L42S504
9
2. Switch the Ca210 to xyLv-mode (with press “MODE” button)
3. Switch the Ca210 channel to Channel 05 (with up or down “MEMORY CH” button)
4. The LCD-indicator on Ca210 will show x =272, y =278, Lv can adjust to max luminance.
5. Use the item R Offset and B Offset adjust to Adjust black balance: use 20 IRE(Pattern 190) signal, and adjust the
black balance, until the Ca210 show x =272, y =278.
6. Use the item R Gain and B Gain to adjust white balance: use 100 IRE (Pattern 105) signal, and adjust the white
balance, until the Ca210 show x =272, y =278.
7. Adjust item “ZR-Contrast” to check color temperature is saturation or not: Add by 7 steps and then to adjust the
item R Gain and item B Gain to check the color temperature is saturation or not, until is saturation.
8. Enter the item “Color Temp” to select another color temperature to adjust.
B. Adjust Normal temperature:
1. Set the pattern generator to pattern 104 or 0 IRE pattern. Adjust the Item “ZR-Bright” value and can adjust to min
luminance
2. Switch the Ca210 to T
△
uvLv-mode (with press “MODE” button)
3. Switch the Ca210 channel to Channel 05 (with up or down “MEMORY CH” button)
4. The LCD-indicator on Ca210 will show T=9300K.
5. Adjust the Color Temp item: Normal, until Ca210 indicator reached the value T=9300k.
C. Adjust Warm color-temperature:
1. Set the pattern generator to pattern 104 or 0 IRE pattern. Adjust the Item “ZR-Bright” value and can adjust to min
luminance
2. Switch the Ca210 to T
△
uvLv-mode (with press “MODE” button)
3. Switch the Ca210 channel to Channel 05 (with up or down “MEMORY CH” button)
4. The LCD-indicator on Ca210 will show T=6500K.
5. Adjust the Color Temp item: Warm, until Ca210 indicator reached the value T=6500k.
Press “Exit” button on remote control to quit from factory mode.
NOTE 1:
If you choose to do EEPROM Initialization (EEPROM Init), you MUST
write down
all White Balance values
before
doing so. These values will be reset to a default value.
All white balance factory adjustments will be LOST. It can be done as a NOTE anywhere in same page, please.
NOTE 2:
Activating Reset to Default Settings (Reset to Def) will zero BOTH hour counters, the one for back light time and the
one for Total time.
You may want to add a condition or event in which this would be recommended.
Summary of Contents for ULTRAVISION L42S504
Page 4: ...L42S504 4 Dimensions ...
Page 15: ...L42S504 15 Power Board ...
Page 33: ...L42S504 33 PCB Layout Main Board 756TQACBZK01502 ...
Page 34: ...L42S504 34 ...
Page 35: ...L42S504 35 Power Board 715G3196 1B ...
Page 36: ...L42S504 36 ...
Page 37: ...L42S504 37 ...
Page 38: ...L42S504 38 Key Board 715G3293 1 IR Board 715G3482 1 ...
Page 66: ...L42S504 66 U01 056T62740 IR KSM 2003TH2M 37 9KHZ ...
Page 67: ...L42S504 67 Accessories M4x12 0M1G9401247CR3 M4x12 0M1G9401247CR3 Part No L42S504StandAssy ...