4 (44)
2
Safety
2.1
General Safety Instructions
Caution
This equipment emits RF energy in the ISM (Industrial, Scientific, Medical) band. Make
sure that all medical devices used in proximity to this device meet appropriate
susceptibility specifications for this type of RF energy.
This product is recommended for use in both industrial and domestic environments. For
industrial environments it is mandatory to use the functional earth connection to comply
with immunity requirements. For domestic environments the functional earth must be
used if a shielded Ethernet cable is used, in order to meet emission requirements.
This product contains parts that can be damaged by electrostatic discharge (ESD). Use
ESD prevention measures to avoid damage.
2.2
External Antenna Restrictions
For models with external antenna, only use antennas that are certified for use with this
equipment. Using external antennas that are not certified for use with this equipment will
invalidate its certifications and make it non-compliant with the regulations for radio equipment.
A list of certified antennas can be found at
.
2.3
Intended Use
The intended use of this equipment is as a communication interface and gateway. The
equipment receives and transmits data on various physical levels and connection types.
If this equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
2.4
Type Identification
The type name consists of a type prefix followed by two designators for interface configuration
and functionality.
Prefix
AWB3
Anybus Wireless Bridge II
Interface configuration
A
B
Internal antenna, Dual M12
External antenna, Dual M12, RP-SMA
Functionality
A
B
Ethernet with digital input
Ethernet w/o digital input
Example:
AWB3AA = Anybus Wireless Bridge II with internal antenna, Ethernet networking and
digital input.
Anybus
®
Wireless Bridge II
™
User Manual