background image

The following figure shows the type of optical connector that connects the storage

system Fibre Channel ports.

LC connector type

Connector type: LC duplex receptacle connector

Interval: 6.25 mm flat type, two rows

iSCSI cables

When constructing an iSCSI system with a direct connection or switch connection,

consider the following:

Data transfer

rate

Maximum length of cable

Multimode cable

Single mode

cable

OM2

OM3

OM4

10 Gbps (FCoE) 269.02 ft (82 m) 984.25 ft (300

m)

1804.46 ft (550

m)

Cable specifications for iSCSI optical interface

iSCSI cables

Appendix F: Data and power cables

Hitachi Virtual Storage Platform G200 Hardware Reference Guide

108

Summary of Contents for Virtual Storage Platform G200

Page 1: ...0 83 05 2x Hardware Reference Guide This document provides information about the system hardware components mechanical and environmental specifications for the Hitachi Virtual Storage Platform G200 storage system MK 94HM8020 13 April 2018 ...

Page 2: ... from authorized employees and other individuals and 2 Verifying that your data continues to be held retrieved deleted or otherwise processed in accordance with relevant laws Notice on Export Controls The technical data and technology inherent in this Document may be subject to U S export control laws including the U S Export Administration Act and its associated regulations and may be subject to ...

Page 3: ...lock configuration 12 VSP G200 model 12 Features 16 Scalability 17 Examples of supported VSP G200 configurations 17 Maximum number of mounted drive trays 18 Chapter 2 Virtual Storage Platform G200 controllers 21 CBSS controller 21 CBSS controller with front panel bezel 21 CBSS front panel LEDs without bezel 22 CBSS rear panel LEDs 23 CBSS CBSL AC power supply unit LEDs and connectors 25 CBSSD CBSL...

Page 4: ...Ds and connectors 39 Chapter 3 Drive trays 41 Small form factor drive tray DBS 41 SFF with front panel bezel 41 SFF front panel without bezel 42 SFF rear panel 43 SFF and LFF AC power supply unit LEDs and connectors 44 SFF power supply unit LEDs and connectors 45 Large form factor drive tray DBL 45 LFF with front panel bezel 46 LFF front panel without bezel 46 LFF rear panel 47 SFF and LFF AC powe...

Page 5: ...g the storage system 67 Powering off the storage system 67 Removing cables 68 Appendix A Mechanical specifications for VSP G200 69 VSP G200 mechanical specifications AC power supply model 69 VSP G200 mechanical specifications DC power supply model 77 Appendix B Electrical specifications for VSP G200 85 Electrical specifications 85 VSP G200 electrical specifications DC power supply 86 Appendix C En...

Page 6: ...wer cable model list 122 Appendix G Port address mapping 125 Port address mapping 125 Appendix H Third party racks 126 Third party rack support 126 Hitachi Universal V2 Rack rail kits 126 Hitachi Universal V2 Rack accessories 127 Third party rack support for DB60 dense intermix drive trays 127 Appendix I Power distribution units for Hitachi Universal V2 Rack 129 Americas single phase PDU 1P30A 8C1...

Page 7: ...3 3C19CE P 134 APAC and EMEA three phase PDU 3P16A 9C13 3C19CE P 135 APAC and EMEA three phase PDU 3P16A 15C13 3C19CE P 136 APAC and EMEA three phase PDU 3P32A 24C13 6C19CE P 137 Appendix J Regulatory compliance 139 Appendix K Safety and environmental notices 142 Index 144 Contents Hitachi Virtual Storage Platform G200 Hardware Reference Guide 7 ...

Page 8: ...ystem NEBS specifications The equipment with the NEBS specifications is suitable for use in Telecommunications Facilities The equipment with the NEBS specifications is suitable for use in the Common Bonding Network CBN Product version This document revision applies to the following product versions VSP G200 firmware 83 05 2x or later Hitachi Storage Virtualization Operating System SVOS 7 4 0 or la...

Page 9: ...pace Indicates text that is displayed on screen or entered by the user Example pairdisplay g oradb angle brackets Indicates variables in the following scenarios Variables are not clearly separated from the surrounding text or from other variables Example Status report name file version csv Variables in headings square brackets Indicates optional values Example a b indicates that you can choose a b...

Page 10: ...r storage capacity values Physical storage capacity values for example disk drive capacity are calculated based on the following values Physical capacity unit Value 1 kilobyte KB 1 000 103 bytes 1 megabyte MB 1 000 KB or 1 0002 bytes 1 gigabyte GB 1 000 MB or 1 0003 bytes 1 terabyte TB 1 000 GB or 1 0004 bytes 1 petabyte PB 1 000 TB or 1 0005 bytes 1 exabyte EB 1 000 PB or 1 0006 bytes Logical cap...

Page 11: ... technical support log on to Hitachi Vantara Support Connect for contact information https support hitachivantara com en_us contact us html Hitachi Vantara Community is a global online community for Hitachi Vantara customers partners independent software vendors employees and prospects It is the destination to get answers discover insights and make connections Join the conversation today Go to com...

Page 12: ...uring the fault tolerant integrity of the logical drives Self contained hardware based RAID logical drives provide maximum performance in compact external enclosures Essential hardware components are implemented with a redundant configuration so that the storage system can remain operational if a component fails Adding and replacing components along with firmware upgrades can be conducted while th...

Page 13: ...Channel 2 port 8 ports per system 32 16 Gbps Fibre Channel 4 port 16 ports per system Note Some controllers and drive trays are available with AC or DC power supplies see the following tables AC and DC controllers and drive trays are functionally identical except for power Controller Power supply Controller chassis Height Number of drives supported Supported drive type CBSS AC DW800 CBSS 2U 86 mm ...

Page 14: ...ns BNST DW F800 DBLD DC power supply DW F800 DBLC 3 5 inch LFF 12 2U 86 2 mm FMD tray DW F800 DBF 5 25 inch FMD 12 2U 86 2 mm Dense intermix drive tray DW F800 DB60 power supply contains BNST DW F800 DB60C 3 5 inch LFF 60 4U 174 3 mm Disk drives The VSP G200 storage system supports the listed disk drive capacities VSP G200 model Chapter 1 Hitachi Virtual Storage Platform G200 hardware overview Hit...

Page 15: ...B Flash module drives The VSP G200 storage system supports the listed flash module drive capacities Model number Drive type Drive capacity DKC F810I 1R6FN FMD DC2 1 75 TB 1 6 TiB DKC F810I 3R2FN FMD DC2 3 5 TB 3 2 TiB DKC F810I 6R4FN FMD DC2 7 TB 6 4 TiB DKC F810I 7R0FP FMD HD 7 TB DKC F810I 14RFP FMD HD 14 TB Solid state drives The VSP G200 storage system supports the listed SSD capacities Model ...

Page 16: ... other Storage Systems Maximum number of volumes per RAID group 2 048 Maximum number of DP pool volumes 2 048 Maximum number of DP pools 64 Maximum number of iSCSI hosts connected through a network switch Maximum number of iSCSI hosts connected through a network switch Maximum number of Fibre Channel devices connected through a Fibre Channel switch 255 Maximum storage system capacity physical capa...

Page 17: ...rted Maximum number of drives supported CBSS SFF drive tray 7 192 HDDs or SSDs LFF drive tray 7 108 HDDs or SSDs FMD drive tray 7 108 FMDs Dense intermix drive tray 4 264 HDDs or SSDs See the note about dense intermix drive restrictions Controller Drive tray Maximum number of drive trays supported Maximum number of drives supported CBSL SFF drive tray 7 180 HDDs or SSDs LFF drive tray 7 96 HDDs or...

Page 18: ...nclude drives installed in the controller SFF 7 192 HDDs or SSDs LFF 7 108 HDDs or SSDs FMD 7 108 FMDs Dense intermix drive tray 4 264 HDDs or SSDs1 Note 1The following SSD capacities 200 GB and 400 GB are supported in a dense intermix drive tray VSP G200 controller Drive trays Maximum number of trays Maximum number of drives CBSL Note The values below include drives installed in the controller SF...

Page 19: ...drives Dense intermix drive tray SFF drive dense intermix drive tray LFF drive dense intermix drive tray CBSL 7 0 180 96 5 1 192 132 3 2 204 168 1 3 216 204 0 4 252 252 VSP G200 controller Number of mounted drive trays Maximum 10 per path Maximum number of mounted drives SFF LFF drives Dense intermix drive tray SFF drive dense intermix drive tray LFF drive dense intermix drive tray CBSS CBSL 48 0 ...

Page 20: ...188 744 36 6 1224 792 33 7 1212 816 32 8 1248 864 29 9 1236 888 28 10 1272 936 25 11 1260 960 24 12 1296 1008 21 13 1284 1032 20 14 1320 1080 17 15 1308 1104 16 16 1344 1152 13 17 1332 1176 12 18 1368 1224 9 19 1356 1248 8 20 1392 1296 5 21 1380 1320 4 22 1416 1368 1 23 1404 1392 0 24 1440 1440 Maximum number of mounted drive trays Chapter 1 Hitachi Virtual Storage Platform G200 hardware overview ...

Page 21: ...dant data path through the other controller The controller is equipped with LED indicators for monitoring its operating conditions and notifying possible component replacement CBSS controller The CBSS controller includes specific functional LEDs located on the front and rear of controller and power supplies to provide its operating status CBSS controller with front panel bezel The following table ...

Page 22: ...t Us page at https support hds com en_us contact us html 5 POWER ON OFF main switch Powers the storage system 6 Lock Locks and unlocks the front panel bezel by using the supplied key Note Removing a controller can cause the POWER READY WARNING and ALARM LEDs on the front panel to turn off These LEDs return to their on state after the storage system recovers from the controller replacement CBSS fro...

Page 23: ...information messages SIM are issued 452xxx 462xxx 3077xx 4100xx and 410100 4 POWER ON OFF main switch Powers the storage system 5 Small form factor drives The twenty four 2 5 inch small form factor drives are positioned vertically The slots are organized from 0 to 23 CBSS rear panel LEDs The following table describes the definitions of the CBSS controller rear panel LEDs CBSS rear panel LEDs Chapt...

Page 24: ...en Power restoration in progress following power outage Fast blink green Restoring Slow blink green Restoring or sequential shutdown in progress 5 CTL WARN LED Amber blink one time Failure with fan 0 Amber blink two times Failure with fan 1 6 Cache flash memory N A 7 LAN RST switch Use only when instructed by customer support CBSS rear panel LEDs Chapter 2 Virtual Storage Platform G200 controllers...

Page 25: ...dule can be removed Blink red Backup module can be removed Blink red one time Battery failure Off battery is not installed failure occurred or firmware is being upgraded 13 SAS port N A 14 Port LED Blue Port link is established 15 Power supply unit N A CBSS CBSL AC power supply unit LEDs and connectors The following table describes the definitions of the CBSS and CBSL AC power supply unit LEDs and...

Page 26: ... DC power supply unit LEDs and connectors The following table describes the definitions of the CBSSD and CBSLD DC power supply unit LEDs and connectors Number Item Description 1 ALM RDY LED Red Power supply unit can be replaced Green Normal operation CBSSD CBSLD DC power supply unit LEDs and connectors Chapter 2 Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardwa...

Page 27: ...cription 1 POWER LED Green Storage system is powered on Amber Storage system is receiving power 2 READY LED Green Normal operation 3 WARNING LED Off Normal operation Amber Component requires maintenance Blink Failure requires maintenance Note When System Option Mode 1097 is set to ON the WARNING LED does not blink even if the following failure service information messages SIM are issued 452xxx 462...

Page 28: ... POWER READY WARNING and ALARM LEDs on the front panel to turn off These LEDs return to their on state after the storage system recovers from the controller replacement CBSL front panel without bezel The following table describes the definitions of the CBSL controller front panel LEDs Number Item Description 1 ACT LED Green Normal operation Blink green Drive is being accessed 2 ALM LED Red Drive s...

Page 29: ...ves The twelve 3 5 inch large form factor drives are positioned horizontally The slots are organized in the following order 8 9 10 11 4 5 6 7 0 1 2 3 CBSL rear panel The following table describes the definitions of the CBSL controller rear panel LEDs Number Item Description 1 Controllers Controller 1 left and Controller 2 right 2 Front end module N A 3 CTL ALM LED Red Controller can be removed CBS...

Page 30: ... with fan 1 6 Cache flash memory N A 7 LAN RST switch Use only when instructed by customer support 8 LAN port Maintenance LAN port left and user LAN port right 9 Uninterruptible power supply UPS port N A 10 ALARM LED for cache flash memory Red Cache flash memory can be removed 11 Backup module N A 12 STATUS Green Charging of the battery in the backup module is complete Blink green Battery in the b...

Page 31: ...C power supply unit LEDs and connectors The following table describes the definitions of the CBSS and CBSL AC power supply unit LEDs and connectors Number Item Description 1 Receptacle Connects to the power cable provided with the storage system 2 AC IN LED Blue AC input is normal 3 ALM RDY LED Red Power supply unit can be replaced CBSS CBSL AC power supply unit LEDs and connectors Chapter 2 Virtu...

Page 32: ...t Network and Drive Tray Ports and LEDs The controllers are equipped with specific interfaces for connecting powering configuring and managing the storage system The component LEDs display the operating status of the storage system Front end module descriptions The following front end modules are available for the controllers The LEDs display the operating status of the module CBSSD CBSLD DC power...

Page 33: ...D Red Small form factor pluggable can be removed Blue Normal link status Blink blue Front end module is in communication status 3 iSCSI connectors Connect to Ethernet cables 10 Gbps iSCSI board LEDs and connectors copper 10 Gbps iSCSI board LEDs and connectors optical Chapter 2 Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide 33 ...

Page 34: ...Gbps link Off No link connection 3 PORT LED Green Link connection is established Blinking Communication is in progress Off No link connection or not ready to communicate 4 iSCSI connectors Connect to Ethernet cables 10 Gbps iSCSI board LEDs and connectors copper Chapter 2 Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide 34 ...

