HMS Anybus AWB4004 Startup Manual Download Page 2

Important User Information

Disclaimer

The information in this document is for informational purposes only. Please inform HMS Industrial
Networks of any inaccuracies or omissions found in this document. HMS Industrial Networks disclaims
any responsibility or liability for any errors that may appear in this document.

HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous
product development. The information in this document shall therefore not be construed as a
commitment on the part of HMS Industrial Networks and is subject to change without notice. HMS
Industrial Networks makes no commitment to update or keep current the information in this document.

The data, examples and illustrations found in this document are included for illustrative purposes and are
only intended to help improve understanding of the functionality and handling of the product. In view of
the wide range of possible applications of the product, and because of the many variables and
requirements associated with any particular implementation, HMS Industrial Networks cannot assume
responsibility or liability for actual use based on the data, examples or illustrations included in this
document nor for any damages incurred during installation of the product. Those responsible for the use
of the product must acquire sufficient knowledge in order to ensure that the product is used correctly in
their specific application and that the application meets all performance and safety requirements
including any applicable laws, regulations, codes and standards. Further, HMS Industrial Networks will
under no circumstances assume liability or responsibility for any problems that may arise as a result from
the use of undocumented features or functional side effects found outside the documented scope of the
product. The effects caused by any direct or indirect use of such aspects of the product are undefined
and may include e.g. compatibility issues and stability issues.

Anybus

®

WLAN Access Point IP67 Startup Guide

SP2383 1.3 en-US

Summary of Contents for Anybus AWB4004

Page 1: ...Anybus WLAN Access Point IP67 STARTUP GUIDE SP2383 1 3 en US ENGLISH...

Page 2: ...nge of possible applications of the product and because of the many variables and requirements associated with any particular implementation HMS Industrial Networks cannot assume responsibility or lia...

Page 3: ...s 4 2 2 Intended Use 4 2 3 5 GHz Transmission Power Restriction EU only 5 3 Installation 6 3 1 Overview 7 3 2 Wall Mounting 8 3 3 Pole Mounting 9 3 4 Power Connector M12 10 3 5 Ethernet Connector M12...

Page 4: ...This page intentionally left blank...

Page 5: ...to indicate safety information and other important content in this document WARNING Instruction that must be followed to avoid a risk of death or serious injury Caution Instruction that must be follow...

Page 6: ...e ESD Use ESD prevention measures to avoid damage To prevent water intrusion make sure that the unit is installed with the connectors on the bottom panel of the unit facing down 2 2 Intended Use The i...

Page 7: ...dio Equipment Directive RED the effective radiated power output for 5 GHz channels 149 165 U NII 3 must not exceed 25 mW 14 dBm when the unit is used in the EU To configure the unit for use within the...

Page 8: ...observed to avoid interference Make sure that you have all the necessary information about the capabilities and restrictions of your local network environment before installation Package Contents Afte...

Page 9: ...erview Fig 2 Overview 1 2 Antenna connector N 3 8 Threaded hole for grounding screw 4 Ethernet connector M12 5 Reset button 6 LED indicators 7 Power connector M12 Anybus WLAN Access Point IP67 Startup...

Page 10: ...plate to the back of the unit using the 4 included screws The plate can be attached vertically or horizontally 2 Hold the unit upright against the wall and fasten it with 4 screws through the apertur...

Page 11: ...ached vertically or horizontally 2 Thread the two supplied metal mounting straps through the large slots on the mounting plate and then put the straps around the pole To prevent water intrusion make s...

Page 12: ...reverse polarity or using the wrong type of power supply may damage the equipment Make sure that the power supply is correctly connected and of the recommended type See also Technical Data p 15 regar...

Page 13: ...with the equipment The power source must be UL UL 62368 1 certified for UL compliance fully compliant with IEEE 802 3af marked Limited Power Source LPS or Class 2 and have a rated voltage of 48 VDC a...

Page 14: ...enters the building Power cable and Ethernet cable are not included with the unit The cables and connectors must be waterproof and installed by a professional 3 7 Grounding When connecting a ground w...

Page 15: ...Power Input 1 PWR2 Green Power supplied on Power Input 2 PoE Green Power supplied on Ethernet port ETH Off No LAN Green LAN link established Green flashing LAN traffic WLAN Off No WLAN Green WLAN lin...

Page 16: ...access point Default web interface settings IP address 192 168 0 2 User ID admin Password admin See the Anybus WLAN Access Point IP67 User Manual for more information about how to configure the acces...

Page 17: ...orage temperature 40 to 85 C Humidity 5 to 95 non condensing Mounting Wall mount or pole mount Housing Metal Protection class IP67 Certifications See datasheet For more technical details and specifica...

Page 18: ...Technical Data 16 18 5 2 Dimensions Fig 7 Dimensions All measurements are in mm Anybus WLAN Access Point IP67 Startup Guide SP2383 1 3 en US...

Page 19: ...This page intentionally left blank...

Page 20: ...last page 2019 HMS Industrial Networks Box 4126 300 04 Halmstad Sweden info hms se SP2383 1 3 en US 2019 08 26 14475...

Reviews: