background image

19

E. Service

Regularly check the vents to ensure air flows freely 
in and out. Clean the foam rubber filters whenever 
necessary. Remove the vent grille on the back to do 
this.

2.  ConTour Array™   

Spare Parts

Note: 
•  If your equipment needs service, please turn 

to your HK AUDIO dealer or the HK AUDIO 
distributor in your country. They stock the 
required spare parts.

•  In the event of a defect, always indicate the 

defective device’s serial number. This way the    
HK AUDIO service team can immediately find out 
if an update is available for your product. 

•  Use only original HK AUDIO replacement speakers 

and parts! Most were developed especially for HK 
AUDIO products and are not available direct from 
speaker manufacturers!

3.  Replacing Loudspeakers 

and Voice Coils

3.1 1", 8" and 18" Speakers 

Proceed as follows to replace the given speaker:
•  Unfasten and remove the Phillips screws holding 

the grille in place. Remove the grille. These screws 
are on the CT 118 Sub’s front panel and the       
CTA 208’s side and bottom panels.

•  Unfasten and remove the hex head bolts holding 

the speaker in place.

•  The speaker is now detached. Disconnect the 

speaker wires.

Caution: When installing and connecting a 
replacement speaker, ensure the polarity is correct!
Red= positive, black = negative 

1. Maintenance

3.2 The Drivers’ Voice Coils

Proceed as follows to replace the drivers’ voice coils:
•  Remove the front grille as described above.
•  Unfasten the four screws holding the horn yoke 

and remove the horn and driver from the baffle.
Disconnect the wires connecting the driver. Ensure 
correct polarity when installing and connecting 
a replacement speaker! Red= positive, black = 
negative

•  Unfasten the voice coil housing’s hex head bolts 

using a 3 mm wrench.

•  Take the lid off the voice coil housing.
•  Replace the voice coil.

Important note: Replace the voice coil in a clean 
working environment only. Be sure to keep dust 
and dirt out of the open driver. If despite your 
precautions particles manage to get in, use a strip 
of adhesive tape to remove them or carefully blow 
compressed air into the back of the driver to whisk 
the particles out. When installing the new voice 
coil, ensure it is centered properly. Proceed as 
follows to check this:
Close the cover of the voice coil housing and 
reconnect the cords (red = positive, black = 
negative). Feed a sine wave signal with a frequency 
between 1000 Hz and 1500 Hz into the mid/high 
enclosure’s input. Sweep through the frequency. 
If you hear abrasive noises like crackling or 
scratching, the voice coil is not centered properly. 
Reopen the voice coil chassis and turn the voice coil 
a bit until it renders the signal cleanly!

4. Checking Speakers’ Phase

As a precaution, always check the components’ 
phase using a suitable phase-checker after replacing 
speakers. To do this, connect the CTA 208 mid/high 
unit to the CTA 118 Sub using a Speakon

®

 cord. 

Note: If you are checking the CTA 208 mid/high 
unit in passive mode with an external power amp, 
you will get a different phase reading! Therefore 
always use the CTA 118 Sub for phase checks.

Connect the phase-checker to the CTA 118’s signal 
input. It may be advisable to lower the input level on 
the DDO-Pro™ Controller!
The speakers’ phases should read as follows:

With CTA 118 Sub:
18" woofer: 

In phase (+)

8" speaker: 

Out of phase (-)

1" driver: 

In phase (+)

CTA 208 passive:
8" speaker: 

In phase (+)

1" driver: 

Out of phase (-)

En

g

li

sh

Summary of Contents for CONTOUR ARRAY

Page 1: ...1 Manual 1 4 ConTour Array English Deutsch Français ...

Page 2: ...al other power consumers The plug socket for the power supply must be positioned near the unit and must be easily accessible PLACE OF INSTALLATION The unit should stand only on a clean horizontal working surface The unit must not be exposed to vibrations during operation Place the product always in a way that the mains switch is easily accessible Keep away from moisture and dust where possible Do ...

Page 3: ...r 15 1 The DDO Pro Net Port 15 2 Audio Signal Routing 15 3 Handling the DDO Pro Controller 15 3 1 Level 15 3 2 Key Lock 15 3 3 Utilities 15 3 4 Sub Delay 16 3 5 Delay 16 3 6 Sub Level 16 3 7 System Setup 16 3 8 Quick Guide to the V1 01 Controller s Menu Structure 17 4 Technical Specifications DDO Pro Controller 18 E Service 19 1 Maintenance 19 2 ConTour Array Spare Parts 19 3 Replacing Loudspeaker...

Page 4: ...dislodge stuck or immovable loads lift people strike knock or dent rigging frames heat treat or weld rigging frames exceed the truss s maximum load carrying capacity Note that in addition to the above specifications the operational safety regulations of VBG 9 accident prevention regulations of the German employers liability insurance association apply HK AUDIO is not responsible for damages caused...

Page 5: ...ment to be inspected at least yearly for cracks Inspect equipment used in dynamic applications for cracks every six months Maintenance You may replace easily serviceable wearing or standard parts according to the manufacturer s instructions Use original replacement parts only Tighten screws and bolted connections whenever necessary Repair If parts of the load bearing equipment become deformed it i...

Page 6: ...laration of conformity of the European Communities is the result of an examination carried out by the Quality Assurance Department of STAMER GmbH in accordance with European Standards EN 50081 1 EN 50082 1 and EN 60065 for low voltage as laid down in Article 10 of the EMC Directive Magdeburger Str 8 66606 St Wendel Lothar Stamer Dipl Ing Managing Director St Wendel 02 08 06 To the best of our know...

Page 7: ...s are out of harm s way on a recessed connector panel on the CTA 208 s back It offers two Speakon NL 4 connectors Pin assignments are pin 1 mid high 1 mid high Caution Please connect just one CT 208 to each CTA 118 Sub enclosure The second port serves to connect a power amp in parallel up to two CTA 208 at 4 ohms 1 1 Specifications CTA 208 A professional two way system featuring cylindrical wave t...

Page 8: ... frequency driver 4x 1 2 voice coil Crossover frequency 2 kHz 12 dB octave Connectors 2x Speakon NL 4 Housing birch 15 18 mm 1 2 9 13 ply Angles up 2x 4 5 Finish Black 2 component PU lacquer Grille Metal grille with black acoustic foam Handles Two slot grips routed into the side panels Rigging hardware DualCurve integrated with quick release pins Pole mount HK AUDIO DuoTilt Weight 29 kg 63 8 lbs D...

Page 9: ...rm s way on a recessed connector panel on the CTA 118 Sub s back It offers two Speakon NL 4 connectors Pin assignments are pin 1 mid high 1 mid high A Powercon mains socket with another Powercon output connects to the power supply A female XLR and a male XLR port serve to route signals Two Neutrik Ethercon ports serve to network several CTA 118 Subs 2 1 Specifications CTA 118 Sub A professional ac...

Page 10: ...t RS 485 Ethercon Woofer 18 Frequency response 10 dB 36 Hz fx Frequency response 3 dB 42 Hz fx Sensitivity 1W 1m 1 101 dB Max SPL calculated 1 134 dB 2 Max SPL peak 1 133 dB Max SPL 1 130 dB 10 THD 50 Hz 200Hz Housing birch 18 mm 3 4 13 ply Surface coating Black 2 component PU lacquer Grille Metal grille with black acoustic foam Handles 6 slot grips routed into the side panels 1 on the lid Pole mo...

Page 11: ...e Roll the case off to the side Remove the two front pins from the enclosure you wish to mount and fold down its connector component Now you can rig further cabinets Tip If you intend to rig additional enclosures we recommend that you attach all the required speaker cords to the rigging frame now because this task becomes more difficult as the array grows higher Be sure to use cords of sufficient ...

Page 12: ...13 Fig 11 a b c d e Rigging additional CTA 208 enclosures Fig 10 Hoisting the mounted CTA 208 enclosure Fig 8 Mounting the rigging frame Fig 9 Setting an intermediate angle English ...

Page 13: ...between 0 and 9 in 1 5 increments Fig 12 a b ConTour Array ground stack connectors Fig 13 ConTour Array stack plate Fig 14 a b Attaching the stackplate to the CTA 118 Sub 2 Ground stacking 3 Mains and Generator Power Supply Connect no more than two CTA 118 Subs to one mains phase 16 A If you use the Powercon Link port connect no more than one further CTA 118 Sub The 13 A limit on maximum input cur...

Page 14: ...the difference D The ConTour Array DDO Pro Controller Fig 16 DDO Pro network Fig 17 DDO Pro Controller panel Net Ports link several CTA 118 Subs in a communication network Use CAT 5 network cables or professional Ethercon cables with a metal plug to do this Connect the first CTA 118 Sub s output to the next unit s input and so forth Note This is purely a data interface The DDO Pro Net Port does no...

Page 15: ...ing meters m feet ft or milliseconds ms Select the option with the Up or Down keys and confirm your selection with Enter 3 4 Sub Delay Sub Delay is a time alignment tool that is it compensates differences in mid high units and subwoofers response times Like Sub Level Sub Delay controls subwoofers and mid high units relative delay For example if you place subwoofers well in front of mid high units ...

Page 16: ...17 Fig 19 Menu structure of the DDO PRO Controller 3 8 Quick Guide to the V1 01 Controller s Menu Structure English English ...

Page 17: ...outputs 1 2 Sampling frequency 48 kHz Bandwidth 56 bits Frequency range 20 Hz to 20 kHz 0 5 dB Dynamic range 112 A weighted 22 kHz bandwidth Interface RS 485 Ethercon Gain 96 dB to 6 dB in 0 5 dB steps Sub Level 12 dB to 6 dB in 0 5 dB steps Delay Up to 72 ms Limiter HK AUDIO DDO Multi Band Limiter ...

Page 18: ...ing and connecting a replacement speaker Red positive black negative Unfasten the voice coil housing s hex head bolts using a 3 mm wrench Take the lid off the voice coil housing Replace the voice coil Important note Replace the voice coil in a clean working environment only Be sure to keep dust and dirt out of the open driver If despite your precautions particles manage to get in use a strip of ad...

Page 19: ...tfach 1509 66595 St Wendel Germany info hkaudio com www hkaudio com International Inquiries fax 49 68 51 905 215 international hkaudio com Technische Änderungen vorbehalten Copyright 2009 2014 Music Sales GmbH 10 2014 9840172 D 2716 ...