Purpose of the Manual 

 

 

This manual and the instruction documents of refrigeration lines, wiring diagrams and any other attached documents, 
have been written to allow a correct installation, set up and maintenance of the unit. Therefore it is essential to read the 
instructions with due attention. Verify all the necessary information for the correct installation of the system is included 
in the manuals supplied with this unit and / or the rest of the indoor units, accessories, etc. Otherwise, the manufacturer 
declines any responsibility for any damage to persons or things, as a result of improper use of the unit and/or failure to 
observe these instructions. 

 
Preservation Manual 

 

This manual and the electric diagram of the unit must be retained and remain available to the operator for any further consultation. 
 

Updating the Data 

 

The continuous improvement in design and performance to which we are committed gives us the right to modify the specifications of our 
products without prior notice. 

 

 

Electrical Network 

 

 

Check that electrical network features are in accordance to data shown in the data nameplate of the unit. 

 
Local Safety Regulations 

 

Observe and analyze all possible causes of accidents that may arise in the place or places of installation of the units, check means and 
tools to use, etc. It is not possible to anticipate each and every one of the potential circumstances of danger in this manual. Respect the 
local security standards during installation. 

 

Principles of Security on Installation 

 

The unit is designed and built in a way that does not pose a risk to the health and safety of people. Appropriate project solutions have 
been adopted to eliminate the possible causes of risk in the installation. 

 
Packaging and Replacement of Equipment 

 

 

The packaging material (plastic bags, insulating materials, nails, etc.) is a potential source of danger and should be kept 
out of the reach of children and properly recycled according to local safety regulations. This product should not be mixed 
with household waste at the end of its life. Due to the refrigerant, oil and other components contained in this product, it 
must be dismantled by professional installers in accordance with current regulations. 

 

Use 

 

The  unit  will  be  used  only  for  the  reason  has  been  conceived.  Any  other  use  does  not  imply  any  kind  of  compromise  or  link  for  the 
manufacturer. 

 
Incorrect Operation 

 

In case of breakdowns or operation faults, turn off unit. 
 

Periodic Inspections and Maintenance 

 

 

Carry out periodic inspections to detect possible damaged or broken pieces. If they are not  repaired it could result in 
damage to people or stuff. Before executing any maintenance operation, cut off the unit power supply.  

All operations must be carried out in accordance with local safety regulations. 

 
Repairs 

 

 

Reparations should be always realized for trained personal authorized by the manufacturer using original spares. Failure 
to comply with these warnings could affect the safety features of the unit. 

 
Modifications 

 

All  manufacturer  responsibility  is  declined  when  the  warranty  has  been  expired  in  case  of  electrical  and/or  mechanical  modifications. 
Alterations in general not expressly allowed and not respecting what is instructed here, they cause the warranty expiration. 
 

Refrigerant 

 

This product is hermetically sealed and contains R-410A which is a HFC fluorinated greenhouse gas. 

Summary of Contents for EKWXA 1001.1

Page 1: ...ance Manual 07 17 207443 Rev 105 EKWXA EKWXBA AIR COOLED WATER CHILLERS AXIAL FANS Models 801 1 1001 1 1201 1 1501 1 Cooling Capacities from 21 18 kW to 38 7 kW Heating Capacities from 25 2 kW to 40 3...

Page 2: ...efficiency adaptability usability and practical solutions This has been the hallmark of our product catalogue The versatility of our factory allows us to contribute solutions almost tailored to each p...

Page 3: ...INSTALLATION LOCATION 11 UNIT SETTLEMENT 11 WATER DRAIN 11 SECURITY ELEMENTS 11 ELECTRICAL CONNECTIONS 11 SERVICE AREA 12 OPERATION 12 OPERATING LIMITS 12 Refrigeration Mode 13 Heat Pump Mode 13 BEFOR...

Page 4: ...built in a way that does not pose a risk to the health and safety of people Appropriate project solutions have been adopted to eliminate the possible causes of risk in the installation Packaging and...

Page 5: ...be dangerous because the system is under pressure because some of its elements have high temperatures and include electrical components Do not install the unit in explosive atmosphere ATTENTION Only...

Page 6: ...73 EER 2 85 2 69 2 85 2 46 Evaporator water flow m h 3 65 4 30 4 96 6 69 Evaporator pressure drop kPa 24 70 32 90 27 10 45 00 Heating capacity 2 kW 25 20 29 30 33 70 40 30 Total absorbed capacity 3 kW...

Page 7: ...minum fin coil and copper tubing Quantity 1 1 1 1 Front surface of the exchanger m2 1 49 1 49 1 49 1 49 INDOOR HEAT EXCHANGER Type Water Refrigerant Quantity 1 Water volume L 2 3 2 9 3 4 3 4 Anti ice...

Page 8: ...d and stable bear in mind that the heaviest part is where the compressor is installed Always transport the unit in its original packaging to the place of installation Lifting through crane STORAGE If...

Page 9: ...TER CHILLERS AXIAL FANS INSTALLATION DIMENSIONS Models 801 1 1501 1 1 Water inler 1 1 2 2 Water outlet 1 1 2 3 Electrical panel 4 Main switch 5 Electrical connection input 6 Optional electrical connec...

Page 10: ...AXIAL FANS INSTALLATION WEIGHT DISTRIBUTION Models 801 1 1501 1 GRAVITY CENTER cm WEIGHT DISTRIBUTION kg X Y P1 P2 P3 P4 Total 801 1 46 53 102 71 57 82 312 1001 1 46 54 109 78 64 90 340 1201 1 48 55 1...

Page 11: ...ectrical heating wire to avoid water freezing and tube damage It is convenient to install the trap with proper dimensions SECURITY ELEMENTS The installation of the following safety elements when NOT i...

Page 12: ...MUM MAXIMUM Water Outlet 25 C 55 C Outdor Air Wet Bulb 10 C 22 C For lower temperatures it is necessary to use the water mixture with glycol For lower temperatures use the optional condensing control...

Page 13: ...15 10 5 LWT C Temperatura exterior 7 10 5 0 5 10 15 20 25 20 10 0 10 20 30 40 55 LWT C Temperatura exterior Outdoor temperature T mperature xterieur C 46 20 10 15 10 0 10 20 30 40 46 Temperatura exte...

Page 14: ...al icons that show all the desired information on the same screen Operation Mode 1 compressor olny cooling and heat pump Defrost maneuver by pressure transducers Management of the recirculation pump a...

Page 15: ...rost exceeded Notification A50 Fan thermal protection Automatic OFF OFF OFF A61 Maximum service hours for compressor 1 exceeded Notification AC0 General Thermal Compressor Alarm Manual OFF OFF OFF OFF...

Page 16: ...400 3 50 Number of Water Pump 1 Reserve Water Pump Option NO Maximum weight Heat Pump H K full of water kg 447 475 483 489 LOW PRESSURE PUMP Model 120 3 Rated Power per unit kW 0 55 Maximum Current O...

Page 17: ...hermal expansion Water between 7 55 C 2 bar V V 0 015 Expansion vessel l 11 Maximum water volume 7 50 C l 438 Maximum water volume 7 55 C l 368 WEIGHT DISTRIBUTION Models 801 1 1501 1 MINI KRONO 2 Ser...

Page 18: ...synthetic oils are mixed with minerals or alkylbenzenes they deteriorate causing capillary blockage or failure in the compressor Do not mix under any circumstances REFRIGERANT CHARGE In case it is nec...

Page 19: ...KIT Option 1 Pump Tank Expansion vessel Option 2 Pump Tank with electrical heater Expansion vessel In HEAT mode for low outdoor temperatures the electric heater is activated as a compressor support as...

Page 20: ...cur An individual exposed to high concentrations of R410A must be given medical attention immediately Adequate ventilation must be provided at all times Recommendations Semiotics or support therapy is...

Page 21: ...emperature below 52 C Protective Clothing Wear overalls protective gloves and goggles or a mask Accidental Release Measures IIt is important to wear protective clothing and a respirator Stop the sourc...

Page 22: ...22 07 17 207443 Rev 105 EKWXA EKWXBA AIR COOLED WATER CHILLERS AXIAL FANS We reserve the right to add modifications without prior notice...

Reviews: