Hitachi Ultrastar 15K450 (FC-AL) Hard Disk Drive Specification
343
21.21.4.3 Recovered Drive Error
The Initiator should log the error as soft with the recovery level.
21.21.4.4 Drive Not Ready
The initiator should do the following:
1. Issue a
Start Stop Unit (1B)
command.
2. Verify that the drive comes ready within the time specified in Section 4.5.2, “Drive ready time” on page 13.
3. If the drive fails to come ready within the specified time, service the drive using the service guidelines specified in Sec-
tion 21.21.1, “Drive Service Strategy” on page 339.
4. Retry the failing command.
a. If the failing command completes with
Good Statu
s, log the error as recovered.
b. If the failing command completes with Not Ready sense, verify there is no outside cause (for example, the power
supply). Then service the drive using the service guidelines specified in Section 21.21.1, “Drive Service Strategy”
on page 339.
21.21.4.5 No Defect Spare
Three conditions can cause this error:
1. When the
Reassign Blocks (07)
command is issued and there are no spares available for the Drive to use for the reloca-
tion requested.
2. When the Glist is full and the sector to be reassigned cannot be added.
3. During a format operation, there was not enough space available to fulfill the spare requirement (Dlist is too large).
Service the Drive following Section 21.21.1, “Drive Service Strategy” on page 339.
21.21.4.6 Degraded Mode
Refer to Section 21.6.9, “Degraded Mode” on page 320, for the definition of this state. There are three causes for entering
degraded mode. In all cases the Sense Key is
Not Ready
. The causes are the following:
1. Sense Code/Qualifier of
Logical Unit Not Ready
,
initializing command required
. The spindle motor not spinning or not
at the proper speed. This may not be an error condition. The initiator should issue a
Unit start (1B)
command to start
the spindle motor. If the Drive fails to come ready in the time specified in Section 21.20, “Command Time out Limits”
on page 337, service the drive using the service guideline recommended in Section 21.21.1, “Drive Service Strategy”
on page 339.
2. Sense Code/Qualifier of
Diagnostic Failur
e. Failure of a Send Diagnostic self test, a start up sequence, or other internal
target failures.
- Failure of a send diagnostic self test or a start up sequence.
This failure is the result of the diagnostics that are executed during power on or when the
Send Diagnostic (1D)
com-
mand is executed detecting a failure. As with the RAM code not loaded and the configuration data not loaded, the
recovery is either a power cycle or issuing the
Send Diagnostic (1D)
command with the self test bit set active.
Recovery for a failed Send Diagnostic (1D) is achieved in one of the following ways:
Executing the Send Diagnostic (1D) command
Power cycling the drive
If the failure repeats, service the drive using the service guideline recommended in Section 21.21.1, “Drive Service
Strategy” on page 339.
Recovery for a failed power up sequence is achieved in one of the following ways:
Issuing a Unit start (1B) command
Power cycling the drive.
If the failure repeats, service the drive using the service guideline recommended in Section 21.21.1, “Drive Service
Strategy” on page 339.
Summary of Contents for Ultrastar 15K450
Page 18: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 2 ...
Page 20: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 4 ...
Page 22: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 6 ...
Page 30: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 14 ...
Page 32: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 16 ...
Page 34: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 18 ...
Page 44: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 28 ...
Page 60: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 44 ...
Page 62: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 46 ...
Page 65: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 49 Korea MIC Taiwan BSMI ...
Page 66: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 50 ...
Page 68: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 52 ...
Page 118: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 102 ...
Page 130: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 114 ...
Page 180: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 164 ...
Page 299: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 283 ...
Page 322: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 306 ...
Page 324: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 308 ...
Page 387: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 371 ...
Page 392: ...Hitachi Ultrastar 15K450 FC AL Hard Disk Drive Specification 376 ...