-6-
Fig. 11 •
Reassembly of housing (A).(B) set (2)
Fit the Hammer Case
[7]
in housing (A) securely.
Hammer Case
[7]
Protrusion (for locking)
Fit the protrusion of housing (A) in the notch
of the Motor DC 12 V
[23]
(for locking).
Fit the protrusion of the Hammer Case
[7]
(for
locking) in the concave portion of housing (A).
Fig. 12 •
Mounting the guide sleeve
4. Mounting the exterior parts
Cover the assembled housing with the Front Cap
[6]
.
5. Mounting the guide sleeve
Insert one Steel Ball D3.175
[8]
into the hole of the Anvil
[9]
. Mount Guide Sleeve (C)
[5]
, Guide Spring (C)
[4]
and
Washer (F)
[3]
in sequence. Mount the Retaining Ring
[2]
into the groove of the anvil using J-339 jigs (E) and (F) for
retaining rings.
NOTE: Be sure to replace the Retaining Ring [2] with
a new one because it may be deformed and
Guide Sleeve (C) [5] could come off if the
deformed Retaining Ring [2] is used again.
Push down.
J-339 jig (E)
for retaining rings
Retaining Ring
[2]
Washer (F)
[3]
J-339 jig (F)
for retaining rings