A. CHANGING THE FILTER CONES
For best performance, replace Cones as recommended by manufacturer:
t
BioCone
™
Filter - every month
t
MEDIpure
®
- every 6 months
t
Flat Disc Filter - every 6 months
CAUTION - DO NOT operate your power unit without Filter Cones in place.
BEWARE OF IMITATIONS: Use only Genuine Health-Mor/FILTERQUEEN Filter
Cones. Imitations can result in poor performance and cause damage to your unit.
1. Unplug power cord from wall and detach hose from power unit.
2. Release side clamps and remove power unit from dirt container.
3. Remove MEDIpure
®
Cone and set aside or discard if installing new Cone.
4. Empty contents of dirt container into a large, open garbage bag. Allow contents of
container to fall including used BioCone
™
Filter. Dirt container may be
washed and thoroughly dried to remove all dust and/or any odors.
5. Open a new BioCone
™
Filter. Insert point of Cone into Filter Cone locator
in the bottom of the dirt container. Be sure all edges of the Cone are even with the
gasket of the dirt container.
6. Place the MEDIPure
®
Cone inside the BioCone
™
Filter.
7. Replace power unit and lock side clamps in place. Be sure all three tabs of the
BioCone
™
Filter are visible outside the power unit.
B. CHANGING THE FLAT DISC FILTER
1. Unplug power cord from wall and detach hose power unit.
2. Release side clamps and remove power unit from dirt container.
3. Remove the Cone guard. Next, remove the Flat Disc Filter by pulling back the plastic
retainer ring with your finger and lifting it out.
4. Replace Flat Disc Filter. Place the filter over the center section of the screen.
Replace the retainer ring by squeezing ring. Make sure ring fits snugly under the
three tabs of the plastic screen. Replace the Cone guard. Be sure the outer edge of the
Cone is seated on the rubber lip around the circumference of the power unit and
replace screw.
B.
B.
10
ENG
LISH
A.
A.