batteries, charged 

by the built-in solar panel. The quality and quantity of solar 

light can affect whether the battery is sufficiently charged to 

last through the night and cloudy periods. Make sure the mote 

is placed in a location that will receive several hours of sunlight 

each day. If the mote does not receive enough sunlight to 

recharge the batteries, the battery life is estimated at 3–4 

months. When batteries are regularly recharged, expected 

battery life is estimated at 3–5 years. Battery life varies based 

on the ambient temperature where the mote is deployed, the 

logging interval, the number of tripped alarms, and other 

factors. Deployments in extremely cold or hot temperatures 

can impact battery life. Estimates are not guaranteed due to 

uncertainties in initial battery conditions and operating 

environment. 
Mote operation will stop when battery voltage drops to 1.8 V. 

Mote operation will return if the battery recharges to 2.3 V. If 

the batteries are unable to be recharged, replace them with 

fresh rechargeable batteries. 

Note:

 if you install used 

rechargeable batteries that together are less than 2.3 V, the 

mote will not resume operation. 
To replace rechargeable batteries: 
1.

 

Open the mote door. 

2.

 

Remove the old batteries and install fresh ones observing 

polarity. 

3.

 

Make sure the solar panel cable is plugged in. 

 

The mote contacts the network once the new batteries are 

installed. The green LED blinks during this process while the 

bars in the signal strength indicator on the LCD cycle from left 

to right and then the x icon blinks. Once this process is 

complete, the x icon is removed, the green LED stops blinking, 

and the blue LED begins blinking instead. 

Lithium Batteries 

You can use two 1.5 V lithium batteries (HWSB-LI) for operation 

at the extreme ends of the mote operating range. Lithium 

battery life is an estimated at 1 year, but varies based on the 

ambient temperature where the mote is deployed, the logging 

interval, the number of tripped alarms, and other factors. 

Estimates are not guaranteed due to uncertainties in initial 

battery conditions and operating environment. When using 

lithium batteries, you must disconnect the solar panel cable 

because the batteries will not be recharged. 
To install lithium batteries: 
1.

 

Open the mote door. 

2.

 

Remove any old batteries and install the new ones 

observing polarity. 

3.

 

Push in the side tab of the solar panel cable connector and 

pull the connector out of the cable port. 

4.

 

Place the connector in the slot on the inside of the mote 

door. Make sure the solar panel cables are tucked inside the 

door so that they do not interfere with the interior seal 

when the mote is closed. 

 

Store the solar 

panel connector 

here when using 

lithium batteries 

Make sure 

solar panel 

cable is 

installed 

when using 

rechargeable 

batteries 

Reviews: