background image

ALEA 12.02.2021 

Made in Spain 

5

/

23

 

 

 

We  advise  against  installing  the  appliance  under  the  windows,  because  it  is 

favoring the heat loss. 

 

The radiator must be away, at a minimum distanceof15cmfrom any combustible 

material, curtains, furniture, chairs, etc.(Fig. 1). 

 

Allow for a minimum distance of 1 m, from the front of the unit to any obstacles 

(furniture, walls, curtains, for example) that could hinder its operation. 

 

Also keep a minimum distance of 15 cm between the appliance and the side 

walls and any other obstacles (walls, for example) that may affect its function. 

Also keep a minimum distance of 35 cm on top the appliance free of obstacles 

and a minimum distance of 15 cm from the floor. 

 

WARNING: If this appliance is installed in a bathroom, it must be installed only 

within Zones 2 or Outside Zones (Zone3), according BS 7671 Requirements for 

Electrical  Installations,  Section  701.  The  installation  of  this  appliance  within 

Zones 0 or 1 of a bathroom is totally prohibited. The figure 2 bellow is only for 

information purposes, we suggest you contact a professional electrician. 

 

 

 

- Minimum Distances  - 

 

Fig.1 

 

 

Zone 1: Appliances supplied to Safety Extra Low Voltage (SELV). 

Zone 2: Electrical Appliances Class II – IP X4 

Zone 3: Electrical Appliances protected by RCD 30mA 

 

Fig.2

 

 

SPECIFIC APPLIANCE ASSEMBLY INSTRUCTIONS 

 

• Unpack the appliance and check that neither the radiator nor the cable are 

damaged. 

• Remove the brackets from the packaging. 

• Place the radiator upside down on a carpet or other soft surface to avoid 

damaging the radiator paint layer. 

• Remove the silver screws as indicated in the following figure. 

 

 

Summary of Contents for ALEA1000

Page 1: ...ALEA 12 02 2021 Made in Spain 1 23 ORIGINAL OPERATING INSTRUCTIONS Read carefully and retain for future reference ELECTRIC RADIATOR Type ALEA Models ALEA1000 ALEA1500 ALEA2000...

Page 2: ...he nameplate of the appliance 4 Check that the power is sufficient to supply the appliances The total draw of the radiators currents must not exceed the capacity of the circuit breaker that protects t...

Page 3: ...possible to access the device s controls from the bath shower or any other surface that is in contact with water Its use in zones 0 or 1 in bathrooms is totally prohibited seek advice from a qualified...

Page 4: ...in the MAINTENANCE section because if water enters the air grilles it could seriously damage the device Do not insert any object through the grille or inside the device This radiator is designed to b...

Page 5: ...is appliance is installed in a bathroom it must be installed only within Zones 2 or Outside Zones Zone3 according BS 7671 Requirements for Electrical Installations Section 701 The installation of this...

Page 6: ...ALEA 12 02 2021 Made in Spain 6 23 Position the two wheel supports as shown in the following figure Never use the appliance without first installing the wheels...

Page 7: ...ction cables This appliance doesn t require earthing connection due it has double electrical insulation Contact a licensed electrician for assistance TECHNICAL CHARACTERISTICS Model ALEA1000 ALEA1500...

Page 8: ...ion Control Radiator Open Windows Function 1 1 Screen 1 Operation Mode The active operation mode is displayed in the box 2 Programme Number P1 to P9 U1 to U4 or System Settings Menu 01 to 11 3 System...

Page 9: ...for a few seconds ATTENTION In case the device s power disconnects the memory of the settings recorded lasts for approximately one hour After that time we recommend you check the settings installed 2...

Page 10: ...keys and and confirm with the OK key Factory setting 21 C The Timer symbol will flicker and you will see the hour day number count down until the end of the period 3 2 Manual Comfort Mode The Manual C...

Page 11: ...value It can be set in System Settings menu section 5 number 05 3 6 Program Mode Once you have selected the Program mode you can choose between nine preset programs P1 to P9 These are defined in the...

Page 12: ...ced How to edit a user programme The programming is carried out in 30 minutes slots 30 minutes 1 hour The programme editing always starts on the first day of the week 01 Monday The key activates a red...

Page 13: ...d one day durations selected 4 Specials Functions 4 1 Keypad Lock Use this function to prevent any change in the thermostat setting This is useful in areas such as children s bedrooms or public areas...

Page 14: ...s 02 Time selection 24 00 12 00 AM Antemeridian PM Post meridian 03 Automatic summer winter time change The time will change automatically The time must be changed manually You must correctly set the...

Page 15: ...or will recalibrate to ensure you achieve the comfort temperature at the time you want it 07 Open window automatic detection This function allows automatic detection of window opening see section 4 2...

Page 16: ...ours Check the wire pilot function Only France THERMAL SAFETY In the case of overheating a safety device automatically cuts the radiators operation After cooling the radiator will automatically reset...

Page 17: ...1 Morning Afternoon Weekend P2 Morning Noon Evening Weekend P3 Week Weekend P4 Afternoon Weekend P5 Morning Afternoon Bathroom P6 Morning Afternoon Weekend P7 7H 19H Office P8 8H 19H Saturday Shop P9...

Page 18: ...the following equipment complies with all the essential requirements for health and safety of European Directives 2014 30 EC EMC DIRECTIVE 2014 35 EC LV DIRECTIVE 2011 65 UE RoHS DIRECTIVE 2009 125 E...

Page 19: ...heat output and no room temperature control NO Maximum continuous heat output Pmax c 2 kW Two or more manual stages no room temperature control NO Auxiliary electricity consumption with mechanic therm...

Page 20: ...control with presence detection NO Maximum continuous heat output Pmax c 1 5 kW room temperature control with open window detection YES Auxiliary electricity consumption with distance control option...

Page 21: ...inuous heat output Pmax c 1 kW Auxiliary electricity consumption At nominal heat output elmax 1 kW In standby mode elSB 0 0005 kW The seasonal heating energy efficiency of this local space heater is S...

Page 22: ...se the recycling of the components and materials that comprise it and reduce the impact on human health and the environment The crossed out wheeled bin is marked on all Electrical and Electronic produ...

Page 23: ...by HERMANOS JULIAN M S L Head Office Esposos Curie 44 Factory Gutenberg 91 93 Pol gono Industrial Los Villares 37184 Villares de la Reina Salamanca Espa a Tf 34 923 222 277 34 923 222 282 Fax 34 923 2...

Reviews: