background image

– 1 –

ENGLISH

SPLIT TYPE AIR CONDITIONER

INDOOR UNIT/OUTDOOR UNIT

OUTDOOR UNIT

INDOOR UNIT

Instruction manual

 

Page 1~24

To obtain the best performance, please read this instruction manual completely.

Petunjuk Penggunaan

  

Halaman 25~48

Untuk mendapatkan kinerja terbaik, harap baca seluruh petunjuk penggunaan ini.

MODEL

RAS-SD10CB

(J)

 / RAC-SX10CB

(J)

RAS-SD13CB

(J)

 / RAC-SX13CB

(J)

RAS-SD10CB

(J)

RAS-SD13CB

(J)

RAC-SX10CB

(J)

RAC-SX13CB

(J)

RAS-SD10CB-J (EN1)   1

3/21/12   10:56 AM

Summary of Contents for RAC-SD10CCT

Page 1: ...Page 1 24 To obtain the best performance please read this instruction manual completely Petunjuk Penggunaan Halaman 25 48 Untuk mendapatkan kinerja terbaik harap baca seluruh petunjuk penggunaan ini MODEL RAS SD10CB J RAC SX10CB J RAS SD13CB J RAC SX13CB J RAS SD10CB J RAS SD13CB J RAC SX10CB J RAC SX13CB J ...

Page 2: ...all the unit near a location where there is ammable gas The outdoor unit may catch re if ammable gas leaks around it Please ensure smooth ow of water when installing the drain hose CAUTION Make sure to connect earth line Indicates the instructions that must be followed The sign in the gure indicates prohibition PRECAUTIONS DURING OPERATION Avoid an extended period of direct air ow for your health ...

Page 3: ...e cooling capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved This appliance is not intended for use by young children unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely Young children should be supervised to ensure that they do not play wit...

Page 4: ...ector Vertical de ector Air Outlet Refer page 15 Remote controller Send out operation signal to the indoor unit So as to operate the whole unit Refer page 6 OUTDOOR UNIT Drain pipe Condensed water drain to outside Connecting cord and insulation pipe for piping Air inlet Back Left side Air outlet WIDTH mm 790 700 MODEL RAS SD10CB J RAS SD13CB J RAC SX10CB J RAC SX13CB J HEIGHT mm 300 468 DEPTH mm 2...

Page 5: ...n again the operation is done in automatic mode OPERATION INDICATOR FILTER LAMP When the device is operated for a total of about 200 hours the FILTER lamp lights to indicate that it is time to clean the lter The lamp goes out when the AUTO SWING button is pressed while the device is on STANDBY MODE OPERATION LAMP This lamp lights during operation TIMER LAMP This lamp lights when the timer is worki...

Page 6: ...ter and more comfortable air conditioning or start operation TO STOP button Press this button to stop operation only ONE TOUCH SILENT button Use this button to set silent condition FAN SPEED selector This determines the fan speed Each time you press this button the intensity of circulation will change from AUTO to HI to MED to LOW to SILENT AUTO SWING button Controls the angle of the horizontal ai...

Page 7: ...n the display indicates the setting AUTO The FAN SPEED is HI at rst and varies to MED or LOW automatically when the preset temperature has been reached HI Hi fan speed mode MED Medium fan speed mode LOW Low fan speed mode SILENT Silent fan speed mode Set the desired room temperature with the TEMPERATURE button the display indicates the setting The range of 25 28 C is recommended as the room temper...

Page 8: ...ature setting The function will stop the indoor unit will stop emitting air as soon as the room temperature becomes lower than the setting temperature You might feel a bit colder in dehumidifying operation As the settings are stored in memory in the remote controller you only have to press the DEHUMIDIFY button next time Set the desired room temperature with the TEMPERATURE button the display indi...

Page 9: ...emperature control button to set to the desired temperature As the settings are stored in memory in the remote controller you only have to press the CIRCULATION button next time 1 3 Press the button to stop operation STOP 2 Circulation Function During circulation operation compressor does not run and there is no cooling operation with only indoor fan running When the setting temperature is higher ...

Page 10: ...ime usage After enter standby mode CONDITION 1 CONDITION 2 Operation Button Press or or Press or or Press or or again Press or or again Press or or again Press Press or or Press or or again Press Press or or Press or or again Note During rst time usage if Lamp is OFF it is not malfunction Press operation button or or to ON the Lamp ON OFF ON ON OFF OFF OFF ON OFF ON OFF Operation Button Lamp Lamp ...

