4.
To turn on the storage system, click
Power Management > Power on
Storage System
. At the confirmation message, click
Submit
.
5.
To turn off the storage system, click
Power Management > Power off
Storage System
. At the confirmation message, click
Submit
.
Using LEDs to diagnose problems
The storage system LEDs provide system status and diagnostic indicators.
If the storage system used in a remote TrueCopy configuration restarts with
the TrueCopy status of
enabled
, the following occur:
• The path used by TrueCopy becomes blocked. Notifications from the
Hitachi Device Manager - Storage Navigator email alert function, SNMP
Agent Support function, and SNMP trap occur when the path is blocked.
Follow the instructions in the notification. The blocked path recovers
automatically after restarting the storage system.
• If the TrueCopy pair status is
PAIR
or
COPY
, the pair changes to
PSUE
. In
this case, suspend the pairs before restarting the storage system.
Power LED does not go on
Procedure
1.
Set the main switch to on.
2.
Is the Power LED on at the controller?
• Yes: Go to step 9.
• No: Power on the host computer.
3.
Is the Power LED on at the controller?
• Yes: Go to step 9.
• No: Set the main switch to off.
4.
Check that the PDU on the rack is delivering power to the storage
system.
5.
Verify that the AC cable is correctly connected to the plug socket and the
equipment.
6.
Set the main switch to on.
7.
Is the Power LED on at the controller?
• Yes: Go to step 9.
• No: Set the main switch to off.
8.
Contact your administrator. Go to step 10.
9.
Is the Ready LED on?
• Yes: Continue to use the equipment, even if the green Ready LED
blinks fast.
• No: Use the following corrective action. See
or Ready LED went on and then off on page 390
.
Troubleshooting the storage system
389
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...