![Hix HT-400P Owner'S Manual Download Page 4](http://html1.mh-extra.com/html/hix/ht-400p/ht-400p_owners-manual_2140540004.webp)
4
2. Press the “UP” or “DOWN” button to change Auto Shut Off Time to
desired Auto Shut Off Time, up to 12 hours in 1/2 hour increments. A
setting of 5=1/2 hour, 10=1 hour, 15=1-1/2 hours, 40=4 hours, etc. A
setting of Zero will disable the feature.
3. Press the “Menu” button once to lock in the new setting.
4. Wait 15 seconds for the controller to automatically exit the “Program-
ming Mode”.
1. The pressure control knob, located on the top of
the machine, should be set so that the heat head
will lock down firmly.
2. Pressure is reduced by turning knob (with machine
open)
counter-clockwise
and increased by
turning it
clockwise
.
3. The amount of platen pressure can be monitored on the controller
with the display labeled “Platen Pressure.” A value between 0-9 will be
displayed when the machine is closed indicating the amount of platen
pressure on the machine. Values of 0-3 indicate “light” pressure, 4-6
“medium” pressure and 7-9 “heavy” pressure. If the value exceeds 9
then a “-” will appear in the display indicating that the maximum value
that can be displayed has been exceeded.
NOTE:
Adjustments may be required from one garment to another and will
vary to achieve the desired result.
WARNING: Excessive pressure can cause structural damage, voiding
the machine warranty!
ATTENTION: Pression excessive peut endommager la machine et
annuler la garanti.
The 120 volt models have a slower heat recovery (i.e. 18-20 seconds @
375°F). The 220 volt models are recommended for quicker cycle times (i.e.
10 seconds @ 375°F).
1. Set the temperature, time, & pressure to the desired settings as
instructed.
Always
consult your specific transfer recommendations.
Typical settings are;
Cold Peel:
350°F (177°C), 15 seconds and
Hot
Split:
375°F (190°C), 10-12 seconds.
2. Align substrate on lower platen. Smooth wrinkle from garments.
NOTE:
Wrinkles may be removed by bringing the heated platen in contact
with the garment for a few seconds before the transfer is positioned.
AUTO SHUT OFF FEATURE
PRESSURE
TRANSFER APPLICATION
Pressure knob