12 (24)
4.7
Connecting Power Wires
Caution
Ensure that the power supply is turned off before connecting it to the
switch.
Use a power supply of 8–32 VDC to power the switch.
Max power consumption: 4.8 W.
The relay contact supports 0.5 A current, 24 VDC.
Procedure
1.
Connecting to main power supply P1:
Insert the positive and negative
wires into the
P1+
and
P1-
contact on the
8 pin terminal block
.
2.
Connecting to redundant power supply P2:
Insert the positive and
negative wires into the
P2+
and
P2-
contact on the
8 pin terminal block
.
3.
Tighten the
wire-clamp screws
.
4.
Connect the power wires to a
DC switching type power supply
.
Anybus
®
Managed Industrial L3 Switch Startup Guide
SP2556 1.1 en-US