SINELINK24G
20
2-5 Connect to LAN equipments
This product complies with IEEE802.3af. It can be connected with LAN equipments,
such as Switching HUB, through PoE supply apparatus. (Follow the instruction below)
LAN cable
=Distance to Switching HUB should be less than 100m.
=LAN cable should be straight cable.
(In case Switching HUB is “Auto MDI/MDI-X” applied, it can be connected with
cross cable)
Switching HUB
=100BASE-TX(100Mbps, Full duplex)
NOTE: This product does not support 10Mbps or Semi duplex communication.
=Connection port setting should be “Auto Negotiation” or 100Mbps Fixed Full
duplex.
*NOTE: This product does not have filtering function by MAC address, etc.
In case necessary, Filtering must be done at LAN equipments of Switching HUB side.
2-6 Confirm the RF status
RF status can be confirmed through WWW browser of the connected tool (PC)
Please refer to item 3-3(3) below.
If the “Distance” or “Rx level” does not show proper level, it might be possible that
the Antenna direction is not settled properly, or any obstructs is blocking.