--- 23 ---
Q6 What is the relationship between the upper limit of the chargeable temperature of the battery and of
the battery charger?
A6 Relationships are indicated in the following table:
EB 7S, EB 7B
EB 9S, EB 9B, EB 9M
EB 12S, EB 12B
EB 1220BL, EB 12M
EB 14S
EB 14B
EB 1820
EB 18B
EB 24B
EB 9H, EB 930H
EB 12H, EB1222HL,
EB 1230H,
EB 1230HL, EB 14H,
EB 1430H
EB 18H,
EB 1830H,
EB 2430H
UC 14YF2
UC 24YJ
55 ˚C
55 ˚C
55 ˚C
50 ˚C
50 ˚C
60 ˚C
60 ˚C
Charging
impossible
45 ˚C
Charging
impossible
UC 14YF
60 ˚C
60 ˚C
Charging
impossible
Charging
impossible
Charging
impossible
UC 12YF
60 ˚C
Charging
impossible
Charging
impossible
Charging
impossible
Charging
impossible
UC 12YD
60 ˚C
Charging
impossible
Charging
impossible
Charging
impossible
Charging
impossible
UC 12YB
60 ˚C
Charging
impossible
Charging
impossible
Charging
impossible
Charging
impossible
UC 12Y
40 ˚C
Charging
impossible
Charging
impossible
Charging
impossible
Charging
impossible
UC 12YA
40 ˚C
Charging
impossible
Charging
impossible
Charging
impossible
Charging
impossible
Ni-MH battery
Ni-Cd battery
UC 24YC
60 ˚C
60 ˚C
60 ˚C
45 ˚C
45 ˚C
UC 24YF
60 ˚C
60 ˚C
60 ˚C
45 ˚C
45 ˚C