Hitachi RAC-X10CZ Instruction Manual Download Page 5

– 5 –

ENGLISH

INDOOR UNIT INDICATORS

TEMPORARY SWITCH

Use this switch to start and stop when the remote controller does not work. [Use non-conductor stick
(example toothpick)]

By pressing the temporary switch, the operation is done in previously set operation mode.

When the operation is done using the temporary switch after the power source is turned off and turn on
again, the operation is done in automatic mode.

OPERATION INDICATOR

TEMPORARY
SWITCH

Press

Temporary Switch

Non-conductor Stick

TEMPORARY
SWITCH

FILTER LAMP

When the device is operated for a total of about 200
hours, the FILTER lamp lights to indicate that it is time
to clean the filter. The lamp goes out when the
“        (AUTO SWING)” button is pressed while the
device is on “STANDBY MODE”.

OPERATION LAMP

This lamp lights during operation.

TIMER LAMP

This lamp lights when the timer is working.

Summary of Contents for RAC-X10CZ

Page 1: ...Z RAC X10CZ OUTDOOR UNIT INDOOR UNIT RAS X10CZ HITACHI Instruction manual Page 1 24 To obtain the best performance please read this instruction manual completely Arahan pengendalian Muka surat 25 48 Untuk mendapatkan prestasi yang tinggi sila baca arahan ini sepenuhnya RAC X10CZ ...

Page 2: ...lectric shock exists Do not install the unit near a location where there is flammable gas The outdoor unit may catch fire if flammable gas leaks around it Please ensure smooth flow of water when installing the drain hose CAUTION PRECAUTIONS DURING SHIFTING OR MAINTENANCE Should abnormal situation arises like burning smell please stop operating the unit and turn off the circuit breaker Contact your...

Page 3: ...e cooling capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved This appliance is not intended for use by young children unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely Young children should be supervised to ensure that they do not play wit...

Page 4: ...ntal deflector Vertical deflector Air Outlet Refer page 14 Remote controller Send out operation signal to the indoor unit So as to operate the whole unit Refer page 6 OUTDOOR UNIT Drain pipe Condensed water drain to outside Connecting cord and insulation pipe for piping Air inlet Back Left side Air outlet WIDTH mm 780 700 MODEL RAS X10CZ RAC X10CZ HEIGHT mm 280 468 DEPTH mm 220 258 MODEL NAME AND ...

Page 5: ...e power source is turned off and turn on again the operation is done in automatic mode OPERATION INDICATOR TEMPORARY SWITCH Press Temporary Switch Non conductor Stick TEMPORARY SWITCH FILTER LAMP When the device is operated for a total of about 200 hours the FILTER lamp lights to indicate that it is time to clean the filter The lamp goes out when the AUTO SWING button is pressed while the device i...

Page 6: ...ver faster and more comfortable air conditioning TO STOP button Press this button to stop operation only ONE TOUCH SILENT COOL button Use this button to set silent condition FAN SPEED selector This determines the fan speed Each time you press this button the intensity of circulation will change from AUTO to HI to MED to LOW to SILENT AUTO SWING button Controls the angle of the horizontal air defle...

Page 7: ...isplay indicates the setting AUTO The FAN SPEED is HI at first and varies to MED or LOW automatically when the preset temperature has been reached HI Hi fan speed mode MED Medium fan speed mode LOW Low fan speed mode SILENT Silent fan speed mode Set the desired room temperature with the TEMPERATURE button the display indicates the setting The range of 25 28 C is recommended as the room temperature...

Page 8: ...ure setting The function will stop the indoor unit will stop emitting air as soon as the room temperature becomes lower than the setting temperature You might feel a bit colder in dehumidifying operation As the settings are stored in memory in the remote controller you only have to press the DEHUMIDIFY button next time Set the desired room temperature with the TEMPERATURE button the display indica...

Page 9: ...1 CANCELLATION of SUPER SILENT Operation Cancel Condition Operation mode after cancel Press button Sleeping timer time is up Stop operation Press SPEED COOL button SPEED COOL operation Press button Next fan speed operation NOTE Under ONE TOUCH SILENT COOL operation and quiet environment phenomena like flowing noise of refrigerant in the refrigerating cycle may occur but this is normal for the oper...