Page 11: ...nit will continue to operate in cooling mode base on previous setting 1 CANCELLATION of ONE TOUCH SILENT Operation Cancel Condition Operation mode after cancel Press button Stop operation Press button POWERFUL operation Press button Press button NOTE Under ONE TOUCH SILENT operation and quiet environment phenomena like owing noise of refrigerant in the refrigerating cycle may occur but this is nor...

Page 12: ...ile unit will be in previous mode setting Temperature and fan speed will change to previous setting Air blow sound will be slightly high due to forced operation 1 NOTE 1 ON TIME setting POWERFUL operation will be a priority over the ON timer operation time CANCELLATION of POWERFUL Operation Cancel Condition Operation mode after cancel Press or SLEEP timer time is up Stop operation key press DEHUMI...

Page 13: ...LEEP button The timer information will be displayed on the remote controller The TIMER lamp lights with a beep from the indoor unit SLEEP Explanation of the sleep timer You can not set other timer during sleep timer operation After sleep timer time is up and when press sleep button again the sleep timer will be set as last setting Sleep timer is effective only once Press button to select the fan s...

Page 14: ...ton Setting time will change according to the below sequence ON Timer Reservation Operation will start for setting temperature at setting time The starting time may different depend on the room temperature and set temperature Press button to select the fan speed during timer operation ...

Page 15: ... before the de ector starts to move Use the horizontal air de ector within the adjusting range shown on the right When the operation is stopped the horizontal air de ector moves and stops at the position where the air outlet closes CAUTION In Cooling operation do not keep the horizontal air de ector swinging for a long time Some dew may form on the horizontal air de ector and dew may drop Adjustme...

Page 16: ...ifferent kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 or 3 months 3 Use high quality and high performance AAA batteries to avoid short operating life and electrolyte leakages CAUTION When using the remote control if there is no response from the air conditioner unit and or the remote control has fading and dim displays the batteries in the re...

Page 17: ...ogether with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty air lter will reduce the air volume and the cooling ef ciency To prevent from wasting electric energy please clean the lter every 2 weeks Please pay attention to the room temperature and air ow direction when operating the unit for baby children and old ...

Page 18: ...achieved When the indoor unit is not to be used for a long period of time please switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 5W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket OFF Interference From Electrica...

Page 19: ...d maintenance must be carried out when lter lamp lights Before cleaning stop operation and switch off the power supply CAUTION CAUTION Do not bend the air purifying lter as it may cause damage to the structure Please do not smell direct from source of lter NOTE In case of removing the air purifying lters please follow the above procedures The cooling capacity is slightly weakened and the cooling s...

Page 20: ... it with soft bristle brush Allow lters to dry in shade 3 Re insert the air purifying lter to the lter frame Set the Pre lter with FRONT mark facing front and slot them into the original state After attaching the Pre lters push the front panel at three arrow portions as shown in gure and close it CAUTION Do not wash with hot water at more than 40 C The lters may shrink When washing it shake off mo...

Page 21: ... Move the projections of the left and right arms into the Flanges in the unit and securely insert them into the holes Remove the front panel and wash with clean water Wash it with a soft sponge After using neutral detergent wash thoroughly with clean water When front panel is not removed wipe it with a soft dry cloth Wipe the remote controller thoroughly with a soft dry cloth Wipe the water thorou...

Page 22: ...ounting site of the unit Without a circuit breaker the danger of electric shock exists NOTE If the supply cord is damaged it must be replaced by the special cord obtainable at authorized service parts centers 1 2 3 REGULAR INSPECTION PLEASE CHECK THE FOLLOWING POINTS BY QUALIFIED SERVICE PERSONAL EITHER EVERY HALF YEARLY OR YEARLY CONTACT YOUR SALES AGENT OR SERVICE SHOP Is the earth line disconne...

Page 23: ...ght owing noise of refrigerant in the refrigerating cycle 2 Slight rubbing noise from the fan casing which is cooled and then gradually warmed as operation stops The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the air lter and the evaporator regularly must be cleaned to reduce the odor Please c...

Page 24: ...ns of the local Power Supply Companies are to be observed Minimum Maximum Indoor Dry bulb C 21 32 Wet bulb C 15 23 Outdoor Dry bulb C 21 43 Wet bulb C 15 26 Note Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21 C 70 F The recommended maximum and minimum operating temperatures of the hot and cold sides should be as below ...