Emergency and Test Operation
Termination of emergency or test operation:
Operation
Test operation:
Use this switch in the test operation when the room
temperature is below 16
O
C
, do not use it in the normal
operation.
Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch: the cooling operation
starts with the air flow speed "Hi".
After 30 minutes, test opretation ends automatically.
Press the emergency operation switch once more, or manipulate through the
remote controller; the "Pi" sound, the emergency or test operation is terminated.
When the remote controller is manipulated, it gets the system back to the normal
operation mode.
Test operation switch is the same as emergency switch.
Emergency operation:
Use this operation only when the remote controller is
defective or lost.
When the emergency operation switch is pressed,the
" Pi "sound is heard once, which means the start of this
operation.
In this operation , the system automatically selects the
operation modes, cooling or heating , according to the
room temperature , as follows .
It is not possible to operate in dry mode.
Temperature
Designated
temperature
Air
flow
BELOW 23
O
C
CONTINUOUS AUTOMATIC
Operation
mode
Timer
mode
COOLING
HEATING
26
O
C
23
O
C
ABOVE 23
O
C
AUTOMATIC
CONTINUOUS
Pi...Pi.Pi
Pi
En-18