background image

– 20 –

MAINTENANCE

Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,
stop operation and switch off the power supply.

1.   AIR FILTER

Clean the air filter, as it removes dust inside the room. In case the air filter is full of dust, the air flow
will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to clean the
filter following the procedure below.

!

CAUTION

1

2

3

!

CAUTION

PROCEDURE

Open the front panel and remove the filter

Gently lift and remove the air cleansing and
deodorizing filter from the air filter frame.

Vacuum dust from the air filter and air cleansing
and deodorizing filter using vacuum cleaner. If
there is too much dust, rinse under running tap
water and gently brush it with soft bristle brush.
Allow filters to dry in shade.

Re-insert the air cleansing and deodorizing
filter to the filter frame. Set the filter with
“FRONT” mark facing front, and slot them into
the original state.

After attaching the filters, push the front panel
at three arrow portions as shown in figure
and close it.

Do not wash with hot water at more than 40

°

C. The filter may shrink.

When washing it, shake off moisture completely and dry it in the shade; do not expose it directly to
the sun. The filter may shrink.

Do not use detergent on the air cleansing and deodorizing filter as some detergent may deteriorate
the filter electrostatic performance.

NOTE:

Air cleansing and deodorizing filter should be cleaned every month or sooner if noticeable loading
occurs. When used overtime, it may loose its deodorizing function. For maximum performance, it is
recommended to replace it every 3-6 months depending on application requirements.

Summary of Contents for Summit RAC-60YH5

Page 1: ... di istruzioni Pag 73 96 Per garantire la migliore prestazione e la più lunga durataleggere attentamente e al completo le seguanti istruzioni Manual de instrucciones Página 97 120 Para obtener el mejor funcionamiento y asegurar años de uso libre de problemas lea cuidadosamente este manual de instrucciones Manual de instruções Página 121 144 A fim de obter um bom funcionamento e de garantir uma uti...

Page 2: ...of electric shock exists Do not install the unit near a location where there is flammable gas The outdoor unit may catch fire if flammable gas leaks around it Please ensure smooth flow of water when installing the drain hose CAUTION PRECAUTIONS DURING SHIFTING OR MAINTENANCE Should abnormal situation arises like burning smell please stop operating the unit and turn off the circuit breaker Contact ...

Page 3: ... water will condense on the air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved This appliance is not intend...

Page 4: ...er Send out operation signal to the indoor unit So as to operate the whole unit Refer page 6 Drain pipe Condensed water drain to outside Connecting cord and insulation pipe for piping Air inlet Back and Left side Air outlet WIDTH mm 1030 850 MODEL RAS 60YH5 RAC 60YH5 HEIGHT mm 295 650 DEPTH mm 191 298 MODEL NAME AND DIMENSIONS OUTDOOR UNIT CAUTION When heating operation drain or defrosted water fl...

Page 5: ...bout 200 hours the FILTER lamp lights to indicate that it is time to clean the filter The lamp goes out when the AUTO SWING button is pressed while the device is on STANDBY MODE OPERATION LAMP This lamp lights during operation The OPERATION LAMP flashes in the following cases during heating 1 During preheating For about 2 3 minutes after starting up 2 During defrosting Defrosting will be performed...

Page 6: ...PERATURE buttons Use these buttons to raise or lower the temperature setting Keep pressed and the value will change more quickly TIME button Use this button to set and check the time and date RESET buttons FUNCTION selector Use this button to select the operating mode Every time you press it the mode will change from AUTO to HEAT to DEHUMIDIFY to COOL and to FAN cyclically FAN SPEED selector This ...

Page 7: ...cessary by maximum of 3 C Press the temperature button and the temperature setting will change by 1 C each time The preset temperature and the actual room temperature may vary somewhat depending on conditions The display does not indicate the preset temperature in the AUTO mode If you change the setting the indoor unit will produce a beep 1 C RESET Press the FAN SPEED button AUTO and LOW is availa...

Page 8: ... first and varies to MED or LOW automatically when the preset temperature has been reached HI Economical as the room will become warm quickly But you may feel a chill at the beginning MED Fan speed slow LOW Fan speed slower Set the desired room temperature with the TEMPERATURE buttons the display indicates the setting The temperature setting and the actual room temperature may vary somewhat depend...

Page 9: ...he temperature setting The function will stop the indoor unit will stop emitting air as soon as the room temperature becomes lower than the setting temperature Set the desired room temperature with the TEMPERATURE button the display indicates the setting The range of 20 26 C is recommended as the room temperature for dehumidifying Press the START STOP button Dehumidifying operation starts with a b...

