Dial Button

AUTO-Extreme

With this highlighted, press the Adjust Dial. This will select the Test 

Mode and show a ‘Pause’ indicator in the lower right of the screen. 

Pressing the Adjust Dial again will select ‘Play’ and the servo will 

start moving. The servo speed is adjusted by turning the Adjust Dial. 

Press the Adjust Dial to ‘Pause’ or the BACK button to switch to a 

different Auto Test Mode.      

AUTO-Sweep

With this highlighted, press the Adjust Dial. This will select the Test 

Mode and show a ‘Pause’ indicator in the lower right of the screen. 

Pressing the Adjust Dial again will select ‘Play’ and the servo will 

start moving. The cycle speed is adjusted by turning the Adjust Dial.

Press the Adjust Dial to ‘Pause’ or the BACK button to switch to a 

different Auto Test Mode. 

AUTO-Step

With this highlighted, press the Adjust Dial. This will select the Test 

Mode and show a ‘Pause’ indicator in the lower right of the screen. 

Pressing the Adjust Dial again will select ‘Play’ and the servo will 

start moving. The Step increments are adjusted by turning the Adjust 

Dial.

Press the Adjust Dial to ‘Pause’ or the BACK button to switch to a 

different Auto Test Mode.

AUTO-DB (Deadband)

Use the Adjust Dial to highlight AUTO-DB and press it to enter the 

menu. The Auto Test will check the servos Deadband. When in the 

menu, press the Adjust Dial to begin the Test. A ‘Play’ symbol will be 

displayed in the lower right screen. Turning the Adjust Dial will adjust 

the microsecond range. The jitter range is 0.25 microseconds to 

100.0 microseconds.

Press the BACK button to exit.

Dial Button

Dial Button

In this mode, all manufacturer’s servos can be tested for operation. 

To begin testing servos, plug a servo into the servo slot on the 

programmer and install the correct battery type in the battery slot. 

Move the select switch to the TEST position.

1.  Manual test 

Using the Adjust Dial, highlight Manual, and press then Adjust 

Dial to enter.

At this point it is possible to move the servo using the Pulse Dial. 

As the dial is turned the OUTPUT box will show the current position 

of the servo in microseconds.

Pressing the Adjust Dial will switch to STEP mode allowing much 

finer control. Use the Adjust Dial to adjust the microseconds. Press 

again to exit.

Press the BACK button to exit the menu.

1.  AUTO – E/S/S  Test (Extreme, Sweep, Step) 

Use the Adjust Dial to highlight AUTO – E/S/S and press it to 

enter the menu. 

In the Auto Test menu, it is possible to switch between Extreme, 

Sweep, and Step modes by turning the Adjust Dial. Each mode will 

display a cycle count and how much time has passed during the 

test. Before a mode is selected, the Pulse Dial will move the servo 

manually.

Here’s a brief explanation of the different modes:

Extreme – Moves the servo through minimum, middle (neutral), 

and maximum endpoints. Speed of the total movement can be 

adjusted. If the movement is set faster than the servo is rated, 

then the servo will not be able to move to each end point before 

changing direction. The speed ranges from 0.1 second to 5.0 

second.

Sweep – Moves the servo through minimum and maximum 

endpoints at an adjustable speed. The speed of the Sweep is 

adjustable between 2.4 seconds/cycle to 120 seconds/cycle.

Step – Moves the servo through the minimum and maximum 

positions at an adjustable Pulse Step. The Step range is 0.25 

microseconds to 100.0 microseconds.

Dial Button

Test Mode

Dial Button

Dial Button

Main Servo Test Screen

Use the Adjust Dial to select the desired test function. Once the 

function is highlighted, press the Adjust Dial to enter.