In operation, you can change the running speed of the c
urrent time period by pressing the “Speed” + “” or
“Speed”
-
“” keys. Press the "Stop" button to stop the movement.
7. Heart rate test: After the stair machine is powered on, hold the hand on the heartbeat metal sensor
piece, and the heart rate display window will display the user's heart rate value after a few seconds.
(Note: This value is not used as medical data and can only be used as a sports reference.)
Note: During the movement, the safety key is pulled off, the stairs will stop running immediately, the
electronic watch will refuse any operation, and the window will display “
----
” or E07 error code!
Product maintenance and maintenance
1.
Lubrication
After the machine is used for a period of time, there may be grease oxidation and accumulation of
stains on the chain and the sprocket. It is recommended to clean it regularly and change the oil!
Note: Regular cleaning of belt and pulley groove cleaning
Maintenance
Proper maintenance is very important to ensure a faultless and operational condition of the
treadmill. Improper maintenance can cause damage to the treadmill or shorten the life of the
product.
All parts of the treadmill must be checked and tightened regularly. Worn out parts must be replaced
immediately.
Technical data
Assembly size: 146,4 x 81 x 255,5 cm
Max User’s weight: 160 kgs
N.W.: 175 kgs
G.W.: 205 kgs
Stair machine part
Problem
Reason
Solution
The stair machine doesn't work
1. No plugged in
1. Plug into the socket
2. Safety key is not embedded
2. Embed the safety key in the
panel
3. Circuit signal system open
circuit
3. Check controller inputs and
signal lines
4. Power is not turned on
4. Set the power switch to the ON
position
Running belt does not work
smoothly
1. Insufficient lubrication
1. Clean up the chain stains and re-
grease the grease
2. Chain too tight
2. Adjust the chain tightness