![HIVILUX TXN Series User Manual Download Page 8](http://html1.mh-extra.com/html/hivilux/txn-series/txn-series_user-manual_2140412008.webp)
P O W E R J A C K
S Y NCHRONIZATION
T R IGGER
P R O J E C T O R
P O W E R P LUG
CONTROL METHODS
Learning button
DC/manual control port/RS485 port
AC port AC110V
~
240V
7
Blue(up)
Yellow and Green(down)
Brown(common wire)
AC central
control
868 MHz Inner Wireless Control
868 MHz inner wireless control system can be connected to RS 485 control , DC
central control (DC5V-12V)and manual control. This device applicable to
multivoltage(AC110V- 240V)
Synchronizer(optional)
AC Central Control Circuit Diagram
Code Learning:
Connect the Sync- Trigger with projector and power cable,then switch on.Press the
LEARNING KEY(on the end cap)for 4s then loose. The screen will automatically
going up and down once. Press the SET KEY on the Sync-Trigger, Screen
automatically up and down once while the LED LIGHT flashing, code learning is
completed.
Code Erasion:
Press the learning button at the end cap for 7 seconds, then press again, screen
automatically move up and down twice, original code has erased. Refer to point A in
page 4 to reset new code.