32
Assembly and connection
Assembly Instructions
Linear Axes HM-S and HT-S
HMS_HTS-01-0-EN-1905-MA
Observe the L
SY
hole spacing (Fig. 6.17) when securing linear axes.
6.1.5 Mounting with clamping profiles – linear modules HM-S
Precision requirements for all reference surfaces for securing the axis profile.
L
SY
L
B
F
A
0.2 mm/m
L
SX
L
SY
40
L
SX
L
SY
40 40
The clamping profiles must always be attached in pairs to the left and right of the axis body (see Fig. 6.18 and Fig. 6.19). The
required minimum number must be taken from Table 6.3. The required number of clamping profiles depends on the external
load. To calculate the required number, the load values listed in Table 6.3 (clamping force per clamping profile; permissible
axial operating force in tension direction per clamping profile) must be taken into account. Don’t drop below the minimum
number of clamping profiles specified in Table 6.3. The distances between the mounting points are to be selected depending
on the load situation. The recommended distances L
SX
listed in Table 6.3 are only reference values.
Drill mounting holes in the mounting surface (hole spacing listed in Table 6.3).
Clean mounting surface and position linear axis on it.
Swivel the clamping profile into the side groove.
Secure the clamping profile with a small tightening torque on the bolts.
Now tighten the bolts with the full tightening torques, proceeding in a crosswise manner.
The linear axis has now been installed.
Fig. 6.17
Hole spacing for the lateral securing of linear modules HM-S with clamping profiles
Fig. 6.18
Securing with clamping profiles – HM040S, HM060S, HM080S
Fig. 6.19
Securing with clamping profiles – HM120S
Summary of Contents for HM-S
Page 99: ......