– 13 –
The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the current room
temperature. The selected mode of operation will change when the room temperature varies. However the mode of operation
will not change when indoor unit connected to multi type outdoor unit.
■
Auto Restart Control
●
If there is a power failure, operation will be automatically restarted when the power is resumed with previous operation mode
and air
fl
ow direction.
(As the operation is not stopped by remote controller.)
●
If you intend not to continue the operation when the power is resumed, switch off the power supply.
When you switch on the circuit breaker, the operation will be automatically restarted with previous operation mode and air
fl
ow
direction.
Note: 1. If you do not require Auto Restart Control, please consult your sales agent or OFF by remote control.
2. Auto Restart Control is not available when Timer or Sleep Timer mode is set.
■
As the settings are stored in memory in the remote controller, you only
have to press the (START/STOP) button next time.
Press the FUNCTION selector so that the display indicates the (AUTO)
mode of operation.
●
When AUTO has been selected, the device will automatically determine
the mode of operation, HEAT, COOL or DEHUMIDIFY depending on
the current room temperature. However the mode of operation will
not change when indoor unit connected to multi type outdoor unit.
●
If the mode automatically selected by the unit is not satisfactory,
manually change the mode setting (heat, dehumidify, cool or fan).
Press the (START/STOP) button.
Operation starts with a beep.
Press the button again to stop operation.
You can raise or lower the temperature setting as necessary by maximum
of 3°C.
Press the temperature button and the temperature
setting will change by 1°C each time.
●
The preset temperature and the actual room temperature may vary
somewhat depending on conditions.
●
The display does not indicate the preset temperature in the AUTO mode.
If you change the setting, the indoor unit will produce a beep.
1
START
STOP
Press the (FAN SPEED) button, AUTO, LOW and SILENT is available.
Summary of Contents for RAC-60YH7A
Page 30: ... 29 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS 60YH7 ...
Page 31: ... 30 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC 60YH7A ...
Page 35: ...CIRCUIT DIAGRAM Remote Control 35 ...
Page 36: ... 37 CIRCUIT DIAGRAM MODEL RAS 60YH7 ...
Page 37: ... 39 CIRCUIT DIAGRAM MODEL RAC 60YH7A ...
Page 39: ... 42 MODEL RAC 60YH7A P W B MAIN ...
Page 40: ... 43 ...
Page 41: ... 44 BLOCK DIAGRAM MODEL RAS 60YH7 RAC 60YH7A ...
Page 42: ... 45 ...
Page 43: ... 47 ...
Page 44: ... 49 ...
Page 45: ... 51 ...
Page 46: ... 53 ...
Page 49: ... 59 REFRIGERATING CYCLE DIAGRAM MODEL RAS 60YH7 RAC 60YH7A ...
Page 51: ... 61 DESCRIPTION OF MAIN CIRCUIT OPERATION 1 Reset Circuit MODEL RAS 60YH7 ...
Page 52: ... 62 ...
Page 56: ... 66 DESCRIPTION OF MAIN CIRCUIT OPERATION 1 Power Circuit ...
Page 57: ... 67 ...
Page 58: ... 68 ...
Page 59: ... 69 ...
Page 60: ... 70 ...
Page 61: ... 71 ...
Page 62: ... 72 ...
Page 63: ... 73 ...
Page 64: ... 74 SERVICE CALL Q A ...
Page 65: ... 75 ...
Page 66: ... 76 ...
Page 67: ... 77 ...
Page 68: ... 78 TROUBLE SHOOTING ...
Page 69: ... 79 ...
Page 70: ... 80 ...
Page 71: ... 81 ...
Page 72: ... 82 ...
Page 75: ... 85 ...
Page 76: ... 86 ...
Page 77: ... 87 ...
Page 78: ... 88 ...
Page 79: ... 89 ...
Page 80: ... 90 ...
Page 81: ... 91 ...
Page 83: ... 93 ...
Page 84: ... 94 ...
Page 85: ... 95 6 126 6 7 1 02 ...
Page 86: ... 96 CHECKING THE REMOTE CONTROLLER ...
Page 87: ... 97 ...
Page 88: ... 98 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 60YH7 ...
Page 90: ... 100 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 60YH7A ...
Page 92: ...HITACHI PM NO 0508E Printed in Malaysia RAS 60YH7 RAC 60YH7A ...