5
2.2
Water connection
Must be carried out by an authorized technician
according to the national and local codes.
The machine must be operated with water of drinking quality.
For water with an extremely high mineral content, water
treatment is recommended.
Machines without softener
–
Connect to soft and if possible warm water
(up to 4° Clark = 0.5 mmol/l,
max. 60°C
).
–
Line flow pressure 0.5 – 10 bar.
Important:
the line flow pressure must not be less than 0.5 bar.
– If the line flow pressure is above 10 bars: provide pressure
reducer at source.
Machines with softener
–
Connect to warm water (
max. 60°C
) if possible.
–
Line flow pressure 0.5 – 10 bar.
Important:
the line flow pressure must not be less than 0.5 bar.
– If the line flow pressure is above 10 bar: provide pressure
reducer at source.
–
Connect the union nut "
A
" (
3
/
4
") of the water supply hose
with the site shut off valve.
–
Do
not kink
or
cut
the supply hose.
2.3
Drain connection
–
Connection between machine and site drain must not exceed
max. height of 800 mm.
–
Do not kink the drain hose.
3
Connecting of detergent pump
If no detergent pump was ordered, please connect the detergent
dispenser as described below.
Must be carried out by an authorized technician
according to the local and national codes.
–
Tank must be drained.
– Switch off main switch or unplug.
– Liquid detergent dispenser:
remove front panel.
Powder or solid detergent dispenser:
remove front panel
and the left hand or right hand side panel (according to
requirement on site).
A
max. 800 mm
30
°
-45
°