Page 35: ...r pluggable can be removed Blue Normal link status at 8 Gbps Green Normal link status at 2 Gbps or 4 Gbps Table 2 32 Gbps 16 Gbps Fibre Channel Number Item Description 1 Fibre Channel connectors Connect to Fibre Channel cables 2 STATUS LED Green Front end module is in power on state Red Front end module can be removed safely 8 Gbps 16 Gbps or 32 Gbps Fibre Channel 4 port board LEDs and connectors ...

Page 36: ...re Channel Ports left to right Port 1 Port 2 Port 3 Port 4 CHB 1A 1A 3A 5A 7A CHB 1B 1B 3B 5B 7B CHB 1C 1C 3C 5C 7C CHB 1D 1D 3D 5D 7D CHB 1E 1E 3E 5E 7E CHB 1F 1F 3F 5F 7F CHB 1G 1G 3G 5G 7G CHB 1H 1H 3H 5H 7H CHB 2A 2A 4A 6A 8A CHB 2B 2B 4B 6B 8B CHB 2C 2C 4C 6C 8C CHB 2D 2D 4D 6D 8D CHB 2E 2E 4E 6E 8E CHB 2F 2F 4F 6F 8F CHB 2G 2G 4G 6G 8G 8 Gbps 16 Gbps or 32 Gbps Fibre Channel 4 port board LED...

Page 37: ...s in the power on state Red Front end module can be removed safely 2 PORT LED Red Small form factor pluggable can be removed Blue Normal link status at 16 Gbps Green Normal link status at 4 Gbps or 8 Gbps 3 Fibre Channel connectors Connect to Fibre Channel cables 16 Gbps Fibre Channel 2 port board LEDs and connectors Chapter 2 Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platf...

Page 38: ...D 3D CHB 1E 1E 3E CHB 1F 1F 3F CHB 1G 1G 3G CHB 1H 1H 3H CHB 2A 2A 4A CHB 2B 2B 4B CHB 2C 2C 4C CHB 2D 2D 4D CHB 2E 2E 4E CHB 2F 2F 4F CHB 2G 2G 4G CHB 2H 2H 4H 16 Gbps Fibre Channel 2 port board LEDs and connectors Chapter 2 Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide 38 ...

Page 39: ...tenance LAN port used by service personnel 5 LAN ALARM LED Red LAN blade can be removed 6 Uninterruptible power supply UPS port N A Back end module LEDs and connectors The back end module LEDs display the operating status of the module LAN blade LEDs and connectors Chapter 2 Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide 39 ...

Page 40: ...ATH 1 connector Connects to a drive tray 2 PORT LED Blue Normal link status Back end module LEDs and connectors Chapter 2 Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide 40 ...

Page 41: ...e across all host connection ports conventional hard disk drives HDD are not included or configurable with all flash arrays Small form factor drive tray DBS The following describes the physical specifications of the small form factor drive tray Name Model name Height Number of drive slots Drive type DBS DW F800 DBSC 2U 88 2 mm 24 2 5 inch SFF SFF with front panel bezel Number Item Description 1 PO...

Page 42: ... using the supplied key SFF front panel without bezel Number Item Description 1 ACT LED Green Normal operation Blink green Drive is being accessed 2 ALM LED Red Drive stopped due to a failure and can be replaced 3 POWER READY and LOCATE LEDs Green Drive tray is powered on SFF front panel without bezel Chapter 3 Drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide 42 ...

Page 43: ...inch small form factor drives are positioned vertically The slots are organized from 0 to 23 SFF rear panel Number Item Description 1 ENC N A 2 POWER LED Green ENC is in the power on state 3 LOCATE LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility SFF rear panel Chapter 3 Drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Gu...

Page 44: ...r cable provided with the storage system 12 AC IN LED Green Normal operation 13 ALM LED Red Power supply unit can be replaced 14 RDY LED Green Normal operation SFF and LFF AC power supply unit LEDs and connectors Both SFF and LFF drive trays are equipped with AC power supply units The AC power supply units include LEDs to display its operating status Number Item Description 1 RDY LED Green Normal ...

Page 45: ...Number Item Description 1 RDY LED Green Normal operation 2 DC IN LED Green DC input is operating normally 3 ALM LED Red Power supply unit can be replaced Large form factor drive tray DBL The following describes the physical specifications of the large form factor drive tray Name Model name Height Number of drive slots Drive type DBL DW F800 DBLC 2U 88 2 mm 12 3 5 inch LFF SFF power supply unit LED...

Page 46: ...on of the chassis Can be turned on or turned off by the maintenance utility 4 Lock Locks and unlocks the front panel bezel by using the supplied key LFF front panel without bezel Number Item Description 1 POWER READY and LOCATE LEDs Green Drive tray is powered on LFF with front panel bezel Chapter 3 Drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide 46 ...

Page 47: ...M LED Red Drive stopped due to a failure and can be replaced 4 Large form factor drives The twelve 3 5 inch large form factor drives are positioned horizontally The slots are organized in the following order 8 9 10 11 4 5 6 7 0 1 2 3 LFF rear panel Number Item Description 1 ENC N A 2 POWER LED Green ENC is in the power on state LFF rear panel Chapter 3 Drive trays Hitachi Virtual Storage Platform ...

Page 48: ...sole This port is reserved 10 Power supply unit N A 11 Receptacle Connects to the power cable provided with the storage system 12 AC IN LED Green Normal operation 13 ALM LED Red Power supply unit can be replaced 14 RDY LED Green Normal operation SFF and LFF AC power supply unit LEDs and connectors Both SFF and LFF drive trays are equipped with AC power supply units The AC power supply units includ...

Page 49: ... operating status Number Item Description 1 RDY LED Green Normal operation 2 DC IN LED Green DC input is operating normally 3 ALM LED Red Power supply unit can be replaced Flash module drive tray DBF The following describes the physical specifications of the flash module drive tray Name Model name Height Number of drive slots Drive type DBF DW F800 DBF 2U 87 mm 12 Flash module drive FMD SFF power ...

Page 50: ...ray is operational 3 LOCATE LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility 4 Lock Locks and unlocks the front panel bezel by using the supplied key FMD with front panel bezel Chapter 3 Drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide 50 ...

Page 51: ...ks for about two to five minutes until the startup processing is complete ALM LED Red Drive stopped due to a failure and can be replaced Note ACT indicator is only printed on some types of FMDs 3 POWER READY and LOCATE LEDs Green Drive tray is powered on Green Drive tray is operational FMD front panel without bezel Chapter 3 Drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guid...

Page 52: ...Slots are organized the following way 9 10 11 6 7 8 3 4 5 0 1 2 FMD rear panel Number Item Description 1 ENC N A 2 POWER LED Green ENC is in the power on state 3 LOCATE LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility FMD rear panel Chapter 3 Drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide 52 ...

Page 53: ...orage system 11 Three LEDS top to bottom RDY LED AC IN LED ALM REPLACE LED Green Power supply unit is operating normally Green Power supply unit is operating normally Red Power supply unit can be replaced High density intermix drive tray DB60 The following describes the physical specifications of the high density drive tray Name Model name Height Number of drive slots Drive type DB60 DW F800 DB60C...

Page 54: ...ray is operational 3 LOCATE LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility 4 Lock Locks and unlocks the front panel bezel by using the supplied key Dense intermix drive tray with front panel bezel Chapter 3 Drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide 54 ...

Page 55: ...nd can be replaced Note At the rear of the drive tray the drives are organized from left to right On the left side of the preceding figure the rear of the drive tray is at the top Rear of drive tray 48 59 36 47 24 35 12 23 Front of drive tray 00 11 Dense intermix drive tray display LEDs Chapter 3 Drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide 55 ...

Page 56: ...able provided with the storage system 6 ENC N A 7 PATH OUT LED Blue OUT side port is linked up 8 PATH OUT connector Connect to a drive tray 9 PATH IN LED Blue IN side port is linked up 10 PATH IN connector Connects to a controller or drive tray 11 Console This port is reserved 12 ALARM LED Red ENC can be replaced Dense intermix drive tray rear panel Chapter 3 Drive trays Hitachi Virtual Storage Pl...

Page 57: ...he location of the chassis Can be turned on or turned off by the maintenance utility 14 POWER LED Green ENC is in the power on state Dense intermix drive tray rear panel Chapter 3 Drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide 57 ...

Page 58: ...s iSCSI and FC cards For more information contact customer support Host port expansion chassis front panel bezel LEDs Number Item Description 1 POWER LED Green Host port expansion is turned on Amber PCIe module is turned on Off PCIe module is turned off 2 Safety lock Lock or unlock the front bezel PCIe switchboard Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware...

Page 59: ...is powered on Red PCIe switchboard can be replaced safely Off PCIe switchboard is powered off Host port expansion chassis fan Host port expansion chassis fan Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide 59 ...

Page 60: ...scription 1 ALM LED Red Fan failure has occurred Off Normal operation PCIe cable connector PCIe cable connector Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide 60 ...

Page 61: ...o link down and cables Cables can be removed safely Off Basic PCIe is normal or not set 4 Link Option LED Green Option PCIe Gen 3 0 8 Gbps is linked up normally Off Option PCIe is not linked up PCIe cable might not be connected If a cable is connected it can be removed safely 5 InAct Option LED Amber Option PCIe status changed from link up to link down and cables Cables can be removed safely Off O...

Page 62: ...pansion chassis power supply can be replaced safely Green Normal operation 2 AC IN LED Blue AC input is normal Host port expansion chassis power supply Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide 62 ...

Page 63: ... software application supplied by Hitachi Vantara For the latest interoperability updates and details see the SVP Service Processor OS and Hypervisor support for Gx00 Fx00 report at https support hitachivantara com en_us interoperability html Service processor hardware specifications The following table lists the hardware specifications for the service processor SVP provided by Hitachi Vantara Cau...

Page 64: ...ovides four RJ 45 ports Two ports connect to the storage system controllers one port for each controller One port connects to the IP network of the user One port connects to a user supplied management console PC Note This product is also designed for IT power distribution systems with phase to phase voltage Three of the four RJ 45 ports which connect to the controllers and the IP network are confi...

Page 65: ...tp 192 168 0 15 dev storage 8360004456789 emergency do Users are responsible for adopting the appropriate security procedures with the SVP including Applying Windows security patches Turning on automatic Windows updates or using the manual Windows update method Installing antivirus software that has been tested and approved by Hitachi SVP front panel The front panel of the physical SVP is equipped...

Page 66: ... with the SVP 2 Four LAN ports arranged as follows LAN3 LAN4 LAN1 LAN2 These ports connect to your IP network the management console PC and the user LAN port on each storage system controller Note After the Initial Startup Wizard is run the SVP can be used in non bridge mode In this mode the cables can be removed from SVP ports LAN3 and LAN4 and attached to switches For more information contact cu...

Page 67: ...blinking status 2 Release the main switch and the POWER LED returns to solid green after blinking for approximately three seconds The power off process begins The process takes approximately 18 minutes or longer depending on the amount of data that needs to be written The POWER LED is solid green during the powering off process The POWER LED changes from green to amber when the process is complete...

Page 68: ...ve the SAS cable 2 To remove an optical cable push the top of the connector of the optical cable 1 to release the latch and remove the SAS cable 2 To remove a LAN cable push the top of the LAN cable connector 1 to release the latch and remove the LAN cable 2 Removing cables Chapter 6 Maintaining the storage system Hitachi Virtual Storage Platform G200 Hardware Reference Guide 68 ...

Page 69: ...A SFF controller chassis consisting of controllers channel boards disk boards NAS module optional AC or DC power supplies and batteries with cooling fans 1 CBSL A LFF controller chassis consisting of controllers channel boards disk boards NAS module optional AC or DC power supplies and batteries with cooling fans Appendix A Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G2...

Page 70: ... power supplies or DC DC power supplies 1 FMD tray A drive tray that supports flash module drives and consists of an ENC and AC DC power supplies equipped with built in cooling fans 1 Dense intermix drive tray A drive chassis that supports a variety of drive types such as 2 5 inch drives 3 5 inch drives and flash drives The chassis consists of an ENC and AC DC power supplies equipped with built in...

Page 71: ...ray 3 5 type 393 85 1152 79 1729 29 2305 58 3916 14 5874 22 9790 36 GB FMD drive tray Flash module drive 1759 21 3518 43 7036 87 14073 74 GB Rotational speed min1 CBSS SFF drive tray 2 5 type 288 20 GB 15 000 RPM 2 5 type 576 39 GB 10 000 or 15 000 RPM 2 5 type 1152 79 GB 10 000 RPM 2 5 type 1729 29 GB 10 000 RPM 2 5 type 2305 58 GB 10 000 RPM CBSL LFF drive tray 3 5 type 1152 79 GB 10 000 RPM 3 5...

Page 72: ...f drives that can be mounted CBSS 24 drives CBSL 12 drives SFF drive tray 24 drives LFF drive tray 12 drives FMD drive tray 12 drives Dense intermix drive tray 60 drives Maximum number of spare drives 16 VSP G200 mechanical specifications AC power supply model Appendix A Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide 72 ...

Page 73: ...optical Copper iSCSI 10 Gbps copper iSCSI Number of ports 8 Gbps Fibre Channel optical 16 16 Gbps Fibre Channel optical 2 port 8 16 Gbps Fibre Channel optical 4 port 16 32 Gbps Fibre Channel optical 4 port 16 10 Gbps optical iSCSI 8 10 Gbps copper iSCSI 8 Transferred block size 512 bytes Maximum number of hosts using a Fibre Channel switch 255 Maximum number of hosts using a network switch 255 VSP...

Page 74: ...xpected host storage system hardware or software failure Therefore users are requested to back up all data Item Drive tray RAID Level SAS SAS 7 2k flash drives mounted RAID 1 2D 2D 4D 4D RAID 5 3D 1P 4D 1P 6D 1P 7D 1P RAID 6 6D 2P 12D 2P 14D 2P Item Specification Maximum number of parity groups 88 Maximum volume size 3 TB or 4 TB when using the LDEVs of other storage systems Maximum volumes host g...