Page 10: ...ED Fan speed slow LOW Fan speed slower Set the desired room temperature with the TEMPERATURE button the display indicates the setting The temperature setting and the actual room temperature may vary some how depending on conditions Press the START STOP button Cooling operation starts with a beep Press the button again to stop operation The cooling function does not start if the temperature setting...

Page 11: ... and setting temperature is large fan starts to run at HI speed After room temperature reaches the preset temperature the cooling operation which changes the fan speed and room temperature to obtain optimum conditions for natural healthful cooling will be performed For the cooling operation FAN OPERATION You can use the device simply as an air circulator Use this function to dry the interior of th...

Page 12: ...EL button The RESERVED sign goes out with a beep and the TIMER lamp turns off on the indoor unit 1 Set the current month and day with the TIMER control button 1 Press the OFF TIMER button The OFF mark blinks on the display 1 Press the ON TIMER button the ON mark blinks on the display 2 Set the turn off time with the TIMER control button Press the RESERVE button 3 Press the ON TIMER button so that ...

Page 13: ...me with the TIMER control button The setting of turn off time is now complete Example The device will turn off at 11 00p m Example The device will turn on at 7 00 a m The setting of the turn on time is now complete 4Set the turn on time with the TIMER control button 5 Point the signal window of the remote controller toward the indoor unit and press the RESERVE button The ON mark starts lighting in...

Page 14: ... 2 Press the SLEEP button and set the sleep timer The device will be turned off by the sleep timer and turned on by on timer How to Cancel Reservation Point the signal window of the remote controller toward the indoor unit and press the CANCEL button The RESERVED sign goes out with a beep and the TIMER lamp turns off on the indoor unit For heating In this case the device will turn off in 2 hours a...

Page 15: ...al air deflector within the adjusting range shown on the right When the operation is stopped the horizontal air deflector moves and stops at the position where the air outlet closes When cooling dehumidifying When heating CAUTION In Cooling operation do not keep the horizontal air deflector swinging for a long time Some dew may form on the horizontal air deflector and dew may drop RESET Adjustment...

Page 16: ...e old batteries 2 Install the new batteries The direction of the batteries should match the marks in the case 1 Do not use new and old batteries or different kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 or 3 months CAUTION Push and pull to the direction of arrow ...

Page 17: ...her with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty air filter will reduce the air volume and the cooling efficiency To prevent from wasting electric energy please clean the filter every 2 weeks Please pay attention to the room temperature and air flow direction when operating the unit for baby children and o...

Page 18: ...e used for a long period of time please switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 8W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket OFF Interference From Electrical Products Caution To avoid noise interfe...

Page 19: ...face written FRONT is facing front After attaching the filters push the front panel at three arrow portion as shown in figure and close it Do not bend the air cleansing and deodorizing filter as it may cause damage to the structure In case of removing the air cleansing and deodorizing filters please follow the above procedures The cooling capacity is slightly weakened and the cooling speed becomes...

Page 20: ...gently brush it with soft bristle brush Allow filters to dry in shade Re insert the air cleansing and deodorizing filter to the filter frame Set the filter with FRONT mark facing front and slot them into the original state After attaching the filters push the front panel at three arrow portions as shown in figure and close it Do not wash with hot water at more than 40 C The filter may shrink When ...

Page 21: ... the front panel with both hands to detach and attach it CAUTION Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit Never use hot water above 40 C benzine gasoline acid thinner or a brush because they will damage the plastic surface and the coating Removing the Front Panel Arm When the front panel is fully opened with both hands push the right ar...

Page 22: ...QUALIFIED SERVICE PERSONAL EITHER EVERY HALF YEARLY OR YEARLY CONTACT YOUR SALES AGENT OR SERVICE SHOP Is the earth line disconnected or broken Is the mounting frame seriously affected by rust and is the outdoor unit tilted or unstable Is the plug of power line firmly plugged into the socket Please ensure no loose contact between them Air Blow Cleaning and maintenance must be carried out only by q...

Page 23: ...lowing noise of refrigerant in the refrigerating cycle 2 Slight rubbing noise from the fan casing which is cooled and then gradually warmed as operation stops The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the air filter and the evaporator regularly must be cleaned to reduce the odor Please co...

Page 24: ...ly Companies are to be observed Minimum Maximum Minimum Maximum Indoor Dry bulb C 21 32 20 27 Wet bulb C 15 23 12 19 Outdoor Dry bulb C 21 43 2 21 Wet bulb C 15 26 1 15 Note Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21 C 70 F The recommended maximum and minimum operating temperatures of the hot and cold sides should be as below Cooling Heatin...

Reviews: