The electric expansion valve is driven by DC 12V. Power is supplied to 1 or 2 phases of 4-phase winding
to switch magnetic pole of winding in order to control opening degree.
●
Relationship between power switching direction of phase and open/close direction is shown below.
When power is supplied, voltages at pins 4 to 1 of CN15~CN17 are about 0.9V; they are about 12V
when no power is supplied. When power is reset, initialization is performed for 10 or 20 seconds.
During initialization, measure all voltages at pins 4 to 1 of CN15~CN17 using mutimeter. If there is any
pin with voltage that has not changed from around 0.9V or 12V, expansion valve or microcomputer is
defective.
●
Fig. 11-2 shows logic waveform when expansion valve is operating.
11.
Electric expansion valve
Pin
Drive status
Lear
wire
1
ON
OFF
OFF
OFF
Pin No.
12V
0.9V
200ms
75ms
50ms
42, 38
41, 37
40, 36
39, 35
ON
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
2
3
4
5
6
7
8
White
Blue
Operation mode
VALVE CLOSE
VALVE OPEN
1
8
2
7
3
6
4
5
5
4
6
3
7
2
8
1
Yellow
Orange
phase No.
4
3
2
1
Table 11-2
Fig. 11-2
Table 11-1
With expansion valve control, opening degree is adjusted to stabilize target temperature, by detecting
temperature of compressor head.
The period of control is about once per 20 seconds, and output a few pulses.
*
For RAM-65QH5 only.
Summary of Contents for RAM-55QH5
Page 31: ... 30 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 65QH5 ...
Page 37: ...CIRCUIT DIAGRAM MODEL RAM 55QH5 39 L C023 C022 C002 C001 C025 C024 N ...
Page 38: ...CIRCUIT DIAGRAM MODEL RAM 65QH5 41 L C023 C022 C002 C001 C025 C024 N ...
Page 41: ... 45 ...
Page 46: ... 51 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Page 47: ... 53 ...
Page 48: ... 55 ...
Page 49: ... 57 ...
Page 50: ... 59 ...
Page 68: ... 77 5A ...
Page 75: ... 84 ...
Page 76: ... 85 5 Reversing valve control circuit Fig 5 1 ...
Page 91: ... 103 ...
Page 92: ... 104 ...
Page 98: ... 110 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Page 99: ... 111 ...
Page 100: ... 112 ...
Page 102: ... 114 three three inlet 3 Cut off the three pipes at the side and bottom of Reversing valve ...
Page 103: ... 115 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 55QH5 MODEL RAM 65QH5 ...
Page 108: ...HITACHI PM NO 0312E Printed in Malaysia RAM 55QH5 RAM 65QH5 ...