Page 75: ... 32 x 3 5 inches 483 x 813 x 88 mm SFF drive tray WxDxH 19 x 22 2 x 3 5 inches 483 x 565 x 88 2 mm LFF drive tray WxDxH 19 x 22 2 x 3 5 inches 483 x 565 x 88 2 mm FMD drive tray WxDxH 19 x 30 x 3 4 inches 483 x 762 x 87 mm Dense intermix drive tray WxDxH 19 x 40 5 x 7 inches 482 x 1029 x 176 mm Mass approximate 2 CBSS 97 lbs 44 kg CBSL 101 4 lbs 46 kg SFF drive tray 51 lbs 23 kg LFF drive tray 59 ...

Page 76: ... specifications Item Specifications Capacity GB 64 GB Control method Read LRU Write after Battery backup Provided Backup duration Unrestricted saving to a nonvolatile memory Data in the cache memory is preserved against power failures If a power outage occurs data in cache memory is written to drives When the storage system enters Cache Backup mode the amber WARNING LED goes on to when the system ...

Page 77: ... withstand voltage AC 1 500 V 100 mA 1 min Insulation resistance DC 500 V 10 M Ω or more VSP G200 mechanical specifications DC power supply model Controllers Quantity Component Description 1 CBSSD A SFF controller chassis consisting of controllers channel boards disk boards NAS module optional DC power supplies and batteries with cooling fans 1 CBSLD A LFF controller chassis consisting of controll...

Page 78: ...oling fans and DC DC power supplies 1 LFF drive tray DBLD A drive tray that supports 3 5 inch disk drives and 3 5 inch flash drives The drive tray consists of an ENC cooling fans and DC DC power supplies VSP G200 mechanical specifications DC power supply model Appendix A Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide 78 ...

Page 79: ...in1 CBSSD SFF drive tray 2 5 type 288 20 GB 15 000 RPM 2 5 type 576 39 GB 10 000 or 15 000 RPM 2 5 type 1152 79 GB 10 000 RPM 2 5 type 1729 29 GB 10 000 RPM 2 5 type 2305 58 GB 10 000 RPM CBSLD LFF dense intermix drive tray 3 5 type 1152 79 GB 10 000 RPM 3 5 type 1729 29 GB 10 000 RPM 3 5 type 2305 58 GB 10 000 RPM Only available for DB60 DB60C 3 5 type 3916 14 GB 7 200 RPM 3 5 type 5874 22 GB 7 2...

Page 80: ...take temperature CBSS CBSL Up to 75 2º F 24º C 5 years 5 years Up to 86º F 30º C 5 years 4 years Up to 93 2º 34º C 4 years 3 years Up to 104º 40º C 3 years 2 years VSP G200 mechanical specifications DC power supply model Appendix A Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide 80 ...

Page 81: ...port 16 10 Gbps optical iSCSI 8 10 Gbps copper iSCSI 8 Transferred block size 512 bytes Maximum number of hosts using a Fibre Channel switch 255 Maximum number of hosts using a network switch 255 RAID specifications D Data drive P Parity drive Although the storage system with a configuration of RAID 1 RAID 5 or RAID 6 provides data reliability enhanced by redundancy there is a chance that user dat...

Page 82: ...rgets 2 048 Maximum volumes parity groups 2 048 Internal logic specifications Item Component Specifications Shared memory Flash memory 32 MB L3 cache memory 4 MB SDRAM 1 GB Data assurance method Data bus Parity Cache memory ECC 1 bit for correction 2 bits for detection Drive Data assurance code VSP G200 mechanical specifications DC power supply model Appendix A Mechanical specifications for VSP G2...

Page 83: ...tray 2 Notes 1 The startup time might be longer in proportion to the number of drive trays connected With a maximum configuration of 1 controller and 19 drive trays startup time is approximately 8 minutes 2 Value of maximum configuration when all controllers and drives are mounted 3 Mixing DBSD and DBLD drive trays might affect the maximum number of drives that can be mounted 4 If a drive is inser...

Page 84: ...ged the warning indication disappears and the storage system continues the operation in the Write Cache function The warning indication disappears within six hours Even when the warning is shown normal operation is assured in Write Through Read and write performance is lowered because the Write Cache function is disabled If the storage system is not charged for more than six months the battery can...

Page 85: ... 2 0x2 CBSL 4 0x2 2 0x2 SFF drive tray 2 4x2 1 2x2 LFF drive tray 1 9x2 1 0x2 FMD drive tray 2 6x2 1 3x2 Dense intermix drive tray 3 0x2 Current rating of breaker fuse A 16 0 each electrical Heat value normal kJ h CBSS 1800 or less CBSL 1550 or less SFF drive tray 1120 or less LFF drive tray 940 or less FMD drive tray 1300 1520 or less Dense intermix drive tray 3460 or less Steady state power VA W...

Page 86: ...e power supply facility so that the current carrying capacity for one power unit can provide the total capacity for two power units 3 This table shows the power requirement 100 V or 200 V for the maximum configuration The actual required power might exceed the value shown in the table when the tolerance is included VSP G200 electrical specifications DC power supply Input power specifications Item ...

Page 87: ...erminal Connector Positronic Industries Inc PCS Series Heat value kJ h 1800 1550 1120 940 Steady state power W 760 760 460 350 Power consumption W 500 430 310 260 Input current A 15 9 15 9 9 6 7 3 UPS No connection Remote adapter No connection VSP G200 electrical specifications DC power supply Appendix B Electrical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Referenc...

Page 88: ...tate Controller SFF LFF drive trays Dense intermix drive tray Operating 50 F to 104 F 10 C to 40 C 50 F to 104 F 10 C to 40 C 50 F to 95 F 10 C to 35 C Non operating 14 F to 122 F 10 C to 50 C 14 F to 122 F 10 C to 50 C 14 F to 122 F 10 C to 50 C Transport storage 22 F to 140 F 30 C to 60 C 22 F to 140 F 30 C to 60 C 22 F to 140 F 30 C to 60 C Temperature change rate C h 10 or less State Controlle...

Page 89: ...ss Humidity State Percentage Operating 8 to 80 Non operating 8 to 90 Transport storage 5 to 95 Maximum wet bulb temperature C 29 non condensing Vibration State m s2 Operating 2 5 or less Within 5 seconds resonance point 10 Hz or less Non operating 5 0 or less at 5 Hz to 300 Hz no damage to product 9 8 1 0 G Within 5 seconds resonance point 10 Hz or less Transport packed 5 0 or less Environmental s...

Page 90: ...onmental temperature 10 C to 35 C when DKC F710I 1R6FM or DKC F710I 3R2FM drive is installed Operating m 3 000 Environmental temperature 10 C to 32 C 900 Environmental temperature 10 C to 40 C 3 000 Environmental temperature 10 C to 32 C OR 900 Environmental temperature 10 C to 40 C when DKC F810I 1R6FN 3R2FN 6R4FN 7R0FP 14RFP drive is installed Non operating m 60 to 12 000 N A Environmental speci...

Page 91: ... 40 C Non operating m N A Atmosphere Avoid areas exposed to corrosive gas and salty air Acoustic Noise State Controller SFF LFF Dense intermix drive tray Opera ting 60 dB Environmental temperature 32 C or less 1 60 dB Environmen tal temperature 32 C or less 1 71 dB Environmental temperature 32 C or less 1 2 3 4 Non opera ting 55 dB 55 dB 71 dB Environmental temperature 32 C or less 1 2 3 4 Environ...

Page 92: ...ironmental temperature 32 C or less 1 2 3 When accessing the dense intermix drive tray do not work for long times at the rear of the rack Non opera ting 55 dB Environmental temperature 32 C or less 1 2 3 4 55 dB Notes 1 The system s internal temperature controls the rotating speed of the fan module Therefore this standard value might be exceeded if the maximum load continues under high temperature...

Page 93: ...o critical damage for product 9 8 1 0 G Adopt fall prevention safety measures Transport packed m s2 5 0 or less Impact Operating m s2 20 or less 10 ms half sine wave Non operating m s2 50 or less Transport packed m s2 80 or less Angle at which the storage system turns over 15 or less To be measured when installed on leveling bolts Altitude Operating m 60 to 1 800 above sea level Environmental temp...

Page 94: ... temperature controls the rotating speed of the fan Therefore this standard value might be exceeded if the maximum load continues under high temperature environment or if a system failure occurs Measured at the position 1 5 meter away from the storage system at a height of 1 5 meters Standby 55 dB VSP G200 environmental specifications DC power supply Appendix C Environmental specifications for VSP...

Page 95: ...ndards IEEE 802 1D STP IEEE 802 1w RSTP IEEE 802 3 CSMA CD IEEE 802 3u Fast Ethernet IEEE 802 3z 1000 BASE X IEEE 802 1Q Virtual LANs IEEE 802 3ae 10 Gigabit Ethernet RFC 768 UDP RFC 783 TFTP RFC 791 IP RFC 793 TCP RFC 1157 SNMP v1 RFC 1231 MIB II RFC 1757 RMON RFC 1901 SNMPv2 iSCSI specifications Item Specification Comments iSCSI target function Supported N A iSCSI target function Supported TrueC...

Page 96: ...ptical OM3 OM2 MMF cable N A Network switch L2 or L3 switch Should comply with IEEE802 3ae Switch cascading Maximum 5 switches or fewer Minimum number of cascading switches is recommended MAC address Per port fixed value Factory setting World Wide Unique value Cannot be changed Maximum transfer unit MTU 1 500 4 500 9 000 bytes Ethernet frame Jumbo frame MTU size greater than 1500 Link aggregation ...

Page 97: ...lt an iSCSI connection might be delayed When an iSCSI Port IPv6 is set to Enabled verify the IPv6 router is connected to the same network and then set IPv6 global address automatically Subnet mask Supported N A Gateway address Supported N A DHCP N A N A DNS N A N A Ping ICMP ECHO Transmit Receive Supported N A IPsec2 N A N A TCP port number 3260 Changeable among 1 to 65 535 Observe the iSCSI speci...

Page 98: ...rror recovery by retrying from host Does not support Level 1 and Level 2 Header digest Supported Detects header error or data error with iSCSI communication The storage system follows the host s digest setting If digest is enabled the performance degrades The amount of the degradation depends on factors such as host performance of host and transaction pattern Data digest Supported Maximum iSCSI co...

Page 99: ...7 operating systems 2 IP Security Authentication and encryption of IP packets The storage system does not support IPsec 3 iqn iSCSI Qualified Name The iqn consists of a type identifier iqn a date of domain acquisition a domain name and a character string given by the individual who acquired the domain Example iqn 1994 04 jp co hitachi rsd d7m t 10020 1b000 tar 4 eui 64 bit Extended Unique Identifi...

Page 100: ...mbient temperature is 86 F 30 C or less on average Periodic parts replacement is required For customers with maintenance service contracts parts are replaced periodically in keeping with the terms of the contract Note The battery protects the data in the cache memory in an emergency such as a sudden power failure In these cases follow the normal power down procedure If not the battery might reach ...

Page 101: ...or storage system installation vary according to the specific storage system and network configuration Fibre Channel and iSCSI cables are used to connect the controllers to a customer switch or host Serial Attached SCSI SAS cables are used to connect drive trays to controllers and other drive trays Appendix F Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide 101 ...

Page 102: ... each controller to a host computer direct connection or to several host computers via an Ethernet switch SAS SAS optical Connects the controller to a drive tray or a drive tray to another drive tray Two SAS cables are provided with each drive tray SAS cables are also used to connect NAS modules to switches Ethernet RJ 45 Four shielded Category 5e or 6a Ethernet cables are required for connecting ...

Page 103: ...bps 492 1 feet 150 meters 8 Gbps 164 feet 50 meters 16 Gbps 115 feet 35 meters 62 5 micron 2 Gbps 328 1 feet 100 meters 4 Gbps 230 feet 70 meters 8 Gbps 69 feet 21 meters Required cables Appendix F Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide 103 ...

Page 104: ...AL Available Available Available Available default P to P Available Available Available Available Fabric Available Available Available Available For the 16 Gbps Fibre Channel ports and for 16 Gbps SFP added to the 4 port FC 32 Gbps package the combinations between data transfer speeds and connection types are as follows Connecti on type Data transfer speeds for 16 Gbps ports SFPs 2 Gbps 4 Gbps 8 G...

Page 105: ... available No available Available Available Available Available default2 Fabric Available Available Available Available Available Available Notes 1 If this combination is specified the maximum transfer speed automatically specified is 8 Gbps 2 If this default value is set Fabric is set to ON automatically Note The five Hitachi FC HBAs also have an alternate option of Fabric Emulation When the HBA ...

Page 106: ...t 10 km 4 Gbps 493 ft 150 m 1246 72 ft 380 m 1312 3 ft 400 m 8 Gbps 164 04 ft 50 m 493 ft 150 m 623 36 ft 190 m 16 Gbps 114 8 ft 35 m 328 08 ft 100 m 410 1 ft 125 m 32 Gbps 65 62 ft 20 m 229 7 ft 70 m 328 08 ft 100 m Fibre Channel cables Appendix F Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide 106 ...

Page 107: ...lent to DXLC 2P PC xxM GC50 125 2SR OMx 50 125 μm 62 5 125 μm Multimode Wavelength 850 nm LC connector LC connector LC LC cable longwave DXLC 2PS SPC xxM SMC 10 125 2SR 9 125 μm Singlemode Wavelength 1300 nm The following figure shows the connector used for optical interfaces Fibre Channel cables Appendix F Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide 107 ...

Page 108: ...bles When constructing an iSCSI system with a direct connection or switch connection consider the following Data transfer rate Maximum length of cable Multimode cable Single mode cable OM2 OM3 OM4 10 Gbps FCoE 269 02 ft 82 m 984 25 ft 300 m 1804 46 ft 550 m Cable specifications for iSCSI optical interface iSCSI cables Appendix F Data and power cables Hitachi Virtual Storage Platform G200 Hardware ...

