6 - 8
6-4-1 CDS sampling pulse adjustment
Incompleted Phenomenon
Diagonal beats and horizontal noise occur.
Condition:
Leave the video camera for more than 2 minutes until the
circuits are stabilized after turning it on, then start
adjustment.
Procedure
1) Input
1
to PC on the adjustment menu screen.
2) Follow the instruction on PC display thereafter.
6-5 Adjustment (Camera Adjustment)
Input
C
to PC on the main menu screen to display the
adjustment menu screen and input to PC the appropriate
adjustment number. Pressing the Esc key on the adjustment
menu screen will restore the main menu screen.
***********************************************************
ELECTRIC VOLUME
***********************************************************
[1]
CDS SAMPLING PULSE
[ESC] RETURN TO MAIN MENU
Please select [1] or [ESC]
Electronic volume menu
Input 1.
Follow the instructions on
PC display thereafter.
Main menu
***********************************************************
MANUAL ADJUSTMENT PROGRAM
***********************************************************
[A]
DATA INITIALIZE
[B]
ELECTRIC VOLUME
[C]
ADJUSTMENT
[D]
AUTO FOCUS
[E]
SPOT NOISE
[ESC] END
Please select [A] - [E] or [ESC]
Input C.
***********************************************************
ADJUSTMENT
***********************************************************
[1]
AUTO IRIS CONTROL
[2]
WHITE BALANCE
[3]
CHROMA GAIN
[ESC] RETURN TO MAIN MENU
Please select [1] - [3] or [ESC]
Adjustment menu
Adjustment > Electronic Volume / Adjustment (Camera Adjustment)