Hitachi RAK-AJ10PCASV Installation & Operation Manual Download Page 2

1

1

MODE

ON/OFF

FAN

TURBO

TEMP

MUTE

LIGHT

SLEEP

TIMER

ON

ECO

IFEEL

CLOCK

CLEAN

TIMER

OFF

Used to set or cancel Economy Mode operation.

Used to set the CLEAN function.

The remote controller transmits signals  to the system.

Remote controller

1

2

3

13

4 5

6

12

11

7

8

9

10

    SWING BUTTON

FAN BUTTON

ROOM TEMPERATURE
SETTING BUTTONS

SLEEP BUTTON

LIGHT BUTTON

CLOCK BUTTON

ON/OFF BUTTON

        TURBO BUTTON

MODE BUTTON

TIMER ON/OFF BUTTON

Used to stop or start vertical adjustment 
louver swinging and set the desired up/down
airflow direction.

Used to select fan speed in sequence auto, high, medium or low.

Used to set or cancel Sleep Mode operation.

When you press this button, all the display of 
indoor unit will be closed. 

Used to set the current time.

Used to start or stop the fast cooling.(Fast cooling operates at high 

o

fan speed with 16 C set temp automatically).

 

The appliance will be started when it is energized or will be 
stopped when it is  in operation, if you press this button.

Press this button to select the operation mode.

Used to set or cancel the timer operation.

Remote controller

Indication symbols on LCD:

Note: Each mode and relevant function will be further specified in following pages. 

Signal transmit.

Dry indicator

Fan only indicator

Heating indicator

Cooling indicator

Higher fan speed

High fan speed

Medium fan speed 
Low fan speed

Lower fan speed

Display temperature

Display set timer

Display current time

Auto fan speed

Smart  indicator

ON

 OFF

Used to adjust  the room temperature and the timer, also real time.

Sleep indicator

16

15

MUTE BUTTON

Press it once,the MUTE

 

function will be started. 

Press it again, the MUTE  function will be shut off.

17

15

IFEEL BUTTON

Used to set IFEEL mode operation. Press it once, 
the IFEEL function will be started. Press it again, 
the IFEEL function will be shut off. 
If the IFEEL function can't be shut off, please try
to press this button about 5 seconds.
Advice to put the remote controller in the place
where the indoor unit receive signal easily.
Advice to cancel the IFEEL mode so as to save
energy when stopping the air conditioner.

   ECO BUTTON 

   CLEAN BUTTON 

14

Used to stop or start Horizontal adjustment 
louver swinging and set the desired left/right
airflow direction.

   SWING BUTTON 

   

  indicator

Mute

Economy  indicator

Ifeel

Lock

Nanoe  indicator

Turbo indicator

Airflow up and down

 

indicator

Airflow left and right

 

indicator

15

10

13

3

1

2

6

5

4

17

11

12

9

14

7

16

8

LOCK

Press them together for 3 seconds to start or stop 

.

LOCK

operation

+

12

11

Summary of Contents for RAK-AJ10PCASV

Page 1: ...HI2022480HA INSTALLATION OPERATION MANUAL MODEL RAK AJ10PCASV RAC AJ10PCASV RAK AJ13PCASV RAC AJ13PCASV RAK AJ18PCASV RAC AJ18PCASV RAK AJ24PCASV RAC AJ24PCASV ...

Page 2: ...ion will be further specified in following pages Signal transmit Dry indicator Fan only indicator Heating indicator Cooling indicator Higher fan speed High fan speed Medium fan speed Low fan speed Lower fan speed Display temperature Display set timer Display current time Auto fan speed Smart indicator ON OFF Used to adjust the room temperature and the timer also real time Sleep indicator 16 15 MUT...

Page 3: ...le TEMP Airflow direction control Vertical airflow Horizontal airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit The direction of airflow can be also adjusted to your own requirement by pressing the SWING button of the remote controller Operation mode Direction of airflow COOLING DRY HEATING FAN ONLY horizontal downward Do not turn ...

Page 4: ... it is convenient to install and well ventilated 2 Avoid installing it where flammable gas could leak 3 Keep the required distance apart from the wall The pipe length between indoor and outdoor unit should be not more than 5 meters in factory default status but it can go up to maximum 15 meters with additional refrigerant charge 6 Keep the outdoor unit away from greasy dirt vulcanization gas exit ...

Page 5: ...t pipes power Cord and drain pipe should be thermal insulated and fixed onto the back of the unit with a pipe fixer A Insert the pipe fixer to the slot B Press to hook the pipe fixer onto the base Base Base Base Pipe fixer Pipe fixer Hook here Insert here drain hose drain hose large pipe large pipe small pipe small pipe Piping Connection If you don t hear the exhaust noise please contact with the ...

Page 6: ... obtaining access to terminals all supply circuits must be disconnected Make sure that the color of the wires in the outdoor unit and terminal No are the same as those of the indoor unit the details please refer to the wiring diagram which is near the terminal inside the unit Cable Specifications Outdoor unit installation 1 Install Drain Port and Drain Hose for heat pump model only Drain hose prep...

Page 7: ...fter using it for about 100 hours Protection Operating condition note The protective device maybe trip and stop the appliance in the cases listed below The temperature of some products is allowed beyond the range In specific situation please consult the merchant If the air conditioner runs in COOLING or DRY mode withdoor or window opened for a long time when relative humidity is above 80 dew may d...

Page 8: ...The unit is shifting from heating mode to defrost The indicator will lights off within ten minutes and returns to heating mode The symbols may be different from these models but the functions are similar Example 8 1 2 3 4 Display introduction NO Display Introduction 7 9 11 12 13 14 1 5 8 6 3 4 10 2 Temperature indicator Display set temperature It shows FC after 200 hours of usage as reminder to cl...