![HITROL HPC-100CT-2 Series Instruction Manual Download Page 4](http://html.mh-extra.com/html/hitrol/hpc-100ct-2-series/hpc-100ct-2-series_instruction-manual_2140198004.webp)
HT(HPC)-100CT-2 Series
HITROL CO., LTD. 4
Specifications Weather-Proof Version
Model
HT-100CT-2
HT-100CTH-2
HT-100CTW-2
HT-100CTWH-2
Probe Type
Rod
Wire
Mounting
Screw or Flange
Ambient Temperature
-20°C ~ +60°C
Process Temperature
-40°C~+80℃
-40°C~+150℃
-40°C~+80℃
-40°C~+150℃
Process Pressure
Vacuum~ 20kg/cm2(300#)
Power Source
DC 24V
Output
DC 4~20mA(2-wire)
Enclosure
Weather-Proof
Wetted Parts Material
SUS 304, 316L with Teflon
Process Connection
PT 1”(M) Screw
50A JIS 10K RF Flange
Housing ; Cable Entry
PBT;PF1/2”(F),IP65
AL.; PF 1/2
''
(F), IP66
PBT;PF1/2”(P),IP65
AL.; PF 1/2
''
(F), IP66
AL;PF1/2”(F),IP66
AL;PF1/2”(F),IP66
Accuracy
Up to ±1% of F.S
Ex-Proof Version
Model
HPC-100CT-2
HPC-100CTH-2
HPC-100CTW-2
HPC-100CTWH-2
Probe Type
Rod
Wire
Mounting
Screw or Flange
Ambient Temperature
-20°C ~ +60°C
Process Temperature
-40°C~+80℃
-40°C~+150℃
-40°C~+80℃
-40°C~+150℃
Process Pressure
Vacuum~ 20kg/cm2(300#)
Power Source
DC 24V
Output
DC 4~20mA(2~wire)
Enclosure
Ex-Proof
(Ex d IIC T6, IP65)
Ex-Proof
(Ex d IIC T4, IP65)
Ex-Proof
(Ex d IIC T6, IP65)
Ex-Proof
(Ex d IIC T4, IP65)
Wetted Parts Material
SUS 304, 316L with Teflon
Process Connection
PT 1”(M) Screw
50A JIS 10K RF Flange
Housing ; Cable Entry
AL. ; PF 3/4”(F)
Accuracy
Up to ±1% of F.S
Summary of Contents for HPC-100CT-2 Series
Page 15: ...2 Specification Table 1 Specification ...
Page 16: ...3 Configuration of Setting Menu Table 2 Setting Menu List ...
Page 17: ...4 Setting and Operating LCD Configuration Into the Setting Menu Return to Setting Mode ...
Page 18: ... Select the Setting Menu Change the User Setting Table 3 Key Button Guidance ...
Page 20: ... Zero Span Capacity fine Adjustment Zero Setting Span Setting Span Setting Other ...