HME COMMUNICATOR COM6000 Instructions Download Page 2

 

Press and hold the B button on the Communicator while pressing and releasing the PWR 
(power) button to turn the unit on, then release the B button.  This will cause the 
Communicator to enter the registration mode.  

  The two power lights next to the A1 and A2 buttons on the Communicator will begin 

blinking red, then will blink green two or three times and go off momentarily.  

  

Wait!

   There may be a short delay. 

  One of the following will happen.  

 

If Registration is Successfully Completed: 

If Registration Failed: 

  A voice message in the headset will say  

“Power on, Beltpac #, Version #, Begin registration, 

Registration complete

, …” 

  After a delay of up to 15 seconds (in some cases), 

the Communicator ID display will show the ID 
number assigned to this Communicator, 
momentarily, and the green status light in the base 
station will be on steady.  You will then hear “

Lane 

# ready

” in the headset.  

NOTE:

  ID numbers are 

assigned sequentially as 0 thru 9, A, b, C, d and E. 

  One of the power lights on the Communicator, 

next to the A1 or A2 button, will remain on steady 
green, indicating the active channel/lane. 

  A voice message in the headset will say 

“Power on, Beltpac #, Version #, Begin 
registration, …”  Both power lights on the 
Communicator will be blinking red, and there may 
be a delay of up to 1.5 minutes before you hear 

Registration failed

.”  

  Note the condition of the Status light in the 

base station. 

  Press the Reset button.  The Status light may 

blink off and on, and change colors.  

  When the Status light returns to the state 

previously noted, press the Registration button 
and repeat the registration procedure.  

  If  registration fails again, call (in the USA) 

HME Customer Support at 

1-800-848-4468

 or 

(outside the USA) your local HME representative 
for assistance. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

When replacing a previously registered COMMUNICATOR

®

If a Communicator is replaced, the new one must be registered.  When a Communicator is 
replaced, the old one remains in memory.  If the maximum number of 15 (in memory) is 
exceeded, all current registrations must be cleared and all active Communicators must be  
re-registered.  To clear all current registrations, press the “Clear All Registration” button and the 
“Reset” button simultaneously.  Refer to Figure 1.  Continue holding the “Clear All Registration” 
button after releasing the “Reset” button, until the clear code “c” (lower case) appears 

momentarily on the Communicator ID display and the Status light is blinking red.  All active 
Communicators can then be registered, one at a time. 

Channel “A1” 

button 

Channel “B” 

button 

Channel “A2” 

button 

Power 
button 

Figure 2.    Registration controls on Communicator 

Reviews: