![HITEC HFP-30 Instruction Manual Download Page 2](http://html1.mh-extra.com/html/hitec/hfp-30/hfp-30_instruction-manual_2139917002.webp)
Dial Button
AUTO-Extreme
With this highlighted, press the Adjust Dial. This will select the Test
Mode and show a ‘Pause’ indicator in the lower right of the screen.
Pressing the Adjust Dial again will select ‘Play’ and the servo will
start moving. The servo speed is adjusted by turning the Adjust Dial.
Press the Adjust Dial to ‘Pause’ or the BACK button to switch to a
different Auto Test Mode.
AUTO-Sweep
With this highlighted, press the Adjust Dial. This will select the Test
Mode and show a ‘Pause’ indicator in the lower right of the screen.
Pressing the Adjust Dial again will select ‘Play’ and the servo will
start moving. The cycle speed is adjusted by turning the Adjust Dial.
Press the Adjust Dial to ‘Pause’ or the BACK button to switch to a
different Auto Test Mode.
AUTO-Step
With this highlighted, press the Adjust Dial. This will select the Test
Mode and show a ‘Pause’ indicator in the lower right of the screen.
Pressing the Adjust Dial again will select ‘Play’ and the servo will
start moving. The Step increments are adjusted by turning the Adjust
Dial.
Press the Adjust Dial to ‘Pause’ or the BACK button to switch to a
different Auto Test Mode.
AUTO-DB (Deadband)
Use the Adjust Dial to highlight AUTO-DB and press it to enter the
menu. The Auto Test will check the servos Deadband. When in the
menu, press the Adjust Dial to begin the Test. A ‘Play’ symbol will be
displayed in the lower right screen. Turning the Adjust Dial will adjust
the microsecond range. The jitter range is 0.25 microseconds to
100.0 microseconds.
Press the BACK button to exit.
Dial Button
Dial Button
In this mode, all manufacturer’s servos can be tested for operation.
To begin testing servos, plug a servo into the servo slot on the
programmer and install the correct battery type in the battery slot.
Move the select switch to the TEST position.
1. Manual test
Using the Adjust Dial, highlight Manual, and press then Adjust
Dial to enter.
At this point it is possible to move the servo using the Pulse Dial.
As the dial is turned the OUTPUT box will show the current position
of the servo in microseconds.
Pressing the Adjust Dial will switch to STEP mode allowing much
finer control. Use the Adjust Dial to adjust the microseconds. Press
again to exit.
Press the BACK button to exit the menu.
1. AUTO – E/S/S Test (Extreme, Sweep, Step)
Use the Adjust Dial to highlight AUTO – E/S/S and press it to
enter the menu.
In the Auto Test menu, it is possible to switch between Extreme,
Sweep, and Step modes by turning the Adjust Dial. Each mode will
display a cycle count and how much time has passed during the
test. Before a mode is selected, the Pulse Dial will move the servo
manually.
Here’s a brief explanation of the different modes:
Extreme – Moves the servo through minimum, middle (neutral),
and maximum endpoints. Speed of the total movement can be
adjusted. If the movement is set faster than the servo is rated,
then the servo will not be able to move to each end point before
changing direction. The speed ranges from 0.1 second to 5.0
second.
Sweep – Moves the servo through minimum and maximum
endpoints at an adjustable speed. The speed of the Sweep is
adjustable between 2.4 seconds/cycle to 120 seconds/cycle.
Step – Moves the servo through the minimum and maximum
positions at an adjustable Pulse Step. The Step range is 0.25
microseconds to 100.0 microseconds.
Dial Button
Test Mode
Dial Button
Dial Button
Main Servo Test Screen
Use the Adjust Dial to select the desired test function. Once the
function is highlighted, press the Adjust Dial to enter.