Sensitivity Adjustment 

Use only with electrode sensors. 

Note that factory standard setting is for high sensitivity. 

 

Sensitivity 
Adjustment & 
Recommended 
Tool (HLC-200A) 
 
 
 
                                                                                                                                                         
                                               
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Recommended Tool 

 

- When adjusting 

SENS. 

(Sensitivity), use the driver 

(-) 2.5x75 or less

 or 

(+)

 

00x75

- Alarm Lamp: The red light is on when the liquid is detected, and the green light is on 

when the liquid is not detected. 

-  Sensitivity  Dial:  It  is  a  function  to  adjust  the  sensitivity  in  condition  that  it  is  too 

sensitive to the conductivity of the medium or foam. Turning counter-clockwise is for 

higher sensitivity and clockwise is for lower sensitivity. 

 

 

Sensitivity Dial

 

High Sensitivity

 

Low Sensitivity

 

 

Default Status

 

Detector Status

 

Alarm Lamp

 

Maximum available adjustment range of potentiometer using for the sensitivity 

dial is approximately 260°. (

±

130° based on 9 o’clock direction) 

Pay attention to use it because it can be damaged if it is adjusted over the range. 

 

Summary of Contents for HLC-200A

Page 1: ...ICE FACTORY R D INSTITUDE HITROL CO LTD 141 Palhakgol gil Jori eup Paju si Gyeonggi do Korea TEL 82 31 950 9700 FAX 82 31 943 5600 www hitrol com INSTRUCTION MANUAL LEVEL CONTROLLER ALARM UNIT HLC 200...

Page 2: ...o carry outthework Table of Contents Overview 3 Characteristics 3 Operating Principle and Composition 3 Specifications 4 HLC 200A 4 HLC 200F 4 Dimensions 4 Installation and Wiring 5 Installation 5 HLC...

Page 3: ...ructure type for freely detachment Operating can be checked through LED lamp High Red Low Green Sensitivity can be adjusted at the site if the sensor is too much sensitive to the conductivity or foam...

Page 4: ...0 Power Source AC 110V or 220V 50 60Hz DC 24V DC 21V DC 30V Standby Power Consumption AC 110V 0 5W AC 220V 0 8W DC 24V 0 48W Active Power Consumption AC 110V 1 4W AC 220V 2W DC 24V 1 1W Output Voltage...

Page 5: ...allation and Wiring Control Drain Pump LED Color Red Green Input 1 3 4 1 3 4 Output 8 5 8 6 Alarm H A L A LED Color Red Green Input 1 4 1 4 Output 8 5 8 6 1 Install the socket DIN Rail 2 Fix it using...

Page 6: ...HLC 200 Series HITROL CO LTD 6 HLC 200F Wiring Control Drain Pump LED Color Red Green Input 1 3 4 1 3 4 Output 8 5 8 6 Alarm H A L A LED Color Red Green Input 1 4 1 4 Output 8 5 8 6 Connection Diagram...

Page 7: ...the liquid is not detected Sensitivity Dial It is a function to adjust the sensitivity in condition that it is too sensitive to the conductivity of the medium or foam Turning counter clockwise is for...

Page 8: ...Power off Release the Locker Body Disconnection Wiring Disconnection Socket Disconnection It is recommended to use washers to prevent a loosening when the product is fixed using bolts Wiring shall be...

Page 9: ...mber and matters regarding input output The serial number is a unique manufacturing number for the identification of products Controller is normal but not working 1 Electrode Type Level Switch If ther...

Reviews: