HMS EC71330 00MA Installation Manual Download Page 18

Troubleshooting

16 (24)

6

Troubleshooting

6.1

Normal Boot Process

The normal boot process of the Ewon Cosy+ takes approximately 1m30 to 2 minutes to complete.
During this process, all LEDs are first shortly on (except BI1) then only the

PWR

LED stays steady

green.

As soon as the boot process is completed and the unit is ready to be used, the

USR

LED blinks

green slowly whereas others might be steady green (if the device is connected to Internet,
Talk2M...).

6.2

Resetting the Ewon Cosy+

The reset button

BI1

is located on the front of the Cosy+ (see

Front, p. 12

). The reset function of

this button is active only if pressed while powering on.

The Ewon Cosy+ features two levels of reset:

6.2.1

First Reset Level: User Reset

The first reset level is a selective reset that erases the user files part and the system settings. This
type of reset does not alter the communication parameters of the Ewon Cosy+.

Hereunder is the process to perform a first reset level:

Power off the unit.

While powering it on, press & maintain the reset button. The LED labeled

BI1

turns green.

Keep the reset button pressed for approximately 30 seconds until the

USR

LED blinks red 1x

per second. If it isn’t released at that specific moment, a second level reset phase is initiated.
The LED labeled

BI1

turns off.

Wait approximately 30 seconds until the reset process is completed.

The Cosy+ automatically restarts and the unit is ready to be used, the

USR

LED blinks green

slowly (this entire step takes approximately 2 minutes).

6.2.2

Second Reset Level: Factory Reset

The second level reset restores the Cosy+ to its factory settings. This operation consists in 3
steps:

Format the entire non volatile memory, including all COM parameters and IP addresses

Full hardware auto-test with result shown by the

USR

LED

Return to ex-factory configuration (default configuration)

Hereunder is the process to perform a second reset level:

Power off the unit.

While powering it on, press & maintain the reset button. The LED labeled

BI1

turns green.

Keep the reset button pressed for approximately 35 seconds until the

USR

LED remains red

steady.

When this state is reached, release the button. The LED labeled

BI1

turns off.

Check if the auto test is successful, the

USR

LED blinks red with a pattern of 200ms on and

800ms off. The Cosy+ does NOT restart by itself in normal mode and remains running in this
diagnostic mode.

Ewon Cosy+ Installation Guide

IG-0031-00 1.0 en-US

Summary of Contents for EC71330 00MA

Page 1: ...Ewon Cosy INSTALLATION GUIDE IG 0031 00 1 0 en US ENGLISH...

Page 2: ...ible applications of the product and because of the many variables and requirements associated with any particular implementation HMS Networks cannot assume responsibility or liability for actual use...

Page 3: ...wer Supply 5 3 3 Applicable Directives Standards and Compliance 5 3 4 Field Implementation Environmental Conditions 5 3 5 Internal Battery 9 4 Hardware Description 11 4 1 Label 11 4 2 Overall Descript...

Page 4: ...Ewon Cosy Installation Guide IG 0031 00 1 0 en US B Specification of the External Power Supply 20 C Digital Output Digital Inputs 21 C 1 Possible Features 22...

Page 5: ...won biz support 1 2 Document History Version Date Description 1 0 2020 01 08 First release 1 3 Related Documents Document Author Document ID eBuddy HMS AUG 0063 00 Connect an Ewon device to Talk2M HMS...

Page 6: ...bps Digital Input 2 Digital Output 1 Mounting Latch for DIN rail EN50022 compliant 2 3 Typical Applications The Ewon Cosy can be used for remote access of Ethernet and or USB devices using Talk2M conn...

Page 7: ...Restriction This equipment is not suitable for use in locations where children are likely to be present 3 4 2 Ingress Protection The Ewon Cosy has an IP20 protection grade Therefore the Ewon Cosy is N...

Page 8: ...DIN rail mounting position Description 1 SIM card slot 2 DIN rail mounting bracket Fig 2 Wall mounting position Description 1 SIM card slot 2 Wall mounting bracket suggested screw dimensions 4 2 x 32...

Page 9: ...a free gap of at least 2 cm must be respected in front of all upper lower ventilation openings of the unit A free gap of at least 1 cm must be respected on each side of the unit Fig 3 Free gap surroun...

Page 10: ...Safety Environmental Regulatory Information 8 24 Ewon Cosy Installation Guide IG 0031 00 1 0 en US...

Page 11: ...torage Humidity 10 to 95 non condensing Storage Altitude Up to maximum 3000m In any other mounting position than the one explained above the specified operating temperature has to be derated to 25 C t...

Page 12: ...use several internal burns in just 2 hours and can lead to death If the equipment s enclosure do not close securely stop using the product and keep it away from children If you think batteries might h...

Page 13: ...ments Marks CE UL logos if applicable The applicable marks on the Ewon Cosy are the following Marks Description Conformit Europ enne or European Conformity EC UL Listed Underwriters Laboraties FCC Fed...

Page 14: ...XXXXX Label Description Cosy The device is labeled as Ewon Cosy Model XXXXX A unique hardware identifier of the product for certification purposes 4 2 Overall Description 4 2 1 Front Fig 6 Front pane...

Page 15: ...tch Specifications 4 3 1 Boot Process After powering on or requesting a reboot of the Ewon Cosy a wait is required to get the LAN switch feature fully operational approximately 2 to 4sec The Cosy shou...

Page 16: ...Ewon Cosy companion tool eBuddy which can be downloaded from www ewon biz support Connect a LAN port port 1 is always set as a LAN port of the Ewon Cosy to one s computer either through a point to po...

Page 17: ...an Ewon device to Talk2M from Related Documents p 3 The Embedded Wizard Setup If your Ewon Cosy hasn t been configured yet a configuration wizard will be proposed which sets the basics settings of th...

Page 18: ...seconds until the USR LED blinks red 1x per second If it isn t released at that specific moment a second level reset phase is initiated The LED labeled BI1 turns off Wait approximately 30 seconds unti...

Page 19: ...error pattern occurs on the USR LED please check out the troubleshooting page www ewon biz support 6 3 Impact Matrix of a Reset Reset level Erased or Reset Preserved Impact of a reset level 1 User res...

Page 20: ...This page intentionally left blank...

Page 21: ...e absence of a torque wrench a soft manual tightening is sufficient Fig 9 Connector pinout PIN ICON ID Description 1 O DO_COM Output signal 0V ground connected to the emitter of the MOSFET transistor...

Page 22: ...should be separately certified according to UL IEC 62368 1 with ES1 PS2 output or separately certified to IEC UL60950 1 with LPS output or Class2 per NEC Characteristics of the power supply can be fo...

Page 23: ...ocoupler The maximum current flow inside this transistor has a value above the one specified in the Cosy in order to cope with the switching power losses The transistor used is in an open drain type w...

Page 24: ...tive remote connection remote user connected Here is a summary of the DO status based on Talk2M connectivity T2M LED off DO off There is no VPN tunnel established T2M LED steady DO off The VPN tunnel...

Page 25: ...This page intentionally left blank...

Page 26: ...last page 2021 HMS Industrial Networks Box 4126 300 04 Halmstad Sweden info hms se IG 0031 00 1 0 en US 2021 04 30 22283...