7.

 

Error Codes 

 

Error Code 

Description 

No active error 

1102 

Discharge Temperature high 

1108 

Internal thermostat detector working (49C) 

1110 

Outdoor unit fail 

1300 

Pressure low 

1302 

Pressure high (High pressure probe working 63H) 

1503 

Protection against freeze or battery high temperature 

1504 

Protection against freeze or battery high temperature 

1504 

Overheating protection 

1509 

High pressure error (ball valve closed) 

1520 

Super heating anomaly due to low temp. of discharge. (TH4) 

2500 

Erroneous operation of drain pump 

2502 

Erroneous operation of drain pump 

2503 

Drain sensor anomaly (DS) 

4030 

Serial transmission error 

4100 

Compressor pause due to excess of current (initial block) 

4101 

Compressor pause due to excess of current (overload) 

4102 

Phase detection opened  

4103 

Anti-phase detection 

4108 

Phase opened in phase L2 or connector 51CM opened 

4118 

Error in the anti-phase detector (electronic board) 

4124 

Connector 49L opened 

4210 

Cut due to over-current of compressor 

4220 

Voltage anomaly 

4230 

Radiator panel temperature anomaly (TH8) 

5101 

Ambient temperature probe anomaly (TH1), indoor unit 

5102 

Liquid probe anomaly (TH2) 

5102 

Cond/Evap probe anomaly (TH5) 

5104 

Error detection in discharge temperature 

5105 

Outdoor probe error TH3 

5106 

Outdoor probe errorTH7 

5107 

Outdoor probe errorTH6 

5110 

Outdoor probe errorTH8 

5202 

Connector 63L opened 

5300 

Current probe error 

6600 

MNET duplicated address definition 

6602 

MNET Line transmission hardware error 

6603 

MNET BUS busy 

6606 

MNET Line transmission error 

6607 

MNET transmission error 

6607 

MNET without ack 

6608 

MNET transmission error 

6608 

MNET without response 

6831 

AC’s

 remote command transmission error (reception error) 

6832 

AC’s remote command transmission error 

(transmission error) 

6840 

Transmission error with the indoor/outdoor unit (reception error) 

6841 

Transmission error with the indoor/outdoor unit (transmission error) 

6844 

Error  in  inter-connection  cable  in  the  indoor/outdoor  unit,  indoor  unit 
number deactivated (5 min or more) 

6845 

Error  in  inter-connection  cable  in  the  indoor/outdoor  unit  (cabling 
error, disconnection) 

6846 

Initial timer deactivated 

65535  

(-1) 

Error in the communication of INMBSMIT001I000 with the AC Unit 

 

In  case  to  detect  an  error  code  not  listed,  contact  your  closest  Mitsubishi  Electric  technical 
support service.

 

Summary of Contents for Intesis EIA-485

Page 1: ...Compatible with Domestic Mr Slim and City Multi lines commercialized by Mitsubishi Electric USER MANUAL Issue date 12 2017 r22 ENGLISH...

Page 2: ...s information is subject to change without notice URL https www intesis com 2 20 Modbus RTU EIA 485 Interface for Mitsubishi Electric air conditioners Compatible with Domestic Mr Slim and City Multi l...

Page 3: ...d are only intended to help improve understanding of the functionality and handling of the product In view of the wide range of possible applications of the product and because of the many variables a...

Page 4: ...Quick Start Guide 7 4 Modbus Interface Specification 8 4 1 Modbus physical layer 8 4 2 Modbus Registers 8 4 2 1 Control and status registers 8 4 2 2 Configuration Registers 10 4 2 3 Considerations on...

Page 5: ...required Direct connection to Modbus RTU EIA 485 networks Up to 63 INMBSMIT001I000 devices can be connected on the same network INMBSMIT001I000 is a Modbus slave device Direct connection to the AC in...

Page 6: ...nic circuit You can place the INMBSMIT001I000 inside or outside the AC indoor unit depending on your needs Remember that the INMBSMIT001I000 must also be connected to the Modbus RTU EIA 485 network Cl...

Page 7: ...e and the AC indoor unit following the instructions of the diagram 4 Connect the EIA 485 bus to the interface s EIA485 connector 5 Close the AC indoor unit 6 Check the DIP Switch configuration of the...

Page 8: ...ion 4 2 1 Control and status registers Register Address protocol address Register Address PLC address R W Description 0 1 R W AC unit On Off 0 Off 1 On 1 2 R W AC unit Mode 1 0 Auto 1 Heat 2 Dry 3 Fan...

Page 9: ...other error present see the table at the end of this document 22 23 R W Indoor unit s ambient temperature from external sensor at Modbus side 1 2 3 6 32768 Initialization value No temperature is being...

Page 10: ...ption 12 13 R W AC Model 13 14 R W Open Window switch off timeout 9 0 30 minutes Factory setting 30 minutes 14 15 R Modbus RTU baud rate 2400bps 4800bps 9600bps Default 19200bps 38400bps 57600bps 7680...

Page 11: ...rovide directly a temperature to be used as a reference of the control loop of the AC indoor unit In order to overcome this limitation and enable the usage of an external temperature sensor e g from M...

Page 12: ...tpoint s value shown by the Remote Controller or other Control System from Mitsubishi connected to the indoor unit may show a different value from the value shown in register 4 5 The User is not be ab...

Page 13: ...rks S L U All rights reserved This information is subject to change without notice URL https www intesis com 13 20 Fahrenheit value Value in Modbus register is the temperature value in Fahrenheit i e...

Page 14: ...e following locations The following tables apply to the interface s configuration through DIP switches SW1 AC indoor unit s features SW1 P1 4 Description Not used Default value Not used Not used Defau...

Page 15: ...EIA 485 termination resistor Table 4 3 SW4 Temperature and termination resistor configuration SW4 P1 2 4 Description Temperature values in Modbus register are represented in degrees x1 Default value...

Page 16: ...s Add SW3 P1 6 Add SW3 P1 6 Add SW3 P1 6 Add SW3 P1 6 Add SW3 P1 6 0 13 26 39 52 1 14 27 40 53 2 15 28 41 54 3 16 29 42 55 4 17 30 43 56 5 18 31 44 57 6 19 32 45 58 7 20 33 46 59 8 21 34 47 60 9 22 35...

Page 17: ...s ON 2s OFF Device correctly configured and working During normal operation LED OFF OFF continuously No Modbus Slave address configured During normal operation LED blinking 200ms ON 200ms OFF Communic...

Page 18: ...tage signals For terminal solid wires or stranded wires twisted or with ferrule 1 core 0 5mm2 2 5mm2 2 cores 0 5mm2 1 5mm2 3 cores not permitted Stock Humidity 95 RH non condensing Modbus RTU port 1 x...

Page 19: ...subject to change without notice URL https www intesis com 19 20 6 List of supported AC Unit Types A list of Mitsubishi Electric indoor unit model s references compatible with INMBSMIT001I000 and its...

Page 20: ...t of compressor 4220 Voltage anomaly 4230 Radiator panel temperature anomaly TH8 5101 Ambient temperature probe anomaly TH1 indoor unit 5102 Liquid probe anomaly TH2 5102 Cond Evap probe anomaly TH5 5...