TM-260 273 Page 23
Handler 190
228 180-A
Voltage Readings
a)
Tolerance −
±
10 % unless
specified
b)
Wiring Diagram − see Section 8
V1
230 volts ac with power cord plugged in
V2
230 volts ac with Power switch S1 On
V3
24 volts ac with Power switch S1 On
V4
28 volts dc with Power switch S1 On
V5
24 volts ac with gun trigger closed
V6
12.9 volts ac with Voltage switch S2
in position 1 and gun trigger closed
14.4 volts ac with Voltage switch S2
in position 2 and gun trigger closed
15.9 volts ac with Voltage switch S2
in position 3 and gun trigger closed
17.5 volts ac with Voltage switch S2
in position 4 and gun trigger closed
19.0 volts ac with Voltage switch S2
in position 5 and gun trigger closed
20.5 volts ac with Voltage switch S2
in position 6 and gun trigger closed
22.1 volts ac with Voltage switch S2
in position 7 and gun trigger closed
V7
12.9 volts ac with Voltage switch S2
in position 1 and gun trigger closed
14.4 volts ac with Voltage switch S2
in position 2 and gun trigger closed
15.9 volts ac with Voltage switch S2
in position 3 and gun trigger closed
17.5 volts ac with Voltage switch S2
in position 4 and gun trigger closed
19.0 volts ac with Voltage switch S2
in position 5 and gun trigger closed
20.5 volts ac with Voltage switch S2
in position 6 and gun trigger closed
22.1 volts ac with Voltage switch S2
in position 7 and gun trigger closed
V8
17.6 volts dc with Voltage switch S2
in position 1 and gun trigger closed
19.7 volts dc with Voltage switch S2
in position 2 and gun trigger closed
21.8 volts dc with Voltage switch S2
in position 3 and gun trigger closed
23.9 volts dc with Voltage switch S2
in position 4 and gun trigger closed
26.0 volts dc with Voltage switch S2
in position 5 and gun trigger closed
28.1 volts dc with Voltage switch S2
in position 6 and gun trigger closed
30.3 volts dc with Voltage switch S2
in position 7 and gun trigger closed
Voltage Readings (Continued)
V9
230 volts ac with gun trigger closed
V10
1.8 to 15.0 volts dc from min. to max.
of Wire Speed control R2 with
Voltage switch S2 in position 1
2.2 to 17.0 volts dc from min. to max.
of Wire Speed control R2 with
Voltage switch S2 in position 2
2.7 to 19.2 volts dc from min. to max.
of Wire Speed control R2 with
Voltage switch S2 in position 3
3.2 to 21.3 volts dc from min. to max.
of Wire Speed control R2 with
Voltage switch S2 in position 4
3.7 to 23.4 volts dc from min. to max.
of Wire Speed control R2 with
Voltage switch S2 in position 5
4.2 to 24.2 volts dc from min. to max.
of Wire Speed control R2 with
Voltage switch S2 in position 6
4.8 to 24.6 volts dc from min. to max.
of Wire Speed control R2 with
Voltage switch S2 in position 7
Resistance Values
a)
Tolerance −
±
10% unless specified
b)
Turn Off unit and disconnect input
power before checking resistance
R1-R10
All values for T1 are less than 1 ohm
R11
Less than 1 ohm with gun trigger pressed,
high resistance with gun trigger open
R12
Less than 1 ohm
R13
Less than 1 ohms at minimum position of
Wire Speed control R2, 50k ohms at
maximum position of R2