background image

KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE

English

Deutsch

Français

Español

Italiano

EλληvIkά

OPERATING MANUAL
BEDIENUNGSANLEITUNG
MODE D’EMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI

ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ

MANUAL DE INSTRUÇÕES

РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

P/N9312855018-01

ROOM AIR CONDITIONER

WALL MOUNTED TYPE

HEAT & COOL MODEL
(REVERSE CYCLE)

Por

tuguês

Ру

сс

кий

9312855018_Cover.pm6.5

03.7.29, 10:55 AM

1

www.enindel.com

Summary of Contents for HOW-7UB

Page 1: ...liano E vIk OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI MANUAL DE INSTRU ES P N9312855018 01 ROOM AIR CONDITIONER WALL MOUNTED TYPE HEAT COOL MODE...

Page 2: ...cord are required Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from t...

Page 3: ...oner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s In...

Page 4: ...TART STOP button T AIR FLOW DIRECTION button U SWING LOUVER button V ACL button W TEST RUN button This button is used when installing the conditioner and should not be used un der normal conditions as...

Page 5: ...range becomes appre ciably reduced replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object Turn on the Power 1 Connect the Power Supply Plug Fig 1 C to an...

Page 6: ...e To Set the Fan Speed Press the FAN CONTROL button Fig 6 R Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire di...

Page 7: ...eed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temper...

Page 8: ...k on the remote control unit s display is flashing The flashing will continue for about 30 seconds 3 Press SET button Fig 6 P to select ON TIMER opera tion The ON Timer mark will be shown on the remot...

Page 9: ...in accordance with the time setting When the time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically rai...

Page 10: ...ing range for more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be con...

Page 11: ...utes the unit will automatically switch the swing range to the horizontal flow range to prevent the condensation of moisture on the outlet MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the ev...

Page 12: ...ose the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the Air Filter either with a vacuum cleaner or by washing the fil...

Page 13: ...n and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan sp...

Page 14: ...ash Heating Performance This air conditioner operates on the heat pump princi ple absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as...

Page 15: ...damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do no...

Page 16: ...9312175017 01_Pt pm6 5 03 7 29 9 39 AM 15 www enindel com...

Reviews: