Assembly and connection
31
Assembly Instructions
Linear Axes HM-S and HT-S
HMS_HTS-01-0-EN-1905-MA
Fig. 6.13
Permissible axial operating force in tension direction per slot nut (F
A
_perm.)
F
A_perm.
L
NX
L
NY
L
NX
L
NY
L
NX
L
NY2
L
NY1
Size
Minimum
number
of T nuts
L
NY
/L
NY1
[mm]
L
NY2
[mm]
Recommended
distance L
NX
[mm]
Thread
size
Screw tightening
torque
[Nm]
Clamping
force per T
nut [N]
F
A_perm.
1)
[N]
Art. no.
T nuts
(10 pcs)
HT100S
8
80
—
500
M5
4.5
5,400
500
20-000529
HT150S
8
120
—
600
M6
10.1
10,200
1,750
20-000531
HT200S
12
160
—
800
M8
24.6
18,600
5,000
20-000534
HT250S
16
210
130
1,000
M8
24.6
18,600
5,000
20-000534
1)
Permissible axial operating force in tension direction per T nut
Table 6.2
Minimum number of T nuts for securing the axis, and recommended spacing of mounting points on long
axes – linear tables HT-S
Fig. 6.14
Securing with T nuts – HT100S, HT150S
Fig. 6.15
Securing with T nuts – HT200S
Fig. 6.16
Securing with T nuts – HT250S
Summary of Contents for HM-S