Page 109: ...ure shows the connector used for optical interfaces The following figure shows the type of optical connector that connects the storage system optical iSCSI ports LC connector type Connector type LC duplex receptacle connector Interval 6 25 mm flat type two rows Cable specifications for 10 Gbps iSCSI copper interface iSCSI cables Appendix F Data and power cables Hitachi Virtual Storage Platform G20...

Page 110: ...bps 1000BASE T STP use an STP cable that suppresses radio noise RJ 45 Category 6a LAN cable 50 m 10 Gbps 10GBASE T STP use an STP cable that suppresses radio noise RJ 45 The following figure shows a 10 Gbps iSCSI cable iSCSI cables Appendix F Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide 110 ...

Page 111: ...RFC 1231 MIB II RFC 1757 RMON RFC 1901 SNMPv2 iSCSI specifications Item Specification Comments iSCSI target function Supported N A iSCSI target function Supported TrueCopy only iSCSI ports 2 per interface board VSP Gx00 models Maximum 32 per iSCSI system Connection methods Direct and switch connections Host connections 255 maximum per iSCSI port With Linux software initiator the maximum number dec...

Page 112: ... aggregation Not supported N A Tagged VLAN Supported N A IPv4 Supported N A IPv6 Supported Note the following precautions When iSCSI Port IPv6 is set to Enabled if the IPv6 global address is set to automatic the address is determined by acquiring a prefix from an IPv6 router If the IPv6 router does not exist in the network the address cannot be determined As a result an iSCSI connection might be d...

Page 113: ...e network equipment preventing the storage system from communicating through the new port number iSCSI name Both iqn3 and eui4 types are supported The unique iqn value is automatically set when a target is made iSCSI name is configurable Error recovery level 0 zero Error recovery by retrying from host Does not support Level 1 and Level 2 Header digest Supported Detects header error or data error w...

Page 114: ...and Dynamic Link Manager Pass switching is achieved Not supported on Windows Vista and Windows 7 operating systems 2 IP Security Authentication and encryption of IP packets The storage system does not support IPsec 3 iqn iSCSI Qualified Name The iqn consists of a type identifier iqn a date of domain acquisition a domain name and a character string given by the individual who acquired the domain Ex...

Page 115: ...have hard edges and which you can remove without cutting Never bundle network cables with power cables If network and power cables are not bundled separately electromagnetic interference EMI can affect your data stream If you run cables from overhead supports or from below a raised floor include vertical distances when calculating necessary cable lengths If you use overhead cable supports Verify t...

Page 116: ...ower cable can have a serious impact on the operation of an enterprise storage system Unlike data cables power connectors do not have built in retention mechanisms to prevent this from happening To prevent accidental unplugging or unseating of power cables the storage system includes a rubber cable retention strap near the AC receptacle on each controller These straps shown in the following image ...

Page 117: ...c standard Common standards are the IEC C13 receptacle for loads up to 10 amperes A and the IEC C19 receptacle for loads up to 15 A Number Country or region Voltage rating VAC Current rating amperes Plug type 11 North America 100 127 15 NEMA 5 15P Brazil 200 240 10 20 NEMA 5 15P Japan 100 127 12 JIS C8303 Taiwan 100 127 12 16 CNS 690 2 North America 100 127 20 NEMA 5 20P 3 North America 200 240 20...

Page 118: ...so Malaysia and Ireland 4 Also known as Schuko connector and used in Austria Belgium Finland France Germany Greece Hungary Indonesia Netherlands Norway Poland Portugal Russia Spain and Sweden 5 Supersedes type BS 546 6 3 wire two phase and earth Physical variations connector size and color indicate amperage rating Used in Switzerland for a true 16 A application 7 4 wire three phase and earth Physi...

Page 119: ... 11 2 NEMA 5 15P 3 IEC 83 NEMA L6 20P 200V 240V 1 ANSI C73 11 2 NEMA 6 15P 3 IEC 83 CEE 7 7 200V 240V 4 CEE 7 II IV VII 3 IEC 83 BS 1363 200V 240V 5 BS 1365 3 IEC 83 AS 3112 200V 240V 6 AS C112 AC connections Appendix F Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide 119 ...

Page 120: ...lity Type of AC source wall outlet or modular and monitored PDU to be used Serviceability of components to be connected Storage systems require a country specific power cable for direct connection to a facility AC feed Storage systems are designed to allow replacement of hot pluggable components without removing the chassis from the rack As a result power cables can be short because cable movement...

Page 121: ...le management Rack installations should be planned for operational efficiency ease of maintenance and safety Hitachi offers the Backend Configuration Utility BECK a graphical cable management application that can relieve the typical cable congestion created when populating a rack with storage systems and their accessories Cable retention Unintentional unplugging or unseating of a power cable can h...

Page 122: ...m 2 pole power cable with grounding terminal AC 250 V 13 A or 15 A A F6516 P620 Power cable for PDU 1 A F6516 P630 Power cable for PDU 1 Table 4 SAS cables Model number Specification DW F800 SCQ1 1 m SAS cable including omega clip 2 DW F800 SCQ1F 1 5 m SAS cable including omega clips 2 DW F800 SCQ3 3 m SAS cable including omega clips 2 DW F800 SCQ5 5 m SAS cable including omega clips 2 DW F800 SCQ...

Page 123: ... LC optical cable for optical A 6515 HM10L 10 m LC LC optical cable for optical A 6515 HM20L 20 m LC LC optical cable for optical A 6515 HM30L 30 m LC LC optical cable for optical A 6515 HM50L 50 m LC LC optical cable for optical A 6515 HM100L 100 m LC LC optical cable for optical A 6515 HM200L 200 m LC LC optical cable for optical A 6515 HM300L 300 m LC LC optical cable for optical A 6515 JM5L 5 ...

Page 124: ...l number Specification A 6515 JM300L 300 m LC LC optical cable for optical Data and power cable model list Appendix F Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide 124 ...

Page 125: ... might not be able to recognize the VOL If this problem or other problems occur revert to the default value of EF EF CD B2 98 72 55 3A 25 E8 CC B1 67 7 64 39 23 E4 CB AE 90 6E 53 36 1F E2 CA AD 8F 6D 52 35 1E E1 C9 AC 88 6C 51 34 1D E0 C7 AB 84 6B 4E 33 1B DC C6 AA 82 6A 4D 32 18 DA C5 A9 81 69 4C 31 17 D9 C3 A7 80 67 4B 2E 10 D6 BC A6 7C 66 4A 2D 0F D5 BA A5 7A 65 49 2C 08 D4 B9 A3 79 63 47 2B 04...

Page 126: ...ward each other The area behind the storage system and between the vertical 19 inch mounting posts must be free of PDUs and cable loops Hitachi Universal V2 Rack rail kits Use rail kits to mount the Hitachi Virtual Storage Platform family storage system in a Hitachi Universal V2 Rack The following tables list the rail kit information for the specified storage systems Table 6 Rail kits for VSP Gx00...

Page 127: ...e size and weight of the DB60 dense intermix drive trays used with VSP Gx00 models pay close special attention when mounted in third party racks When mounting DB60 dense intermix drive trays in third party racks observe the following guidelines and see the following figure Use anti tilt floor plates or ceiling mounted fixing brackets to stabilize the rack Use a rack that is at least 40 94 in 1040 ...

Page 128: ...Third party rack support for DB60 dense intermix drive trays Appendix H Third party racks Hitachi Virtual Storage Platform G200 Hardware Reference Guide 128 ...

Page 129: ...able current load on each PDU before plugging the device into the PDU Balance the electrical current load between available PDUs Americas single phase PDU 1P30A 8C13 3C19UL P The following figure and table describes the specifications of the PDU Figure 1 Americas PDU for the Hitachi Universal V2 Rack Single phase PDU 1P30A 8C13 3C19UL P Part Number Region Phase Description 1P30A 8C13 3C19U L P Ame...

Page 130: ...ption 1P30A 15C13 3C19 UL P Americas Single 208V 30A 24A rated 60Hz 15 IEC C13 3 IEC C19 sockets NEMA L6 30P input power plug 4 5 m 14 76 feet cable Americas three phase PDU 3P30A 8C13 3C19UL P The following figure and table describes the specifications of the PDU Americas single phase PDU 1P30A 15C13 3C19UL P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storag...

Page 131: ...ted 60Hz 8 IEC C13 3 IEC C19 sockets NEMA L15 30P input power plug 4 5 m 14 76 feet cable Americas three phase PDU 3P30A 15C13 3C19UL P The following figure and table describes the specifications of the PDU Americas three phase PDU 3P30A 15C13 3C19UL P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G200 Hardware Reference Guide 131 ...

Page 132: ...ted 60Hz 15 IEC C13 3 IEC C19 sockets NEMA L15 30P input power plug 4 5 m 14 76 feet cable Americas three phase PDU 3P30A 24C13 6C19UL P The following figure and table describes the specifications of the PDU Americas three phase PDU 3P30A 24C13 6C19UL P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G200 Hardware Reference Guide 132 ...

Page 133: ...0Hz 24 IEC C13 6 IEC C19 sockets NEMA L15 30P input power plug 4 5 m 14 76 feet cable APAC and EMEA single phase PDU 1P32A 9C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA single phase PDU 1P32A 9C13 3C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G200 Hardware Reference Guide 133 ...

Page 134: ...Hz 9 IEC C13 3 IEC C19 sockets IEC309 Blue 2P E input power plug 4 5 m 14 76 feet cable APAC and EMEA single phase PDU 1P32A 18C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA single phase PDU 1P32A 18C13 3C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G200 Hardware Reference Guide 134 ...

Page 135: ...60Hz 18 IEC C13 3 IEC C19 sockets IEC309 Blue 2P E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P16A 9C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA three phase PDU 3P16A 9C13 3C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G200 Hardware Reference Guide 135 ...

Page 136: ...0Hz 9 IEC C13 3 IEC C19 sockets IEC309 Red 3P N E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P16A 15C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA three phase PDU 3P16A 15C13 3C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G200 Hardware Reference Guide 136 ...

Page 137: ...0Hz 15 IEC C13 3 IEC C19 sockets IEC309 Red 3P N E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P32A 24C13 6C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA three phase PDU 3P32A 24C13 6C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G200 Hardware Reference Guide 137 ...

Page 138: ...32A 24C13 6C19 CE P APAC and EMEA Three 400V max 3x 32A 50Hz 60Hz 24 IEC C13 6 IEC C19 sockets IEC309 Red 3P N E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P32A 24C13 6C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G200 Hardware Reference Guide 138 ...

Page 139: ... Regulatory compliance This equipment has been tested and certified for compliance with the following standards Appendix J Regulatory compliance Hitachi Virtual Storage Platform G200 Hardware Reference Guide 139 ...

Page 140: ...N22 KC Korea KN24 KC Korea Electronic emission certifications EN5522 2010 CE EU EN5524 2010 CE EU EN61000 3 2 2006 A1 A2 CE EU EN61000 3 3 2008 CE EU Safety certifications UL and CSA 60950 1 2007 cTUVus USA and Canada EN60950 1 2006 A1 TUV Germany IEC60950 1 2005 A 1 N A All CB countries IEC60950 1 2005 A 1 S Mark Argentina TP TC 004 2011 EAC Russia CNS 14336 1 BSMI Taiwan EN60950 1 2006 A1 CE EU ...

Page 141: ... Processing Standards FIPS 2694 FIPS 140 2 Level 1 Consolidated Validation Certificate http csrc nist gov groups STM cmvp documents 140 1 140val all htm USA and Canada Encryption back end module provides high speed data at rest encryption Appendix J Regulatory compliance Hitachi Virtual Storage Platform G200 Hardware Reference Guide 141 ...

Page 142: ...lectrical and electronic equipment should be disposed at the end of life separately from your household wastes There are separate collection systems for recycling in the European Union For more information contact the local authority or the dealer where you purchased the product Recycling A nickel metal hydride battery is used in the Cache Backup Battery A nickel metal hydride battery is a resourc...

Page 143: ...DVISED OF THE POSSIBILITY OF SUCH DAMAGE FDA radiation regulation The array complies with FDA radiation performance standard 21 CFR subchapter J EMI regulation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment ...

Page 144: ...power 116 Fibre Channel 104 iSCSI 108 managing 114 cables continued removing 68 required 101 retention 116 121 CBSL controller AC power supply unit 25 31 CBSL controller 27 front panel bezel 27 rear panel 29 without front panel bezel 28 CBSLD power supply unit 26 32 CBSS controller AC power supply unit 25 31 rear panel 23 with front panel bezel 21 without front panel bezel 22 CBSSD power supply un...

Page 145: ...35 8 Gbps Fibre Channel board 35 front panel bezels CBSL controller 27 CBSS controller 21 dense intermix drive tray 54 front panel bezels continued flash module drive tray 50 host port expansion chassis 58 large form factor drive tray 46 small form factor drive tray 41 H hardware specifications 63 Hitachi Virtual Storage Platform G200 12 host 32 63 host port expansion 58 host port expansion chassi...

Page 146: ...S controller 23 dense intermix drive tray 56 flash module drive tray 52 large form factor drive tray 47 small form factor drive tray 43 regulatory compliance 139 removing cables 68 replacement parts battery unit 100 required cables 101 retention cables 116 121 S SAS cables removing 68 scalability 17 server 63 service processor 63 64 side panels 127 small form factor drive tray AC power supply unit...

Page 147: ...d configurations 17 SVP hardware specifications 63 T third party rack DB60 dense intermix drive tray 127 third party racks 126 third party racksmounting guidelines 126 Index Hitachi Virtual Storage Platform G200 Hardware Reference Guide 147 ...

Page 148: ...050 2639 USA www HitachiVantara com community HitachiVantara com Regional Contact Information Americas 1 866 374 5822 or info hitachivantara com Europe Middle East and Africa 44 0 1753 618000 or info emea hitachivantara com Asia Pacific 852 3189 7900 or info marketing apac hitachivantara com ...

Reviews: