9
English
8 Technical Data
AT 112 A:
Inputs / Outputs:
Line In L/ R: XLR female ( 1 = ground; 2 = +; 3 = - )
Input:
electronically balanced & floating
Input impedance:
47 k
Ω
Sensitivity:
0 dB
Peak input level:
+24 dB
Parallel Out L/ R:
XLR male ( 1 = ground; 2 = +; 3 = - )
Speakers:
1x 12" B&C Speaker, 1x 1" BMS driver, 60° x 40° horn
Power output:
400 watts (active)
Sound pressure level 1W/1m:
106 dB (half-space)
Max. sound pressure level / 1m:
129 dB @ 10% THD (half-space)
Directivity:
Horizontal: ± 30° ; 2kHz - 20 kHz
Vertical: ± 20° ; 3kHz - 20 kHz
Frequency response:
100 Hz - 20 kHz; ± 3 dB
Crossover frequencies:
12"/1": 1.3 kHz, 12 dB/octave
Low-cut:
(Sat/Full-range switch), 100 Hz, 24 dB/octave
Weight:
29 kg / 63.8 lbs.
Dimensions (WxHxD:
40 x 65 x 42 cm - 15 3/4" x 25 5/8" x 16 1/2"
AT 115 SUB A:
Inputs / Outputs:
Line In L/ R: XLR female ( 1 = ground; 2 = +; 3 = - )
Input:
electronically balanced & floating
Input impedance:
47 k
Ω
Sensitivity:
0 dB
Peak input level:
+24 dB
Parallel Out L/ R:
XLR male ( 1 = ground; 2 = +; 3 = - )
Speaker:
1x 15" HK AUDIO custom
Power output:
400 watts (active)
Sound pressure level 1W/1m: ^
104 dB (half-space)
Max. sound pressure level / 1m:
126 dB @ 10% THD (half-space)
Frequency response:
40 Hz - 130 Hz
Crossover:
130 Hz, 24 dB/octave
Weight:
35 kg / 77 lbs.
Dimensions (WxHxD):
48 x 65 x 64 cm - 18 7/8" x 25 5/8" x 25 1/8" incl. wheels
General electrical data:
Protection class 1
(protectively grounded/earthed)
Mains voltage 230V:
Power fuse T 2A (AT 112 A and AT 115 Sub A)
Mains voltage 117V:
Power fuse T 4A or SB 4A (AT 112 A &. AT 115 Sub A)
Mains voltage 100V:
Power fuse T 4A (AT 112 A and AT 115 Sub A)
Max. current consumption:
2.7A @230 volts
Max. power consumption:
630 VA
Mains voltage range:
+/- 10%
Ambient temperature range:
-10°C to + 60°C
Internal fuses:
4x T 4A’s
Covers are available separately for the ACTOR system’s
subwoofer and top unit.
ACTOR_BDA_2.2 01.07.2004 16:46 Uhr Seite 9 (Schwarz Bogen)