background image

En-7

TIMER OPERATION

To Use the  OFF TIMER

1

Press the START/STOP button (Fig. 6 

S

)

(if the unit is already operating, proceed to step 2).

The Indoor Unit’s OPERATION Indicator Lamp (red) (Fig. 3 

5

) will light.

2

Press OFF TIMER button  (Fig. 6 

N

) to select the de-

sired times.

Press OFF TIMER button to change from temperature setting to timer dis-
play.
Each time the button is pressed, the time changes in the following order:

Set the time while the OFF TIMER mark (

) on the remote control

unit’s display is flashing. (The flashing will continue for about 30 sec-
onds)

3

Press SET button (Fig. 6 

P

) to select OFF TIMER op-

eration.

The OFF Timer Mark  (

) will be shown on the remote control unit’s

display.
The Indoor Unit TIMER Indicator Lamp (green) will light.
It can not be used during ON TIMER operation.

To Use the ON TIMER

1

Press the START/STOP button (Fig. 6 

S

)

(if the unit is already operating, proceed to step 2).

The Indoor Unit’s OPERATION Indicator Lamp (red) (Fig. 3 

5

) will light.

2

Press ON TIMER button (Fig. 6 

O

)  to set the expected

time.

If ON TIMER button is pressed, it will be changed into time display from
temperature setting display.
Each time the button is pressed, the time time changes in the following
order:

Set the time while the ON TIMER mark (

)on the remote control unit’s

display is flashing.(The flashing will continue for about 30 seconds)

3

Press SET button (Fig. 6 

P

) to select ON TIMER opera-

tion.

The ON Timer mark (

)will be shown on the remote control unit’s dis-

play.
The Indoor Unit Timer Indicator Lamp(green) Will light.
It can not be used during OFF TIMER operation.

To Cancel the Timer

Press the CANCEL TIMER button.

To Change the Timer Settings

Press the ON TIMER button/OFF TIMER
button as required. Perform Use TIMER
step 2 and 3.

To Stop Air Conditioner Operation
while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change the operating
conditions (Mode, Fan Speed, Thermostat
Setting), after making the timer setting,
wait until the entire display reappears, then
press the appropriate buttons to change to
the desired operating condition.

To Cancel the Timer

Press the CANCEL TIMER button.

To Change the Timer Settings

Press the ON TIMER button/OFF TIMER
button as required. Perform Use TIMER
step 2 and 3.

To Stop Air Conditioner Operation
while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting),
after making the timer setting wait until the
entire display reappears, then press the
appropriate buttons to change the operat-
ing condition desired.

9312175017-01_en.pm6.5

03.7.29, 9:33 AM

7

www.enindel.com

Summary of Contents for HOW-7UB

Page 1: ...liano E vIk OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI MANUAL DE INSTRU ES P N9312855018 01 ROOM AIR CONDITIONER WALL MOUNTED TYPE HEAT COOL MODE...

Page 2: ...cord are required Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from t...

Page 3: ...oner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s In...

Page 4: ...TART STOP button T AIR FLOW DIRECTION button U SWING LOUVER button V ACL button W TEST RUN button This button is used when installing the conditioner and should not be used un der normal conditions as...

Page 5: ...range becomes appre ciably reduced replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object Turn on the Power 1 Connect the Power Supply Plug Fig 1 C to an...

Page 6: ...e To Set the Fan Speed Press the FAN CONTROL button Fig 6 R Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire di...

Page 7: ...eed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temper...

Page 8: ...k on the remote control unit s display is flashing The flashing will continue for about 30 seconds 3 Press SET button Fig 6 P to select ON TIMER opera tion The ON Timer mark will be shown on the remot...

Page 9: ...in accordance with the time setting When the time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically rai...

Page 10: ...ing range for more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be con...

Page 11: ...utes the unit will automatically switch the swing range to the horizontal flow range to prevent the condensation of moisture on the outlet MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the ev...

Page 12: ...ose the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the Air Filter either with a vacuum cleaner or by washing the fil...

Page 13: ...n and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan sp...

Page 14: ...ash Heating Performance This air conditioner operates on the heat pump princi ple absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as...

Page 15: ...damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do no...

Page 16: ...9312175017 01_Pt pm6 5 03 7 29 9 39 AM 15 www enindel com...

Reviews: