9
5
First run
5.1
Rinse agent
–
Put the suction hose (
blue
) into the rinse agent storage
container.
5.2
Detergent
(only on option)
Do not use any acid detergent products with the built-in
detergent pump! (The ph-value has to be higher than 7.)
–
Put the suction hose (
white
) into the detergent storage container.
The sucking high of dosing pumps is max. 1.5 meters.
Do not confuse the containers !
Use only commercial detergent and rinse agent.
Please pay attention to the manufacturers safety rules
and instructions!
5.3
Softener
(only on option)
The machine will be delivered without salt. For the first run,
the softener has to be filled with salt and water.
–
Open hood.
–
Unscrew the softener lid and fill the softener with
2
kg of
"Granular salt" (do not use salt tablets).
–
Fill up the softener with drinking water.
Clean seal and rim of softener lid carefully, before closing
the lid.
–
Close lid and tighten.
5.4
Filling of the rinse booster heater and pre-dosing
–
Close hood.
– Open shut-off valve.
– Switch on main switch or put the plug in.
–
Push the
ON/OFF
button
➀
,
the button illuminates. At the
temperature indicator
Rinse
➅
appears "
boF
" and flashes.
The rinse booster heater has to be filled as described in the
following text.
–
Push the
ON/OFF
button
➀
again, to switch off the machine.
–
Open hood, push
Program
button
➃
and
Drain
button
➂
simultaneously until at the temperature indicator
Rinse
➅
appears again "
boF
".
–
Push
Start
button
➁
. At the temperature indicator
Wash
➄
appears "
- - 1
". Wait until the indicator displays "
- - 0
".
–
Close hood. The machine switches off and is now ready for
operation.