SPECIFICATIONS FOR INDOOR UNITS COMBINATIONS
TYPE
CEILING CASSETTE TYPE DC INVERTER QUADRUPLE
SYSTEM MULTI COOLING AND HEATING
MODEL
INDOOR UNIT
OUTDOOR UNIT
TOTAL INPUT (W)
EER (B.T.U./hW)
TOTAL AMPERES (A)
POWER FACTOR (%)
SOUND LEVEL (INDOOR)
AIR FLOW VOLUME (Hi)
TOTAL INPUT (W)
EER (B.T.U./hW)
TOTAL AMPERES (A)
POWER FACTOR (%)
SOUND LEVEL (OUTDOOR)
TOTAL INPUT (W)
EER (B.T.U./hW)
TOTAL AMPERES (A)
POWER FACTOR (%)
SOUND LEVEL (INDOOR)
AIR FLOW VOLUME (Hi)
TOTAL INPUT (W)
EER (B.T.U./hW)
TOTAL AMPERES (A)
POWER FACTOR (%)
SOUND LEVEL (OUTDOOR)
RAI-25NH5
RAI-35NH5
RAM-40QH5
1ø, 220V-240V, 50Hz
16
PHASE/VOLTAGE/FREQUENCY
CIRCUIT AMPERES TO CONNECT (A)
CAPACITY (kW)
(B.T.U./h)
CAPACITY (kW)
(B.T.U./h)
CAPACITY (kW)
(B.T.U./h)
CAPACITY (kW)
(B.T.U./h)
AIR DEFLECTORS
FAN SPEED
LINE CORD
REMOTE CONTROL SWITCH
MAXIMUM LENGTH OF PIPING
STANDARD
COOLING
(ONE UNIT)
COOLING
(TWO UNITS)
HEATING
(ONE UNIT)
HEATING
(TWO UNITS)
MODEL
PACKING
(mm)
GROSSWEIGHT (kg)
FLARENUTSIZE (SMALL/LARGE)
W
H
D
cu.ft.
2.50 (1.00 ~ 3.00)
8540 (3412~10236)
750 (200-880)
11.39
3.44 ~ 3.16
99
35
8.5m
3
/min
3.50 (1.00 ~ 4.00)
11950 (3412~13660)
1090 (200-1300)
10.96
5.00 ~ 4.59
99
39
10.8m
3
/min
4.00 (1.50 ~ 4.50)
13660 (5126~15367)
1245 (200-1800)
10.97
5.72 ~ 5.24
99
49
3.40 (1.10 ~ 4.40)
11610 (3761~15026)
870 (200-1120)
13.34
3.99 ~ 3.66
99
36
8.5m
3
/min
4.20 (1.10 ~ 5.00)
14340 (3761~17070)
1080 (200-1300)
13.28
4.96 ~ 4.55
99
40
10.8m
3
/min
5.00 (1.50 ~ 5.60)
17070 (5126~19122)
1350 (200-1780)
12.64
6.20 ~ 5.68
99
51
YES (AUTO SWING)
3
YES (AUTO SWING)
3
NOT PROVIDED (POWER CORD SHOULD BE PREPARED AND
CONNECTED TO OUTDOOR UNIT WHEN INSTALLED)
YES (WIRELESS)
YES (WIRELESS)
MAX. 35m (TWO UNITS TOTAL)
CE (EMC&LVD)
RAI-25NH5
760
395
706
7.48
25
6.35/9.52D
RAI-35NH5
760
395
706
7.48
25
6.35/9.52D
RAM-40QH5
905
633
394
8.27
43
6.35/9.52D, 6.35/9.52D
– 5 –
Summary of Contents for RAI-25NH5
Page 31: ... 29 MODEL RAI 25NH5 RAI 35NH5 WIRING DIAGRAM INDOOR UNIT ...
Page 33: ...CIRCUIT DIAGRAM MODEL RAI 25NH5 RAI 35NH5 33 ...
Page 36: ... 39 47 RAI 25NH5 RAI 35NH5 ...
Page 58: ... 68 CHECKING THE REMOTE CONTROLLER ...
Page 62: ...HITACHI PM NO 0271E Printed in Malaysia RAI 25NH5 RAI 35NH5 ...