Page 10: ...ontrol button to set to the desired temperature As the settings are stored in memory in the remote controller you only have to press the CIRCULATION button next time 1 3 Press the STOP button to stop operation STOP 2 Circulation Function During circulation operation compressor does not run and there is no cooling operation with only indoor fan running When the setting temperature is higher than ro...

Page 11: ...l operation SPEED COOL When pressed SPEED COOL button Selected FAN SPEED Default Angle θ FAN SPEED Angle θ HI COOLING OPERATION MED LOW SILENT AUTO LOW SILENT HI MED LOW SILENT AUTO DEHUMIDIFYING OPERATION HI HI HI HI HI LOW LOW HI HI HI HI HI 55 60 CIRCULATION OPERATION 10 35 35 35 θ Horizontal Deflector Angle During circulation operation compressor does not run and there is no cooling operation ...

Page 12: ...tion will be displayed on the remote controller The TIMER lamp lights with a beep from the indoor unit SLEEP Explanation of the sleep timer The device will control the FAN SPEED and room temperature automatically so as to be quiet and good for people s health You can not set other timer during sleep timer operation After sleep timer time is up and when press sleep button again the sleep timer will...

Page 13: ...he ON Button Setting time will change according to the below sequence ON Timer Reservation 1 2 3 9 10 11 12 1 hour interval CANCEL OFF TIMER Operation will start for setting temperature at setting time The starting time may different depend on the room temperature and set temperature ...

Page 14: ...efore the deflector starts to move Use the horizontal air deflector within the adjusting range shown on the right When the operation is stopped the horizontal air deflector moves and stops at the position where the air outlet closes CAUTION In Cooling operation do not keep the horizontal air deflector swinging for a long time Some dew may form on the horizontal air deflector and dew may drop Adjus...

Page 15: ... or different kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 or 3 months 3 Use high quality and high performance AAA batteries to avoid short operating life and electrolyte leakages CAUTION When using the remote control if there is no response from the air conditioner unit and or the remote control has fading and dim displays the batteries in t...

Page 16: ...with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty air filter will reduce the air volume and the cooling efficiency To prevent from wasting electric energy please clean the filter every 2 weeks Please pay attention to the room temperature and air flow direction when operating the unit for baby children and old f...

Page 17: ...to be used for a long period of time please switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 8W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket OFF Interference From Electrical Products Caution To avoid noise int...

Page 18: ...t Cleaning and maintenance must be carried out when filter lamp lights Before cleaning stop operation and switch off the power supply CAUTION CAUTION Do not bend the air purifying filter as it may cause damage to the structure NOTE In case of removing the air purifying filters please follow the above procedures The cooling capacity is slightly weakened and the cooling speed becomes slower when the...

Page 19: ...oft bristle brush Allow filters to dry in shade 3 Re insert the air purifying filter to the filter frame Set the Pre filter with FRONT mark facing front and slot them into the original state After attaching the Pre filters push the front panel at three arrow portions as shown in figure and close it CAUTION Do not wash with hot water at more than 40 C The filters may shrink When washing it shake of...

Page 20: ...ojections of the left and right arms into the Flanges in the unit and securely insert them into the holes HITACHI Projection Flange Hole Remove the front panel and wash with clean water Wash it with a soft sponge After using neutral detergent wash thoroughly with clean water When front panel is not removed wipe it with a soft dry cloth Wipe the remote controller thoroughly with a soft dry cloth Wi...

Page 21: ...on the mounting site of the unit Without a circuit breaker the danger of electric shock exists NOTE If the supply cord is damaged it must be replaced by the special cord obtainable at authorized service parts centers 1 2 3 REGULAR INSPECTION PLEASE CHECK THE FOLLOWING POINTS BY QUALIFIED SERVICE PERSONAL EITHER EVERY HALF YEARLY OR YEARLY CONTACT YOUR SALES AGENT OR SERVICE SHOP Is the earth line ...

Page 22: ...lowing noise of refrigerant in the refrigerating cycle 2 Slight rubbing noise from the fan casing which is cooled and then gradually warmed as operation stops The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the air filter and the evaporator regularly must be cleaned to reduce the odor Please co...

Page 23: ...ularly when the room light is dimmed a slight brightness fluctuation may occur This is of no consequence The conditions of the local Power Supply Companies are to be observed Minimum Maximum Indoor Dry bulb C 21 32 Wet bulb C 15 23 Outdoor Dry bulb C 21 43 Wet bulb C 15 26 Note Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21 C 70 F The recommend...

Page 24: ... 24 MEMO ...

Page 25: ... DALAM BILIK UNIT LUAR BILIK MODEL RAS X10CZ RAC X10CZ RAS X10CZ HITACHI Instruction manual Page 1 24 To obtain the best performance please read this instruction manual completely Arahan pengendalian Muka surat 25 48 Untuk mendapatkan prestasi yang tinggi sila baca arahan ini sepenuhnya RAC X10CZ ...

Page 26: ...karan mungkin berlaku Hubungi wakil jualan untuk membaiki kerosakan Membaiki kerosakan dengan sendiri boleh menyebabkan kejutan elektrik atau kebakaran Hubungilah wakil jualan jika anda hendak mengalihkan penyaman udara untuk dipasang di tempat lain Pengalihan dan pemasangan semula dengan sendiri yang tidak sempurna boleh mengakibatkan kejutan elektrik dan kebakaran Tali bekalan yang rosak mesti d...

Page 27: ...rta semasa pengawal aliran udara hala ke bawah atau pengawal aliran udara beroperasi secara automatik Jika tidak air akan terkondensasi pada pengawal aliran udara mendatar dan akan menitis ke bawah dan membasahi perkakas rumah Jika terdapat sumber haba yang melebihi kapasiti penyaman udara terdapat terlalu ramai orang atau menggunakan alat pemanasan suhu dalam bilik tidak akan mencapai suhu yang d...

Page 28: ...N UNTUK SISTEM PAIP LUBANG UDARA MASUK SEBELAH KIRI DI BELAKANG LUBANG UDARA KELUAR Mengeluarkan udara panas PRA PENAPIS Menghalang habuk masuk ke dalam unit dalam bilik Lihat mukasurat 43 PANEL DEPAN LAMPU PENANDA UNIT DALAM BILIK Menunjukkan keadaan operasi Lihat mukasurat 29 PENGAWAL ALIRAN UDARA MENDATAR DAN MENEGAK LUBANG UDARA KELUAR Lihat mukasurat 38 ALAT KAWALAN JAUH Memberi isyarat kepad...

Page 29: ...EMASA Lampu ini bernyala apabila menggunakan fungsi pemasa BAHAGIAN PENUNJUK UNIT DALAM BILIK BAHAGIAN OPERASI SUIS SEMENTARA SUIS SEMENTARA Tekan Suis sementara Kayu penebat SUIS SEMENTARA Suis ini digunakan apabila alat kawalan jauh tidak dapat beroperasi Gunakan kayu penebat contoh pencungkil gigi Setelah menyelaraskan suis sementara penyaman udara akan beroperasi dalam mode operasi yang terdah...

Page 30: ...NE TOUCH Gunakan butang ini untuk mengatur kedudukan senyap Pemilih KELAJUAN KIPAS Butang ini adalah untuk memilih kelajuan kipas Setiap kali anda menekan butang ini tekanan peredaran akan bertukar dari AUTO ke TINGGI ke SEDERHANA ke RENDAH ke SENYAP Butang PENYELARAS ARAH ALIRAN UDARA AUTOMATIK Menyelaras sudut arah aliran udara mendatar Butang SUHU Gunakan butang ini untuk menaik atau merendahka...

Page 31: ... akan bermula sebaik sahaja anda membuat tetapan suhu di bawah suhu semasa bilik berkenaan Tetapkan KELAJUAN KIPAS yang dikehendaki dengan butang KELAJUAN KIPAS paparan akan menunjukkan tetapan AUTO KELAJUAN KIPAS pada permulaan ialah TINGGI dan ia akan berubah kepada SEDERHANA atau RENDAH secara automatik apabila suhu tetapan dicapai TINGGI Mod kelajuan kipas tinggi SEDERHANA Mod kelajuan kipas s...

Page 32: ... pengeringan bermula dengan bunyi beep KELAJUAN KIPAS ditetapkan pada SENYAP atau RENDAH secara automatik Butang KELAJUAN KIPAS boleh digunakan untuk menukar antara SENYAP dan RENDAH sahaja 1 Fungsi Pengeringan Apabila suhu bilik adalah lebih tinggi daripada suhu tetapan Unit akan mengering dan mengurangkan suhu bilik kepada tahap yang telah ditetapkan Apabila suhu bilik lebih rendah daripada suhu...

Page 33: ...PEMBATALAN Operasi SENYAP SUPER Syarat pembatalan Mode operasi selepas pembatalan Tekan butang Pemasa tidur tamat Operasi Berhenti Tekan butang SEJUK PANTAS Operasi SEJUK PANTAS Operasi kelajuan kipas yang berikut Tekan butang NOTA Pada operasi PENDINGINAN SENYAP ONE TOUCH dan alam sekeliling yang senyap fenomena seperti bunyi aliran bahan pendingin dalam kitaran pendinginan akan berlaku tetapi in...

Page 34: ...yang diingini Tekan butang BERHENTI untuk menghentikan operasi Disebabkan tetapan telah disimpan di dalam memori di dalam alat kawalan jauh anda hanya perlu menekan butang PEREDARAN pada masa yang akan datang 2 1 3 BERHENTI Fungsi Peredaran Udara Semasa operasi peredaran udara kompressor tidak akan berfungsi dan tidak berlaku operasi penyejukan dengan kipas sahaja berfungsi Apabila suhu tetapan le...

Page 35: ...S Semasa menekan butang SEJUK PANTAS Pilih KELAJUAN KIPAS Sudut Tetapan θ KELAJUAN KIPAS Sudut θ TINGGI OPERASI PENDINGIANAN SEDERHANA RENDAH SENYAP AUTO RENDAH SENYAP OPERASI PENGERINGAN TINGGI RENDAH RENDAH 55 60 OPERASI PEREDARAN UDARA 10 35 35 35 θ Sudut Pengawal Arah Aliran Mendatar Semasa operasi peredaran udara kompressor berhenti dan tidak ada operasi penyejukan dengan hanya kipas unit dal...

Page 36: ...an jauh Lampu pemasa bernyala dengan bunyi beep daripada penyaman udara Penerangan pemasa tidur Unit akan mengawal KELAJUAN KIPAS dan suhu bilik secara automatik untuk mewujudkan suasana yang tenang dan baik untuk kesihatan Anda tidak boleh membuat tetapan pemasa yang lain semasa pemasa tidur beroperasi Selepas masa pemasa tidur telah tamat dan butang tidur ditekan semula pemasa tidur akan ditetap...

Page 37: ...g ON Penetapan masa akan berubah mengikut turutan di bawah setiap kali anda menekan butang HIDUPKAN Penyelarasan Pemasa Operasi akan bermula untuk penetapan suhu pada masa tertentu Masa permulaan mungkin boleh berubah bergantung kepada suhu bilik dan suhu yang ditetapkan 1 2 3 9 10 11 12 1 jam selang Pemasa OFF berhenti ...

Page 38: ...al itu akan bergerak semula selepas beberapa saat lebih kurang 6 saat Gunakan pengawal arah aliran udara pada sudut yang ditunjukkan Apabila operasi diberhentikan pengawal arah aliran udara bergerak dan berhenti di dalam posisi tertutup Penyelarasan arah aliran udara ke atas dan ke bawah Pengawal arah aliran udara mendatar dilaraskan secara automatik kepada sudut yang sesuai bagi operasi pengering...

Page 39: ...endek atau kebocoran elektroli PERKARA YANG PERLU DIAMBIL PERHATIAN BAGAIMANA MENUKAR BATERI ALAT KAWALAN JAUH Keluarkan penutup seperti yang ditunjukkan dalam gambarajah dan keluarkan bateri lama Pasangkan bateri baru Arah bateri mesti sepadan dengan tanda dalam kotak Semasa menggunakan alat kawalan jauh sekiranya tidak ada tindak balas daripada unit penghawa dingin atau paparan pada alat kawalan...

Page 40: ... bagi tempat yang menggunakan peralatan gas Penggunaan pemasa yang berkesan Sila gunakan pemasa secara berkesan Gunakan operasi OFF atau ON pada waktu malam dan bersesuaian dengan waktu bangun untuk mendapat suhu bilik yang selesa Jangan lupa membersihkan penapis udara Penapis udara yang tersumbat akan menghalang pergerakan udara serta mengurangkan kesan pendinginan Sila bersihkan penapis udara se...

Page 41: ...enggunakan penyaman udara untuk jangka masa panjang Jika tidak menggunakan unit dalam bilik bagi jangka masa panjang sila padamkan suis bekalan kuasa Jika suis bekalan kuasa dipasang walaupun unit dalam bilik tidak beroperasi tenaga elektrik akan dibazirkan dalam litar pengawal kira kira 8W Semasa berlakunya kilat Amaran Semasa berlakunya kilat hentikan operasi penyaman udara dan keluarkan plagnya...

Page 42: ...kan tanda FRONT menghala ke hadapan Setelah memasang penapis itu tekan panel depan mengikut 3 anak panah yang ditunjukkan dan tutup PERHATIAN Jangan bengkokkan penapis pembersih udara kerana ia akan mengakibatkan kerosakkan pada strukturnya NOTA Jika ingin menanggalkan penapis pembersih udara sila ikuti prosedur diatas Kapasiti penyejuk berkurang sedikit dan kecepatan penyejukan menjadi lebih lamb...

Page 43: ...dan berus perlahan dengan berus yang lembut Biarkan kering di tempat yang teduh Masukkan semula pra penapis ke rangka pra penapis Pastikan bahagian pra penapis yang bertanda FRONT menghala ke atas dan sorongkan pra penapis ke kedudukan asalnya Setelah memasang penapis itu tekan panel depan mengikut 3 anak panah yang ditunjukkan dan tutup NOTA Penapis pembersih udara hendaklah dibersihkan setiap bu...

Page 44: ...ngga HITACHI Tapak Lubang Penyangga Penyangga 2 MEMBERSIHKAN PANEL DEPAN Tanggalkan panel depan dan basuh dengan air bersih Gunakan span lembut Selepas membasuh dengan sabun bilas dengan air bersih Sekiranya panel depan tidak dibuka cuci dengan menggunakan kain basah Bersihkan alat kawalan jauh dengan menggunakan kain kering dan lembut Lapkan air sekeringnya Sekiranya air didapati pada bahagian pe...

Page 45: ...lah dipasang berhampiran dengan unit Tanpa litar pemutus boleh menyebabkan kemungkinan berlaku kejutan elektrik NOTA Sekiranya wayar didapati rosak ia mesti ditukarkan dengan wayar yang boleh didapati dari pusat servis barangan yang diiktiraf 1 2 3 Adakah dawai bumi tercabut atau terputus Adakah tapak unit luar bilik telah berkarat dengan serius dan kukuhkan unit luar bilik Adakah plag dimasukkan ...

Page 46: ...n normal setelah memeriksa perkara di atas sila beritahu wakil jualan tentang jenis unit kod penghasilan tarikh pemasangan dan masalah yang dihadapi Palam kuasa hendaklah menggunakan voltan yang disyorkan jika tidak unit akan rosak atau kapasiti yang ditetapkan tidak dapat dicapai Nota Semasa dalam operasi yang senyap atau penyaman udara telah dihentikan perkara berikut mungkin berlaku sekali kala...

Page 47: ...3 Luar Bangunan Bebuli Kering C 21 43 Bebuli Basah C 15 26 Nota Apabila suhu luar bilik dibawah 21 C 70 F elakkan daripada menggunakan penyaman udara untuk operasi kesejukan Suhu operasi maksimum dan minimum untuk bahagian sejuk dan panas adalah seperti berikut Produk ini telah diuji dan disahkan mengikut akta 89 336 EEC pemeriksaan sambungan arus elektromagnet dan 73 23 EEC pemeriksaan alatan ele...

Page 48: ... 48 MEMO ...

Reviews: