![Hitachi Summit RAC-60YH5 Service Manual Download Page 32](http://html.mh-extra.com/html/hitachi/summit-rac-60yh5/summit-rac-60yh5_service-manual_2139443032.webp)
– 30 –
MAIN PARTS COMPONENT
THERMOSTAT
Thermostat Specifications
FAN MOTOR
Fan Motor Specifications
CONNECTION
TEMPERATURE
°
C (
°
F)
INDICATION
16
INDICATION
24
INDICATION
32
MODEL
RAS-60YH5/RAC-60YH5
THERMOSTAT MODEL
IC
OPERATION MODE
COOL
HEAT
ON
15.6 (60.1)
20.0 (68.0)
OFF
15.3 (59.5)
20.7 (69.3)
ON
23.6 (74.5)
28.0 (82.4)
OFF
23.3 (73.9)
28.7 83.7)
ON
31.6 (88.9)
36.0 (96.8)
OFF
31.3 (88.3)
36.7 (98.1)
M
RED
BLK
WHT
YEL
BLU
35V
5V
0V
0 ~ 5V
FG
MODEL
RAS-60YH5
POWER SOURCE
DC: 0 ~ 35V
DC360V
OUTPUT
23W
40W
(Control circuit built in)
BLU : BLUE
YEL : YELLOW
BRN : BROWN
WHT : WHITE
GRY : GRAY
ORN : ORANGE
GRN : GREEN
RED : RED
BLK : BLACK
PNK : PINK
VIO : VIOLET
RED
360V
BLK
0V
WHT
15V
M
YEL
0~6V
BLU
0~15V
RAC-60YH5